SPE-TT. Tutorial Version Bruker BioSpin ; File: Tutorial 11 - SPE-TT; Version: ; By: Dr.

Size: px
Start display at page:

Download "SPE-TT. Tutorial Version 2009-08-11. Bruker BioSpin 2008-2009; File: Tutorial 11 - SPE-TT; Version: 2009-08-11; By: Dr."

Transcription

1 SPE-TT Tutorial Version

2 Introduction This document is a step-by-step guide for the usage of a SPE-TT system that elutes samples from SPE cartridges into the liquid handler. - Installation: Software & Hardware installation instructions (under construction). - Start-up: Start-up of an already installed instrument. - Transfer Process: Step-by-step description of a (series) of transfer. - Special Tasks: Insert Racks/ Supplied procedures and simple modifications of procedures/ Pooling of cartridges. - Trouble Shooting: Problems/Debug information. This is a Quick start guide! - Read the complete manual for details. - Installation & calibration of the Liquid Handler and Prospekt2 must be finished. This manual is based on - PrepGilsonST HyStar 3.2 (optionally SR1 or SR2) 2

3 Under Construction SPE-TT Installation

4 Software You must install PrepGilsonST and HyStar on the same computer. - Typically use the HyStar computer. When using the TopSpin computer note that you - must install PrepGilsonST and HyStar. - must have a sufficient number of COM ports. (1xLiquid Handler, 1xProspekt2, 2xLink = 4xCOM). If HyStar is already installed - do Help/About and check that is HyStar Version Do not install the Gilson215 Software from HyStar!!! - Open the windows control panel. Do add remove software. Select HyStar and do modify. Verify that the Gilson215 option is not selected. If HyStar is not installed - Install HyStar according to the general installation instructions. - Do not enable the Gilson215 option. - No special fraction collector license is required. 4

5 Data Connections Connection of the LiquidHandler through - Preferably build in COM1 of the computer. - Additional COM-ports supplied by a PCI board mounted in the computer - Optionally by USB-RS232 converter. - Not by Ethernet-RS232 converter (Moxa NPort Server) Other instruments can use any kind of COM ports. 5

6 SPE-TT Start-up

7 Prepare the Transfer in PrepGilsonST Open PrepGilsonST If the following window is shown, choose SPE-TT. If this windows is not shown - Check that the used configuration is SPE-TT. - See page 32 Change the configuration of how to select the SPE-TT application. If the liquid handler shows status yellow, do Service Tools/Initialize 7

8 Prepare the Transfer in PrepGilsonST For convenient access to instrument + racks press to move the arm. Connect the Prospekt2 to the T-piece at the needle. (Note: This connection might have been removed for other applications) Open the TubeBlock, and insert a sufficient number empty tubes. The solvent at the dilutor of the liquid handler should be the same as the solvent used for transfer in the Prospekt2. Note the position(s) of the racks with TubeBlock(s) and the empty tubes. In CleanProcedures do Purge system to remove air bubbles from dilutor and capillaries. 8

9 Check the Trays without Barcode reader With barcode reader racks are automatically detected. Stop Skip this page!!! Open the configuration with View Tray Check if the racks you want to use are available and correctly positioned. Move the mouse over the racks/trays to check for details (Note: lower part of the tooltip shows the properties of the selected zone i.e. where you clicked the last time with the mouse) Details of how to change he rack positions you find on page 23 Define Rack Positions manually. 9

10 Define Parameters for Transfer in HyStar In HyStar open the Transfer Settings from the menu(in flow injection) or the Prospekt2 context menu (in Acquisition). Set the cartridge drying time - 1min for dried cartridges - 30min for loaded cartridges. Set Probehead wash&dry to 2min & 150µl Define the volume in the NMR tube as excess volume. - 3mm 40mm 190µl - 2.5mm 40mm 140µl - 2mm 40mm 80µl - SJ 1.7mm 23mm 30µl - For precise transfer set flow µl/min. Activate the option finalize! 10

11 Special Version for HyStar <3.1 only Define Parameters for Transfer in HyStar With HyStar 3.2 and later skip this page! In HyStar enter FlowInjection. Open the TransferSettings. Set the cartridge drying time - 1min for dried cartridges - 30min for loaded cartridges. Set Probehead wash&dry to 2min & 150µl. Enter the complete volume (volume to the Needle tip + volume in the NMR tube) - For example volume to needle tip=180µl - Volume for 2mm Tube 40mm 80µl - TransferVolume = 260µl - For precise transfer set flow µl/min. Activate the option finalize! 11

12 SPE-TT Transfer Process

13 Preparation I Prepare Software Do Preparation and select Start Preparation Automation. The Create Orders dialog opens. Check for Created Orders - Typically it should be empty. - If there are orders left over from previous runs, check if you really want to execute them. If not mark and delete them. Check the displayed cartridge trays. - Verify that the right trays are displayed. If not use the Select tray buttons to load the correct trays files? 13

14 Preparation II Select Procedure/Cleaning Select the procedure for the transfer: - default_spett.gsp: Transfer only, no mixing. HyStar Versions <3.1 must use this procedure. - SPETT Mix 2_0mm Tubes.gsp SPETT Mix 2_5mm Tubes.gsp SPETT Mix 3_0mm Tubes.gsp: Mixing after transfer, liquid volume from HyStar must lead to 40mm filling height. - SPETT Mix 1_7mm 30ul.gsp: Mixing after transfer, liquid volume from HyStar must lead to 23mm filling height. For the first transfer an empty cartridge should be used for cleaning of the system. Identify a cartridge that can be used. - You can perform such a transfer in HyStar (If PrepGilsonST is not used, needle remains in the waste) or - Follow the instructions on the next pages for the automated transfer. Choose only this cartridge, select one tube and press create the order before you continue the selection with the real cartridges. 14

15 Transfer Select Cartridges Select * ) cartridge(s) with the mouse. - Selected cartridges are shown in the upper window. - For a simple assignment of cartridge to tube, select one cartridge and finish the setup as describe below. - Cartridges are processed in the order of their position in the tray. For a user defined order, finish the setup for the 1 st cartridge as described below. Click on destination to select the NMR tube(s). More cartridges can be selected in a second round. *)Select cartridges with left click. Multiple selections with CTRL-click or by opening a rectangle around a range of cartridges. 15

