IBM eserver pseries. September, Revised April IBM Corporation. server. pseries
|
|
- Silas Reynolds
- 8 years ago
- Views:
Transcription
1 server H C R server U6 pseries Revised April 2003 September, 2005
2 Ubicación del p615 en el cosmos de servidores
3 Servidores de IBM zseries The most reliable, mission-critical systems on earth pseries Most powerful, technologically advanced UNIX servers iseries High-performance integrated business servers for mid-market companies xseries Intel-based servers with mainframe-inspired reliability technologies
4 El mercado de servidores UNIX Quarterly UNIX-based Revenue Share 45% 45% 40% 35% 40% 30% 35% 25% 20% 30% 15% 25% 10% 5% 20% 15% 10% 5% Q102 Q202 WW UNIX Server Revenue Share Rolling 4Q Average Q302 Q402 Q103 Q203 Q303 Q403 Q104 Q204 Q304 Q404 Q105 Q205 IBM HP Sun Other Source: IDC Quarterly Server Tracker, 8/05
5 POWER4+: El motor del p615
6 pseries 615 POWER4+ Chip Technology Superescalar. Habilidad para ejecutar hasta 8 instrucciones en paralelo. Superpipelined. Posibilidad de completar cinco instrucciones por ciclo. L1 instruction cache 128K/chip;64K/processor. L1 data cache 64K/chip; 32K/processor. L2 cache 1440K/chip; shared between processors). POWER4+ microprocessor D I L3 Cache >1GHz CPU L3 Controller L3 Directory Memory >1GHz CPU Shared L2 Cache Fabric Controller Distributed Switch Processor local bus I/O Bus D I
7 pseries 615 POWER4+ Chip Technology Each processor contains two FXUs (fixed point units) two FPUs (floating point units) two load/store units a branching unit a CR (condition register) unit
8 POWER Microprocessor Roadmap POWER microns 1.0 to 1.3 GHz Core Shared L2 Distributed Switch 2001 Distributed Switch Shared L2 LPAR Autonomic computing Chip multiprocessing GHz Core POWER microns 1.2 to 1.9 GHz Core Shared L2 Distributed Switch 1.2 to 1.9 GHz Core Larger L2 More LPARs High-speed Switch 0.13 microns POWER5 >> GHz Core Shared L2 Distributed Switch microns >>> GHz Core GHz Core Shared L2 Distributed Switch >>> GHz Core way SMP Sub-processor partitioning Enhanced Distributed Switch Enhanced core parallelism Improved floating-point performance Faster memory environment Dynamic firmware updates
9 POWER : The Most Scaleable Architecture POWER5 POWER2 PPC 603e PPC 401 POWER3 PPC 750 PPC 405GP POWER4 POWER4+ PPC 750CXe PPC 750FX PPC 440GP PPC 750GX PPC 970FX PPC 440GX Servers Desktop Games Embedded Binary Compatibility
10 Anatomía del p615
11 Internal Structure of p615 Rack Model Six hot-plug PCI-X slots: Three long 64-bit 133 MHz 3.3v One short 64-bit 133 MHz 3.3v Two short 32-bit 66 MHz 3.3v Service processor Hot-plug power supplies (one redundant optional) 3 hot-plug fans (redundancy) server H C R U6 pseries Server planar board contains: Two 4-packs (separate backplanes) hot-swappable Ultra320 SCSI disks 1st four-pack standard Three media bays Op-panel Two slimline One standard RJ-48 connector (when in use, pre-empts the S1 serial port on rear) One or two GHz or 2-way 1.45 GHz POWER4+ processors, 1.5MB L2 Cache, 8MB L3 Cache, 1 to 16GB DDR Chipkill memory, Three serial ports, two optional HMC ports, keyboard, mouse and parallel ports 10/100 and 10/100/1000 (1 Gbps) Ethernet ports
12 H C R U6 pseries IBM eserver pseries Rear View of p615 Rack Model server server Two hot-plug AC power supplies with dual isolated line cords Parallel Three serial ports (S1, S2, S3) Mfg. Diagnostic port (not for client use) S2 S3 Rack indicator light port S1 HMC 1 HMC 2 10/100 Ethernet 10/100/1000 Ethernet Six hot-plug PCI-X slots: Three long 64-bit 133 MHz 3.3v One short 64-bit 133 MHz 3.3v Two short 32-bit 66 MHz 3.3v
13 p615 Memory Quad Positioning Main memory ranges from 1GB to 16GB ECC DDR SDRAM. Memory is configured in two quads on the planar board, and is pre-balanced by design for optimal performance with each quad split between two synchronous memory interface (SMI) controllers. Plan ahead to reach desired maximum memory to avoid discarding memory. 1GB quad = 4 X 256MB DIMMs 2GB quad = 4 X 512MB DIMMs 4GB quad = 4 X 1GB DIMMs 8GB quad = 4 X 2GB DIMMs SMI L3 Shared L2 Quad 1 Quad 2 SMI Distributed switch
14 pseries 615 Server Peak Bandwidth per 1.2 GHz 2-way Chip 12.8GB/sec (= 2 x 16 1/3 Clock Speed) For 2-way chip Shared L2 L3 6.4GB/sec (= four 8-byte 200 MHz) M E M O R Y 1 to 16GB Distributed switch GX Bus 3.2GB/sec (= dual 4-byte 1/3 Clock Speed) Six PCI-X slots I/O Hub 2GB/sec
15 pseries 615 Server Peak Bandwidth per 1.45 GHz 2-way Chip 15.5GB/sec For 2-way chip Shared L2 L3 6.4GB/sec M E M O R Y 1 to 16GB Distributed switch GX Bus 3.9GB/sec Six PCI-X slots I/O Hub 2GB/sec
16 RAS (Fiabilidad, Disponibilidad y Servicialidad)