16 Transfer Select Tubes Select * ) a sufficient number of tubes as destination for the selected cartridges. The selected tubes are assigned to the cartridges and displayed in the upper window. The first selected tube is assigned to the first cartridge in the list. For each selected cartridge you must select a tube. *)Select cartridges with left click. Multiple selections with CTRL-click or by opening a rectangle around a range of cartridges. 16

17 Transfer Create Orders Press Create Orders The list of cartridges & tubes in the upper window is converted into orders in the right window. PrepGilsonST returns to the Source selection. Repeat the process until the you have defined all cartridges, then leave the window with OK. Attention OK will start the Automation. - No further cartridge can be added to the list, before current cartridges are completely processed. - Depending on the drying time this can be a lengthy process! 17

18 Transfer Verifying the Orders After closing the Create Order Files dialog the automation starts. Orders will be shown as white circles. First step is the test for valid parameters (volumes etc) which changes the color of the circles to purple. In case of problems the color turns to red and the automation stops. 1) The orders are normally sorted by the time of the Create Orders action. If more then one transfer was created at a time, the cartridges are sorted by their position in the tray. Check page 39 Potential problems Order of Transfer 18

19 Transfer Start the automation run After successful validation the liquid handler starts the automation. If HyStar is ready - A message appears. - The transfer starts. - No further actions are required. If HyStar is not ready, because the chromatography is still running - A message appears. - PrepGilsonST retries automatically every 60sec until HyStar is ready for transfer. - Ensure that HyStar automatically switches to the flow injection window after the chromatography. - When HyStar is in the flow injection window and ready for the transfer, the automation will continue normally. 19

20 Transfer Proceeding In the upper window of PrepGilsonST the progress can be observed: - Purple=Ready for transfer // Blue=Transfer running // Green=transfer done To remove filled tubes for NMR measurements - Do not remove tubes while the automation is running. The arm of the liquid handler can start moving at any time! - Do not press the Pause button. HyStar and PrepGilsonST may get out of synchronization. - Press the End after current order button, wait that the automation stops, remove the desired tubes, and restart the automation for the next schedules cartridges. 20

21 Results Do File/Open Print Dialog and Save New Preview. This will bring up a compact information of all orders For each order line you can get detailed information with the right mouse button. 21

22 SPE-TT Special Tasks

23 Define Rack Positions manually Open the configuration with View Configuration Click on the trays 23

24 New Rack I: Choose the position of the rack Check if the displayed racks corresponds to the current situation in the liquid handler If not - Delete any wrong positioned racks with a double click. - For racks that contain parts you must first delete the contained tube blocks/ well plate and then delete the rack. To insert the new racks - Click the right mouse button at the position where the rack is located. - Do Insert Barcode Simulation Data - Do not use Insert rack at selected site. With this procedure further definitions of rack properties are required. 24

25 New Rack II: Insert empty racks For MATCH tubes(all sizes) choose Rack Code 348B. For SampleJet tubes(all sizes) choose Rack Code 205MI. Enter an unique ID for the Rack, for example MatchRack1. All racks in the system should have different names. Leave the rest unchanged and press OK. Repeat the procedure for other racks. 25

26 Insert Tube Blocks in empty Rack I The previously inserted rack (348B or 205MI) with the two empty positions for the TubeBlocks is displayed in the tray. Click with the right mouse button the upper empty field and do Insert Barcode Simulation Data - Do not use Insert rack at selected site. With this procedure further definitions of rack properties are required. 26

27 Insert Tube Blocks in empty Rack II Possible tube blocks (MATCH or SampleJet) will be shown. - Select the block with correct tubing size. Define a unique ID, for example TubeBlock1_2mm. All blocks in the system must have different names. Leave all other settings unchanged. Repeat the procedure for the 2 nd block. 27

28 Supplied Procedures default_spett.gsp: All filling heights - Stays in drain during wash+dry of needle and dry of cartridge. - Goes to bottom 1 ) of selected source during transfer. - Returns to drain for next transfer. - No further actions. SPETT_Mix_2.0mm Tubes.gsp : Liquid level 40mm=80µl SPETT_Mix_2.5mm Tubes.gsp : Liquid level 40mm=140µl SPETT_Mix_3.0mm Tubes.gsp : Liquid level 40mm=190µl SPETT_Mix_1.7mm Tubes 30ul.gsp : Liquid level 23mm=30µl 1 ) - Stays in drain during wash+dry of needle and dry of cartridge. - Goes to bottom 1 ) of selected source during transfer. - Performs a mixing of the tube content after the transfer. - Returns to drain and cleans the needle, waits for the next transfer. - The mixing volume is fixed. Using smaller volumes in HyStar will cause the procedure to fail. Using higher sample volumes may result in inefficient mixing 1 ) After 10mm the system checks for obstructions. The procedure will work with 1.5mm needle and without needle switch, however the detection only works with 0.5mm needle + needle switch. 2 ) The 1.7mm procedure works with a lower filling height adapted to the 1.7mm (Cryo)Probe. 28

29 Test the Transfer Procedure PrepGilsonST supplies a possibility to check if a transfer is possible. With the selected procedure, the current volumes in HyStar and the type of NMR tubes you can test the orders. - Do Preparation and select Start Verify Test all Orders Testloop. - Follow the instructions following page 15 Transfer Select Cartridges identical to the normal setup procedure. - At the end PrepGilsonST will only verify the procedure but not start the transfer procedure. This allows you to check for errors. By running the standard Start Preparation Automation dialog - The above generated test orders can be deleted. - The above generated and tested orders can be started. 29

30 Pooling of Cartridges I Pooling means to combine the liquid from several cartridges into one sample tube. Proceed as follows - Use CTRL-Click to select the cartridges that contain the same compound for example cartridges A4,A8,A12. - As destination assign the same tube for all cartridges by using CTRL-Click on the same tube. - To avoid confusion, do Create orders before you define the next set of cartridges CTRL-Click 3x times on the same tube 30

31 Pooling of Cartridges II Take care, that the selected tubes/containers are large enough to hold the complete volume of all transfer procedures. The mixing procedures are not very efficient in this case. The calculation for the mixing assumes the amount of liquid from one transfer in a tube. 31

32 Change the configuration When opening PrepGilsonST a window is shown, where you can choose SPE-TT. If during start-up this windows is not shown: - do edit settings - reactivate the window - restart PrepGilsonST. 32

33 Start Transfer during Chromatography The SPE-TT system allows you to start PrepGilsonST while HyStar is still running a chromatography. In this case the transfer into the tubes automatically starts after the end of the chromatography. In HyStar - In Acquisition Shutdown Settings, activate Switch to Flow Injection window. - Define the transfer settings in the icon of the Prospekt2 before you start the automation in PrepGilsonST. - For details check the HyStar documentation. In PrepGilsonST - Start the automation while the chromatography runs. - Select the cartridges which you expect to be filled during the chromatography. - A message indicates that the transfer is not started. - The system will automatically retry every 60sec. Once HyStar is in the flow injection window, the transfer will start. 33

34 SPE-TT Trouble Shooting

35 Potential Problem Timing/Volumes in HyStar The correct setup of HyStar is essential. Excess volume - You must define the volume from cartridge to needle tip as transfer volume. - You must define the liquid in the tube as excess volume. - Otherwise the mixing procedure may not be correctly performed. Finalize - You must activate the finalize option - Otherwise the timing calculations for the movement of the needle is incorrect. The needle may go into the sample tube while drying gas is still going through the needle. For both settings the same amount of liquid is delivered, but. With this setting PrepGilsonST assumes 30µl in the tube and mixing will probably fail. 35

36 Potential Problem Rack/Block definition Note: Whenever a message like the following appears, you have tried to install a TubeBlock with same identifier two times. The ID must be a unique name! Change the name of the tube block/rack you want to insert. In this case for example TubeBlock2_2mm 36

37 Potential Problem Tray file selection If a error message like the following appears, you have chosen a tray file from a non-standard directory. Use tray files only from the standard HyStar-Directory C:\Program Files\Bruker Daltonik\HyStar\Hardware\Prospekt2 (or the HyStar on your system, that is shown in the message) 37

38 Potential Problem Volume too low Error during verification indicates wrong volumes. Right click for Error Info or Current Order Info for details. Example: Volume dispensed into the tube is too low for the mixing. Increase volume or use tube with smaller inner diameter. The minimum filling height for mixing is approx. 29mm (=2/3 of the standard volume) 38

39 Potential Problem Order of Transfer Inside each order cartridges are sorted by the position in the tray. The sorting of the orders is define with - This order is defined with Edit/Settings - Choose: By Time of the Creation or By Order Name = Tray position of the cartridges. Example: To use 1H12 as first cartridge for cleaning of the system. - Select 1H12, assign tube 1, press Create Order. Select 1A1, 1A2, 1A1, 1E3, 1B8, assign tube 2..6, press Create order. Leave the Create orders dialog. - The transfer is done in the order [1H12], [1A1, 1A2, 1B8, 1E3]. - If you select 1H12, 1A2, 1A1, 1E3, 1B8, assign tubes 1 6, press Create Order. Leave the Create orders dialog, the order is [1A1, 1A2, 1B8, 1E3, 1H12]. 39

40 Potential Problem Too much cleaning Each time you start a automation process a cleaning procedure is executed to clean the system but also to ensure that the complete flow path is filled with liquid. If you transfer cartridge individually and not as sequence, you can disable the cleaning to save time and deuterated solvent. Do disable the cleaning completely do Edit/Settings. - You can disable the Cleaning procedure at the beginning and/or end of the transfer. In this case you should perform a clean needle manually before the first cartridge transfer. 40

41 Potential Problem Needle does not fit The 0.5mm needle is supplied with a sensor, that detects if the needle inserts correctly into the tube/container. For this purpose the needle moves 20mm down and checks for any obstructions and then goes to the bottom of the tube. If the needle cannot move into the tube - The needle moves up and a second attempt is done. - If this also fails the automation is aborted. - As it is not possible to automatically abort the transfer in HyStar at this stage, the needle remains at the current position (on top of the tube). - By this you have a good chance to recover the sample from the cartridge. - All further cartridges are not transferred. 41

Interfacing PC ChargePayment Server with Focus

Interfacing PC ChargePayment Server with Focus Interfacing PC ChargePayment Server with Focus When you have decided to use the PC Charge Payment Server software with Focus, this feature will allow you to process credit cards through your credit card

More information

SA-9600 Surface Area Software Manual

SA-9600 Surface Area Software Manual SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The

More information

Installation and Operation Manual Portable Device Manager, Windows version

Installation and Operation Manual Portable Device Manager, Windows version Installation and Operation Manual version version About this document This document is intended as a guide for installation, maintenance and troubleshooting of Portable Device Manager (PDM) and is relevant

More information

1. Introduction... 3. 2.Fixture exterior view... 3. 3. Connecting the Robe Universal Interface... 4. 3.1 Software update of the fixture...

1. Introduction... 3. 2.Fixture exterior view... 3. 3. Connecting the Robe Universal Interface... 4. 3.1 Software update of the fixture... 1 Table of contests 1. Introduction... 3 2.Fixture exterior view... 3 3. Connecting the Robe Universal Interface... 4 3.1 Software update of the fixture... 4 3.2 Connecting a DMX console to the Media Fusion...

More information

1. Installing The Monitoring Software

1. Installing The Monitoring Software SD7000 Digital Microphone Monitor Software manual Table of Contents 1. Installing The Monitor Software 1.1 Setting Up Receivers For Monitoring 1.2 Running The Application 1.3 Shutdown 2. The Detail Monitoring

More information

DISTRICT SCHOOL BOARD OF COLLIER COUNTY. Internet Technology. Setting up VPN Access Windows 7. Revised 9-4-09

DISTRICT SCHOOL BOARD OF COLLIER COUNTY. Internet Technology. Setting up VPN Access Windows 7. Revised 9-4-09 DISTRICT SCHOOL BOARD OF COLLIER COUNTY Internet Technology Setting up VPN Access Windows 7 I N T E R N E T T E C H N O L O G Y Setting up VPN Access Windows 7 District School Board of Collier County Dr.