17 IBM pseries H C R U6 pseries server server H C R U6 pseries 24x7 IBM eserver pseries POWER4+ Reliability Across the Product Line pseries server Mainframe-inspired RAS Reliability, Availability and Serviceability Self- Protecting Self- Configuring Self- Optimizing Self- Healing server First Failure Data Capture DDR ECC Chipkill memory Bit-steering/redundant memory Memory soft scrubbing Redundant power, fans Dynamic Processor Deallocation Deallocate PCI-X bus, L2/L3 cache Persistent memory deallocation Hot-plug PCI-X slots, fans, power Internal LED diagnostics Hot-swappable disk drives
18 First Failure Data Capture Technology CPU L1 Cache L2/L3 Cache Error Checkers Fault Isolation Register (FIR) (unique fingerprint of each error captured) Service Processor Old Failure Recreate Strategy Run diagnostic test cases during service call Repair based on test case symptom Questionable correlation to original problem Development focus on improved test cases Open service action plan if failure not recreated Test cases used to try to isolate failures and verify correct operation Disk Memory Log Error Nonvolatile RAM Reliably identify each failing component, reducing costly downtime First Failure Data Capture: an IBM Exclusive Specialized hardware designed to capture failure data at time of failure Repair based on root-cause analysis Direct correlation to original client problem Engineering focus on built-in error detection and capture Service action plan driven by captured failure information Test cases used to only to verify correct operation
19 Start Off With Quality-based Design Fault Avoidance Designing extra quality into system to keep errors from ever happening Mainframe-class components and technologies - Reduced power consumption, cooler operating temperatures for increased reliability
20 ECC Memory Integrity and Availability Memory scrubbing for soft single-bit errors that are corrected in the background while memory is idle, to help prevent multiple-bit errors. Failing memory bit steered to spare memory chip Chipkill X X... Dynamically reassign memory I/O via bit-steering if error threshold is reached on same bit Spare memory chip Scatter memory chip bits across four separate ECC words for Chipkill recovery Bit-scattering allows normal single bit ECC error processing, thereby keeping system running with a Chipkill failure. Bit-steering allows memory lines from a spare memory chip to be dynamically reassigned to a memory module with a faulty line to keep system running. If all bits are used up on the spare memory chips, and threshold is reached, the Service Processor will be invoked to request deferred maintenance at a time acceptable to client.
21 Built-in Redundancies for Non-stop Operation N+1 Redundancy Use of redundancy to remain operational with full resources Redundant spare memory chips Redundant fans - Fans will speed up to try to compensate for failed fan Redundant power supplies (optional)
22 p615 PCI Bus and Card Error Recoveries PCI-X Controller X Problem with damaged connection results in PCI-X bus error - That particular slot is varied offline by system - All other slots remain active - System stays operational without the slot active - If PCI card is damaged, replace with new one - If slot is damaged, plan for maintenance at client s convenience
23 Replacement of Parts While System Runs Concurrent Maintenance Online hot-plug of defective electromechanical components keeps system operational Disk drives Cooling fans Power subsystems PCI, PCI-X adapter cards
24 Quicker Service for Client Convenience Service Productivity Increasing service productivity means more client uptime Internal LED diagnostics identify components that require service LEDs on I/O provide status of PCI-X slots and disk drives for power, hot-swap and need for service
25 Sistemas Operativos
26 server H C R U6 server pseries pseries server IBM eserver pseries AIX 5L & Linux AIX Linux Servers AIX Hypervisor Linux Native 64-bit Linux High performance POWER4 SMP, LPAR, Clusters Proven, reliable pseries Surprisingly affordable compared to Intel SMPs Standard Linux APIs in AIX Common Functionality Interoperability Testing AIX Toolbox for Linux Apps - Linux development environment on AIX Run Linux and AIX on the same pseries server Workload Consolidation - Linux for Infrastructure, AIX for Database Server Consolidation - Develop, Test, Production Competitive Consolidation
27 Referencias
28 For more details, see the POWER4 System Microarchitecture white paper at 1.ibm.com/servers/eserver/pseries/h ardware/whitepapers/power4.html (or search for "power4 architecture" in the Search window at
29 Y ya está... (a no ser que tengais más preguntas)
Setting a new standard
Changing the UNIX landscape IBM pseries 690 nearly doubling the power of the pseries 680, previously the most powerful pseries server available. 2 The powerful IBM ^ pseries 690 Highlights Datacenter-class
More informationbusinesses must respond instantaneously, delivering information and solutions tailored for individuals.