More information

TM Online Storage: StorageSync

TM Online Storage: StorageSync TM Online Storage: StorageSync 1 Part A: Backup Your Profile 1: How to download and install StorageSync? Where to download StorageSync? You may download StorageSync from your e-storage account. Please

More information

Accounting Manager. User Guide A31003-P1030-U114-2-7619

Accounting Manager. User Guide A31003-P1030-U114-2-7619 Accounting Manager User Guide A31003-P1030-U114-2-7619 Our Quality and Environmental Management Systems are implemented according to the requirements of the ISO9001 and ISO14001 standards and are certified

More information

QIAsymphony Management Console User Manual

QIAsymphony Management Console User Manual April 2012 QIAsymphony Management Console User Manual For use with software version 4.0 Sample & Assay Technologies Trademarks QIAGEN, QIAsymphony, Rotor-Gene (QIAGEN Group). InstallShield (Informer Technologies,

More information

Installation of the KX-P8420 Print Driver And Support Files (Windows). Introduction:

Installation of the KX-P8420 Print Driver And Support Files (Windows). Introduction: Installation of the KX-P8420 Print Driver And Support Files (Windows). Introduction: When installing the printer driver and support files for the KX-P8420 there are many options to consider. Choosing the

More information

WINDOWS 7/8 instruction guide for your Printrbot printer and computer software

WINDOWS 7/8 instruction guide for your Printrbot printer and computer software Software To start printing with your Printrbot Simple 3d printer, you need to download 3 pieces of software and two digital models (STL files). 1. The teensy Serial Driver. This connects the printer to

More information

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent

More information

Configuring, Customizing, and Troubleshooting Outlook Express

Configuring, Customizing, and Troubleshooting Outlook Express 3 Configuring, Customizing, and Troubleshooting Outlook Express............................................... Terms you ll need to understand: Outlook Express Newsgroups Address book Email Preview pane

More information

Table of Contents. 0. Internet Connectivity Assumptions..2. 0. Identifying the Network Wall Jack... 2. 0. Identifying the Ethernet Cable..

Table of Contents. 0. Internet Connectivity Assumptions..2. 0. Identifying the Network Wall Jack... 2. 0. Identifying the Ethernet Cable.. Table of Contents 0. Internet Connectivity Assumptions..2 0. Identifying the Network Wall Jack... 2 0. Identifying the Ethernet Cable..4 0. Identifying the Network Interface Card...5 0. Connecting Your

More information

Fingerprint Identity User Manual for the Griaule Biometric Framework 040-0103-01 Rev 1.00

Fingerprint Identity User Manual for the Griaule Biometric Framework 040-0103-01 Rev 1.00 Fingerprint Identity User Manual for the Griaule Biometric Framework 040-0103-01 Rev 1.00 www.griaulebiometrics.com Brazil Phone: 55-19-3289-2108 USA Phone: (408) 490 3438 Fingerprint Identity Index Getting

More information

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F Wireless Asset Monitoring - Local Food Safety Software BA/WAM-L-F Software Installation and User Guide System Overview The BAPI Wireless Asset Monitoring Local (WAM Local) Software receives temperature

More information

Printer Driver Installation Guide

Printer Driver Installation Guide Fujitsu Dot Matrix Printer DL Series Printer Driver Installation Guide - Windows 7 - Windows Server 2008 R2 Rev.01: April 12, 2010 IMPORTANT NOTE TO USERS For Windows 7 / Windows Server 2008 R2, install

More information

ROM ACCESS CONTROL USER S MANUAL

ROM ACCESS CONTROL USER S MANUAL ROM ACCESS CONTROL USER S MANUAL Manual Software Pro-Access Page: 1 PRO-ACCESS SOFTWARE GUIDE PRO-ACCESS SOFTWARE GUIDE 1 0. INTRODUCTION 3 1. INSTALLIG THE SOFTWARE 4 2. SOFTWARE OPERATORS AND COMPETENCIES.

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

Event Record Monitoring and Analysis Software. Software Rev. 3.0 and Up. User s Guide

Event Record Monitoring and Analysis Software. Software Rev. 3.0 and Up. User s Guide Event Record Monitoring and Analysis Software Software Rev. 3.0 and Up User s Guide 2 Contents Contents Chapter 1: About ERMAWin 4 Chapter 2: Overview 5 About this Manual 5 System Requirements 5 Installing

More information

Navios Quick Reference

Navios Quick Reference Navios Quick Reference Purpose: The purpose of this Quick Reference is to provide a simple step by step outline of the information needed to perform various tasks on the system. We begin with basic tasks

More information

Introduction. There are several bits of information that must be moved:

Introduction. There are several bits of information that must be moved: Backup and restore on new hardware XProtect Professional VMS Products 2014: XProtect Enterprise 2014, XProtect Professional 2014, XProtect Express 2014, XProtect Essential 2014 Introduction This document

More information

Hosting Users Guide 2011

Hosting Users Guide 2011 Hosting Users Guide 2011 eofficemgr technology support for small business Celebrating a decade of providing innovative cloud computing services to small business. Table of Contents Overview... 3 Configure

More information

Access Control Software Manual

Access Control Software Manual CONTENTS 1. Function overview...1 2. Installation environment...2 3. Concept description...3 4. Installation and Uninstallation...4 4.1 Installation...4 4.2 Uninstallation...10 5. Function instroduction...11

More information

Once form has been completed by one or more employees the information can be entered on the employees direct deposit screen.

Once form has been completed by one or more employees the information can be entered on the employees direct deposit screen. Banyon Data Systems, Inc. DIRECT DEPOSIT MODULE BDS Direct Deposit or ACH (Automated Clearing House) allows your entity to transfer its employee s pay directly to their bank accounts. This module does

More information

Bitrix Site Manager ASP.NET. Installation Guide

Bitrix Site Manager ASP.NET. Installation Guide Bitrix Site Manager ASP.NET Installation Guide Contents Introduction... 4 Chapter 1. Checking for IIS Installation... 5 Chapter 2. Using An Archive File to Install Bitrix Site Manager ASP.NET... 7 Preliminary

More information

Applied Biosystems 3730xl at DBS Step-by-Step Guide

Applied Biosystems 3730xl at DBS Step-by-Step Guide Applied Biosystems 3730xl at DBS Step-by-Step Guide A. Starting the 3730xl system 1. Turn on the computer and log on. Log on with user name Administrator. There is no password for this account. 2. Wait

More information

DiskPulse DISK CHANGE MONITOR

DiskPulse DISK CHANGE MONITOR DiskPulse DISK CHANGE MONITOR User Manual Version 7.9 Oct 2015 www.diskpulse.com info@flexense.com 1 1 DiskPulse Overview...3 2 DiskPulse Product Versions...5 3 Using Desktop Product Version...6 3.1 Product

More information

Addendum Advanced POS Printer Drivers

Addendum Advanced POS Printer Drivers Addendum Advanced POS Printer Drivers Overview With the introduction of version 4.0, The General Store now supports the use of advanced, manufacturer s printer drivers for certain point of sale printers.

More information

National Fire Incident Reporting System (NFIRS 5.0) NFIRS Data Entry/Validation Tool Users Guide

National Fire Incident Reporting System (NFIRS 5.0) NFIRS Data Entry/Validation Tool Users Guide National Fire Incident Reporting System (NFIRS 5.0) NFIRS Data Entry/Validation Tool Users Guide NFIRS 5.0 Software Version 5.3 Prepared for: Directorate of Preparedness and Response (FEMA) Prepared by:

More information

Altaro Hyper-V Backup - Getting Started

Altaro Hyper-V Backup - Getting Started Altaro Hyper-V Backup - Getting Started System Requirements Supported Host Operating Systems: Altaro Hyper-V Backup: o Windows 2008 R2 (all editions) o Windows 2008 R2 SP1 o Windows Hyper-V Server 2008

More information

Installing the Driver of your Plotter- / Engraver

Installing the Driver of your Plotter- / Engraver Installing the Driver of your Plotter- / Engraver By installing your plotter / engraver software the driver for your device will be pre-installed. When the device is switched on after the software setup,

More information

Brady IP Printer Installation Instructions

Brady IP Printer Installation Instructions Brady IP Printer Installation Instructions Ensure the following are available before commencing installation: The IP Printer and accessories (Printer, power cable, Product CD including Windows printer

More information

Network Server for Windows. Overview of the Sequencher Network Page 2. Installing Sequencher Server for the First Time Page 3

Network Server for Windows. Overview of the Sequencher Network Page 2. Installing Sequencher Server for the First Time Page 3 Network Server for Windows Installation Instructions Overview of the Sequencher Network Page 2 Installing Sequencher Server for the First Time Page 3 Adding Sequencher licenses to KeyServer Page 4 Updating

More information

Radian Mortgage Insurance

Radian Mortgage Insurance LOS Interface Administrator/User Guide Radian Mortgage Insurance 2012 PCLender an LPS Company Contents Introduction... 3 Interface Features... 3 Interface Requirements... 3 Interface Considerations...

More information

User s Guide DELUXE EDITION

User s Guide DELUXE EDITION User s Guide EZ-SCSI DELUXE EDITION Installing EZ-SCSI Deluxe in Windows 95 Installing EZ-SCSI Deluxe in Windows 95 1 Installing Windows 95 Drivers You can install EZ-SCSI Deluxe in Windows 95 in several

More information

PRACTICAL VIDEO SOLUTIONS. ipulse Manager Software. Installation Guide. Software Version 1.0

PRACTICAL VIDEO SOLUTIONS. ipulse Manager Software. Installation Guide. Software Version 1.0 PRACTICAL VIDEO SOLUTIONS ipulse Manager Software Installation Guide Software Version 1.0 2007 VideogeniX Corp. ipulse Software Installation Guide P/N: 040-00004-001 NOTICE TO USERS 2007 VideogeniX Corporation.

More information

Contents. 1.2 Software Installation... 1

Contents. 1.2 Software Installation... 1 Software Manual Contents 1 Software Installation... 1 1.1 Overview...1 1.2 Software Installation... 1 2 Introduction To Basic Function...5 2.1 Login System... 5 2.2 CMS Operating Interface...5 2.2.1 Operating

More information

LICENSE4J FLOATING LICENSE SERVER USER GUIDE

LICENSE4J FLOATING LICENSE SERVER USER GUIDE LICENSE4J FLOATING LICENSE SERVER USER GUIDE VERSION 4.5.5 LICENSE4J www.license4j.com Table of Contents Getting Started... 2 Floating License Usage... 2 Installation... 4 Windows Installation... 4 Linux

More information

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions TM SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS Quick Start Instructions Introduction WinLoad for Windows was developed to simplify and speed up the task of programming Paradox control panels. Remote

More information

File Management Utility. T u t o r i a l

File Management Utility. T u t o r i a l File Management Utility T u t o r i a l Contents System Requirements... 2 Preparing Files for Transfer to GlobalMark... 2 Application Launch... 2 Printer Setup... 2 Communication Status... 4 Communication

More information

USB Driver. Installation Manual

USB Driver. Installation Manual USB Driver Installation Manual Issue 1.00 Detailed guide for the installation of Actisense USB Drivers under the following operating systems: Windows XP / 2000 Windows Vista USB Driver Installation Manual

More information

ZKTime5.0 Attendance Management Software User Manual

ZKTime5.0 Attendance Management Software User Manual ZKTime5.0 Attendance Management Software User Manual Version: 1.4 Date: April. 2013 Software version: Build 149 About this Manual: This manual provides ZKTime5.0 software operation instruction, for example

More information

Volume AGKSOFT. Ruby VeriFone Back Office Software. Ruby VeriFone Guide

Volume AGKSOFT. Ruby VeriFone Back Office Software. Ruby VeriFone Guide Volume V AGKSOFT Ruby VeriFone Back Office Software Ruby VeriFone Guide Introduction T he Ruby VeriFone can be connected to your Windows PC using an RJ45 cable and a 9-pin connector included in your package.

More information

ChromQuest 5.0 Chromatography Data System

ChromQuest 5.0 Chromatography Data System ChromQuest 5.0 Chromatography Data System Administrator Guide CHROM-97251 Revision A March 2008 2008 Thermo Fisher Scientific Inc. All rights reserved. Surveyor is a registered trademark of Thermo Fisher

More information

Preparing Hyper-V Templates for Windows Server 2008 in HC

Preparing Hyper-V Templates for Windows Server 2008 in HC Preparing Hyper-V Templates for Windows Server 2008 in HC Table Of Contents Proprietary Notice... 5 Target Audience... 6 Document Conventions... 6 About Virtualization and Hyper-V... 7 HC Help... 8 Creating

More information

Design document Goal Technology Description

Design document Goal Technology Description Design document Goal OpenOrienteering Mapper is a program to draw orienteering maps. It helps both in the surveying and the following final drawing task. Support for course setting is not a priority because

More information

Communication with BushingGard using computer USB port

Communication with BushingGard using computer USB port Communication with BushingGard using computer USB port There are two ways of communication with BushingGard through computer USB port: Direct communication between computer USB port and BushingGard USB

More information

Software Application Tutorial

Software Application Tutorial Software Application Tutorial Copyright 2005, Software Application Training Unit, West Chester University. No Portion of this document may be reproduced without the written permission of the authors. For

More information

9 Working With DICOM. Configuring the DICOM Option

9 Working With DICOM. Configuring the DICOM Option 9 Working With DICOM DICOM (Digital Imaging and Communications in Medicine) is a format created by NEMA (National Electrical Manufacturers Association) to aid in the distribution and viewing of medical

More information

NEC Express5800 Series NEC ESMPRO AlertManager User's Guide

NEC Express5800 Series NEC ESMPRO AlertManager User's Guide NEC Express5800 Series NEC ESMPRO AlertManager User's Guide 7-2006 ONL-4152aN-COMMON-128-99-0606 PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs

More information

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version 1.0. 2014 PROMISE Technology, Inc. All Rights Reserved.

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version 1.0. 2014 PROMISE Technology, Inc. All Rights Reserved. Vess A2000 Series NVR Storage Appliance Windows Recovery Instructions Version 1.0 2014 PROMISE Technology, Inc. All Rights Reserved. Contents Introduction 1 Different ways to backup the system disk 2 Before

More information

900612 ESP -- SURF Center : ESP GUI Users Guide

900612 ESP -- SURF Center : ESP GUI Users Guide 900612 ESP -- SURF Center : ESP GUI Users Guide This page last changed on Oct 31, 2011 by kgomes. This is a quick sequence of steps to get the user up and running with the ESP GUI application. When you

More information

1. Check the Accessories

1. Check the Accessories This Quick User Guide helps you get started with the IRIScan Book Executive 3 scanner. This scanner is supplied with the software applications Readiris Pro 14 (Windows and Mac ), IRIScan Direct and IRISCompressor

More information

Legal Notes. Regarding Trademarks. Model supported by the KX printer driver. 2010 KYOCERA MITA Corporation

Legal Notes. Regarding Trademarks. Model supported by the KX printer driver. 2010 KYOCERA MITA Corporation Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change for improvement without notice. We cannot be held liable for any problems

More information

SyncThru Database Migration

SyncThru Database Migration SyncThru Database Migration Overview Database Migration for SyncThru application is an intuitive tool that enables the data stored in the database of an older version of SyncThru, to be moved to the database

More information

Download Software 2.33 For Vigil civil I, II, 2 + & Military II, II+, II+c -

Download Software 2.33 For Vigil civil I, II, 2 + & Military II, II+, II+c - Download Software 2.33 For Vigil civil I, II, 2 + & Military II, II+, II+c - User s Manual User s Manual Vigil Download Software Page 1 of 27 V2015.11 The Vigil is endorsed by: User s Manual Vigil Download

More information

Amicus Link Guide: PCLaw

Amicus Link Guide: PCLaw Amicus Link Guide: PCLaw Applies to: Amicus Attorney Premium 2015 Synchronize your Amicus and PCLaw matters and clients, and dynamically exchange your Amicus time entries and expenses to PCLaw. About the

More information

To successfully initialize Microsoft Outlook (Outlook) the first time, email settings need to be verified.

To successfully initialize Microsoft Outlook (Outlook) the first time, email settings need to be verified. TO: UAN CLIENTS FROM: UAN STAFF DATE: OCTOBER 8, 2008 SUBJECT: Steps for Initial Setup of Microsoft Outlook To successfully initialize Microsoft Outlook (Outlook) the first time, email settings need to

More information

User Manual Web DataLink for Sage Line 50. Version 1.0.1

User Manual Web DataLink for Sage Line 50. Version 1.0.1 User Manual Web DataLink for Sage Line 50 Version 1.0.1 Table of Contents About this manual...3 Customer support...3 Purpose of the software...3 Installation...6 Settings and Configuration...7 Sage Details...7

More information

Call Recorder Oygo Manual. Version 1.001.11

Call Recorder Oygo Manual. Version 1.001.11 Call Recorder Oygo Manual Version 1.001.11 Contents 1 Introduction...4 2 Getting started...5 2.1 Hardware installation...5 2.2 Software installation...6 2.2.1 Software configuration... 7 3 Options menu...8

More information

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001) LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide Rev. 03 (November, 2001) Copyright Statement Trademarks Copyright 1997 No part of this publication may be reproduced in any form or by any

More information

Orange Apps UserLogonUSB V1.0

Orange Apps UserLogonUSB V1.0 Orange Apps UserLogonUSB V1.0 KUKA KRC4 User Documentation As of 07/08/2013 Document version: 1.0 2 Introduction Copyright 2013 OrangeApps GmbH Arnikaweg 1 87471 Durach Germany www.orangeapps.de This documentation

More information

ibidi PumpControl Instruction Manual Version 1.5.2

ibidi PumpControl Instruction Manual Version 1.5.2 ibidi PumpControl Instruction Manual Version 1.5.2 ibidi PumpControl instructions II ibidi GmbH 2016, Version 1.5.2, 04 May 2016 Table of contents 1. General Information... 3 1.1 System Requirements...3

More information

First Time On-Campus Remote Desktop Connection ipad Edition

First Time On-Campus Remote Desktop Connection ipad Edition First Time On-Campus Remote Desktop Connection ipad Edition General: This guide is a step-by-step guide for configuring and using an ipad to remotely connect to a work computer from on campus. This guide

More information

2. Manage the power of the target device

2. Manage the power of the target device Please have "MagicConnect user account list" that we sent you upon delivery time be ready at your hand Here, we take OS: Windows 7 Ultimate, Display method: category as a sample for describing this Quick

More information

OPTAC Fleet Viewer. Instruction Manual

OPTAC Fleet Viewer. Instruction Manual OPTAC Fleet Viewer Instruction Manual Stoneridge Limited Claverhouse Industrial Park Dundee DD4 9UB Help-line Telephone Number: 0870 887 9256 E-Mail: optac@stoneridge.com Document version 4.0 Part Number:

More information

AIM SOFTWARE AND USB DRIVER INSTALLATION PROCEDURE

AIM SOFTWARE AND USB DRIVER INSTALLATION PROCEDURE AIM SOFTWARE AND USB DRIVER INSTALLATION PROCEDURE CONTENTS AIM software and USB Driver installation Chapter 1 Installing AIM software and AIM USB driver... 2 Chapter 2 Installation under Microsoft Windows

More information

Software Tutorial. Biomek 4000. Laboratory Automation Workstation. PN A99502AA October 2012. Beckman Coulter, Inc. 250 S. Kraemer Blvd.

Software Tutorial. Biomek 4000. Laboratory Automation Workstation. PN A99502AA October 2012. Beckman Coulter, Inc. 250 S. Kraemer Blvd. Software Tutorial Biomek 4000 Laboratory Automation Workstation October 2012 Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA 92821 Biomek 4000 Software Tutorial (October 2012) Copyright 2012 Beckman

More information

USER AND INSTALLATION MANUAL

USER AND INSTALLATION MANUAL Revision 1 - October 2013 User and installation manual O-link The manufacturer OWANDY reserves the right to make modifications to its products or to their specifications in order to improve the performance,

More information

How to operate the BD FACSCanto flow cytometer

How to operate the BD FACSCanto flow cytometer How to operate the BD FACSCanto flow cytometer Preface Dear colleague, the BD FACSCanto flow cytometer is use to operate, however, it is a delicate instrument for measuring fluorescence of single cells.

More information

WebSphere Business Monitor V6.2 Business space dashboards

WebSphere Business Monitor V6.2 Business space dashboards Copyright IBM Corporation 2009 All rights reserved IBM WEBSPHERE BUSINESS MONITOR 6.2 LAB EXERCISE WebSphere Business Monitor V6.2 What this exercise is about... 2 Lab requirements... 2 What you should

More information

CONFIGURATION MANUAL File Transfer Daemon. Version 3.6 - July 2013

CONFIGURATION MANUAL File Transfer Daemon. Version 3.6 - July 2013 CONFIGURATION MANUAL File Transfer Daemon Version 3.6 - July 2013 IP2Archive - Configuration Manual - File Transfer Daemon Version 3.6 Copyright EVS Broadcast Equipment S.A. Copyright 2003-2013. All rights

More information

Central Management Software CV3-M1024

Central Management Software CV3-M1024 Table of Contents Chapter 1. User Interface Overview...5 Chapter 2. Installation...6 2.1 Beginning Installation...6 2.2 Starting the CMS software...10 2.3 Starting it from the Start menu...10 2.4 Starting

More information

WhatsUp Gold v16.1 Installation and Configuration Guide

WhatsUp Gold v16.1 Installation and Configuration Guide WhatsUp Gold v16.1 Installation and Configuration Guide Contents Installing and Configuring Ipswitch WhatsUp Gold v16.1 using WhatsUp Setup Installing WhatsUp Gold using WhatsUp Setup... 1 Security guidelines

More information

Installation and Demonstration Manual

Installation and Demonstration Manual Installation and Demonstration Manual This manual presents the procedures for installing the program and running the demonstration programs of MakeTracks from the Main Menu Selection Getting Started Copyright

More information

Merchant On The Move Android Professional Edition User Guide and Tutorial

Merchant On The Move Android Professional Edition User Guide and Tutorial Merchant On The Move Android Professional Edition User Guide and Tutorial Copyright (c) 2010 Primary Merchant Solutions Inc All rights reserved Merchant On The Move for Android p. 1 Requirements Merchant

More information

EaseUS Todo Backup user guide. EaseUS Todo Backup. Central Management Console. User guide - 1 -

EaseUS Todo Backup user guide. EaseUS Todo Backup. Central Management Console. User guide - 1 - EaseUS Todo Backup Central Management Console User guide - 1 - Table of Contents Welcome... - 3 - Overview... - 3 - How to use this manual... - 3 - Getting started... - 4 - Hardware requirements... - 4

More information

How to connect your Victron to a computer with VE Bus Quick Configure

How to connect your Victron to a computer with VE Bus Quick Configure How to connect your Victron to a computer with VE Bus Quick Configure Before connecting your Victron to a computer the following is important: - Only identical models with VE Bus software (see sticker

More information

Electronic Filing System Setting Up Your Adobe Acrobat Digital ID November 2012

Electronic Filing System Setting Up Your Adobe Acrobat Digital ID November 2012 Electronic Filing System Setting Up Your Adobe Acrobat Digital ID November 2012 To apply your electronic signature to electronic forms, you must first set up a Digital ID in Adobe Acrobat using the digital

More information

MET 306 Activity 6. Using Pro/MFG Milling Operations Creo 2.0. Machining a Mast Step

MET 306 Activity 6. Using Pro/MFG Milling Operations Creo 2.0. Machining a Mast Step Using Pro/MFG Milling Operations Creo 2.0 Machining a Mast Step If the Trim option is grayed out when trimming the mill volume, Save (making sure the.asm file is going to the correct subdirectory), Exit

More information

ACR Triad Site Server Click Once Software System

ACR Triad Site Server Click Once Software System ACR Triad Site Server Click Once Software System Version 2.5 20 October 2008 User s Guide American College of Radiology 2007 All rights reserved. CONTENTS INTRODUCTION...3 ABOUT TRIAD...3 DEFINITIONS...4

More information

Changing Your Cameleon Server IP

Changing Your Cameleon Server IP 1.1 Overview Technical Note Cameleon requires that you have a static IP address defined for the server PC the Cameleon server application runs on. Even if the server PC has a static IP address, you may

More information

PRINT CONFIGURATION. 1. Printer Configuration

PRINT CONFIGURATION. 1. Printer Configuration PRINT CONFIGURATION Red Flag Server5 has improved the designs of the printer configuration tool to facilitate you to conduct print configuration and print tasks management in a more convenient and familiar

More information

Xythos on Demand Quick Start Guide For Xythos Drive

Xythos on Demand Quick Start Guide For Xythos Drive Xythos on Demand Quick Start Guide For Xythos Drive What is Xythos on Demand? Xythos on Demand is not your ordinary online storage or file sharing web site. Instead, it is an enterprise-class document

More information

Abila Grant Management. Document Management

Abila Grant Management. Document Management Abila Grant Management This is a publication of Abila, Inc. Version 2014 2014 Abila, Inc. and its affiliated entities. All rights reserved. Abila, the Abila logos, and the Abila product and service names

More information

Lenovo Online Data Backup User Guide Version 1.8.14

Lenovo Online Data Backup User Guide Version 1.8.14 Lenovo Online Data Backup User Guide Version 1.8.14 Contents Chapter 1: Installing Lenovo Online Data Backup...5 Downloading the Lenovo Online Data Backup Client...5 Installing the Lenovo Online Data

More information

Software Operations Manual

Software Operations Manual Software Operations Manual Version 5.0 BinMaster 7201 North 98th Street Lincoln, NE 68507 Phone: 402-434-9102 / Fax: 402-434-9133 info@binmaster.com - www.binmaster.com System Requirements PC with 1GHz

More information

Where do I find? Global Outlook options and features

Where do I find? Global Outlook options and features Where do I find? Changed Outlook version and can now no longer find your favorite feature? Feel like test driving Outlook 2010? Or have you heard of a feature but don't know where to find it in Outlook?

More information

File Manager User Guide

File Manager User Guide File Manager User Guide Please note: EasySiteOptimizer Version 1.6 is supplied with Web Hosting (IBP) and Advanced Web Hosting only. File Manager Introduction to File Manager To access File Manager, select

More information

GREEN HOUSE DATA. E-Mail Services Guide. Built right. Just for you. greenhousedata.com. Green House Data 340 Progress Circle Cheyenne, WY 82007

GREEN HOUSE DATA. E-Mail Services Guide. Built right. Just for you. greenhousedata.com. Green House Data 340 Progress Circle Cheyenne, WY 82007 GREEN HOUSE DATA Built right. Just for you. E-Mail Services Guide greenhousedata.com 1 Green House Data 340 Progress Circle Cheyenne, WY 82007 Table of Contents Getting Started on Business Class Email

More information

TX3 Series TELEPHONE ACCESS SYSTEMS. Configurator Quick Start. Version 2.2 Mircom Copyright 2014 LT-973

TX3 Series TELEPHONE ACCESS SYSTEMS. Configurator Quick Start. Version 2.2 Mircom Copyright 2014 LT-973 TX3 Series TELEPHONE ACCESS SYSTEMS Configurator Quick Start Version 2.2 Mircom Copyright 2014 LT-973 Copyright 2014 Mircom Inc. All rights reserved. Mircom Configurator Software Guide v.2.2 for Windows

More information

Windows 95 Revision B Installation Instructions

Windows 95 Revision B Installation Instructions Windows 95 Revision B Installation Instructions Follow the instructions in this document if you are installing Live200 1.5 on a PC that runs Windows 95 revision B (OSR2). The Windows 95 version number

More information

Scan to PC Desktop: Image Retriever 5.2 for Xerox WorkCentre C2424

Scan to PC Desktop: Image Retriever 5.2 for Xerox WorkCentre C2424 Scan to PC Desktop: Image Retriever 5.2 for Xerox WorkCentre C2424 Scan to PC Desktop includes Image Retriever, which is designed to monitor a specified folder on a networked file server or local drive

More information

Introduction. - Please be sure to read and understand Precautions and Introductions in CX-Simulator Operation Manual and

Introduction. - Please be sure to read and understand Precautions and Introductions in CX-Simulator Operation Manual and Introduction - Please be sure to read and understand Precautions and Introductions in CX-Simulator Operation Manual and CX-Programmer Operation Manual before using the product. - This guide describes the

More information

McAfee SMC Installation Guide 5.7. Security Management Center

McAfee SMC Installation Guide 5.7. Security Management Center McAfee SMC Installation Guide 5.7 Security Management Center Legal Information The use of the products described in these materials is subject to the then current end-user license agreement, which can

More information

owncloud Configuration and Usage Guide

owncloud Configuration and Usage Guide owncloud Configuration and Usage Guide This guide will assist you with configuring and using YSUʼs Cloud Data storage solution (owncloud). The setup instructions will include how to navigate the web interface,

More information

USER GUIDE MANTRA WEB EXTRACTOR. www.altiliagroup.com

USER GUIDE MANTRA WEB EXTRACTOR. www.altiliagroup.com USER GUIDE MANTRA WEB EXTRACTOR www.altiliagroup.com Page 1 of 57 MANTRA WEB EXTRACTOR USER GUIDE TABLE OF CONTENTS CONVENTIONS... 2 CHAPTER 2 BASICS... 6 CHAPTER 3 - WORKSPACE... 7 Menu bar 7 Toolbar

More information

Proteome Discoverer Version 1.4

Proteome Discoverer Version 1.4 Xcalibur Proteome Discoverer Version 1.4 Installation Guide XCALI-97507 Revision A December 2012 2012 Thermo Fisher Scientific Inc. All rights reserved. Xcalibur is a registered trademark of Thermo Fisher

More information

User Manual Printer driver PRO 300 / ECO 200 / Express Plus / Pegasus State: April 2003 3073.01.991.90.08

User Manual Printer driver PRO 300 / ECO 200 / Express Plus / Pegasus State: April 2003 3073.01.991.90.08 User Manual Printer driver PRO 300 / ECO 200 / Express Plus / Pegasus State: April 2003 3073.01.991.90.08 Installation instructions driver PRO300 / ECO200 / Express / Plus / Pegasus 3 Contents 1. Introduction

More information