No compromise entry server for an on demand world IBM ^ pseries 615 pseries Model 6C3 Highlights High-end reliability, availability and serviceability features at an attractive entry price Autonomic capabilities
More informationIBM Europe Announcement ZG08-0232, dated March 11, 2008
IBM Europe Announcement ZG08-0232, dated March 11, 2008 IBM System x3450 servers feature fast Intel Xeon 2.80 GHz/1600 MHz, 3.0 GHz/1600 MHz, both with 12 MB L2, and 3.4 GHz/1600 MHz, with 6 MB L2 processors,
More informationTipos de Máquinas. 1. Overview - 7946 x3550 M2. Features X550M2
Tipos de Máquinas X550M2 1. Overview - 7946 x3550 M2 IBM System x3550 M2 Machine Type 7946 is a follow on to the IBM System x3550 M/T 7978. The x3550 M2 is a self-contained, high performance, rack-optimized,
More informationIBM pseries 610: Models 6C1 and 6E1
Affordable, versatile, powerful entry servers IBM pseries 610: Models 6C1 and 6E1 services, insurance, healthcare and other environments that support remote stores, branches, regional offices and kiosks.
More informationPower Redundancy. I/O Connectivity Blade Compatibility KVM Support
1.Blade server Blade Chasis Specification Blade Chassis Form Factor 6U-10U rack mountable Chasis to House at least 6 or more Blade Servers Chasis Should be configured with 6 blades Network Redundancy I/O
More informationIBM Power Systems Facts and Features POWER7 Blades and Servers October 2010
IBM Power Systems Facts and Features POWER7 Blades and Servers October 2010 IBM Power Systems servers and IBM BladeCenter blade servers using IBM POWER6 and POWER6+ processors are described in a separate
More informationQuickSpecs. HP Integrity cx2620 Server. Overview
Overview At A Glance Product Numbers HP cx2620 Server with one 1.6GHz/3MB single-core CPU AB401A HP cx2620 Server with one 1.4GHz/12MB dual-core AB402A Standard System Features Multiple Operating Environment
More informationCisco MCS 7845-I2 Unified Communications Manager Appliance
Cisco MCS 7845-I2 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
More informationHighly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I
Highly Scalable Server for Many Possible Uses MAXDATA PLATINUM Server 3200 I MAXDATA PLATINUM Server 3200 I: Highly Scalable Server for Many Possible Uses Standard Features Now more than ever, profitable
More informationIBM Power 720 Express server
IBM Power 720 Express server Reliable, secure, and flexible 4U rack or tower server ideal for midsized business solutions Highlights Reliable, secure distributed application server or consolidation server
More informationHewlett-Packard Superdome Servers
Jane Wright Product Report 19 August 2003 Hewlett-Packard Superdome Servers Summary HP Superdome servers are available with HP s own PA-RISC processors or Itanium 2 processors. The high-end Itanium 2-based
More informationAnnex 1: Hardware and Software Details
Annex : Hardware and Software Details Hardware Equipment: The figure below highlights in more details the relation and connectivity between the Portal different environments. The number adjacent to each
More informationPCI, PCI-X, PCI-X DDR,
Redbooks Paper PCI, PCI-X, PCI-X DDR, and PCIe Placement Rules for IBM System i Models This IBM Redpaper publication describes the configuration and card placement rules for servers and adapters that you
More informationApplication Server V240 Platform
Application Server V240 Platform The V240 Application Server (V240) features four hot-swappable disks with redundant power supplies for reliable system performance. The server also has three PCI slots
More informationMaximizing Server Storage Performance with PCI Express and Serial Attached SCSI. Article for InfoStor November 2003 Paul Griffith Adaptec, Inc.
Filename: SAS - PCI Express Bandwidth - Infostor v5.doc Maximizing Server Storage Performance with PCI Express and Serial Attached SCSI Article for InfoStor November 2003 Paul Griffith Adaptec, Inc. Server
More informationSAN TECHNICAL - DETAILS/ SPECIFICATIONS
SAN TECHNICAL - DETAILS/ SPECIFICATIONS Technical Details / Specifications for 25 -TB Usable capacity SAN Solution Item 1) SAN STORAGE HARDWARE : One No. S.N. Features Description Technical Compliance
More informationCopyright 2013, Oracle and/or its affiliates. All rights reserved.
1 Oracle SPARC Server for Enterprise Computing Dr. Heiner Bauch Senior Account Architect 19. April 2013 2 The following is intended to outline our general product direction. It is intended for information
More informationChapter 5 Cubix XP4 Blade Server
Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel
More informationCisco MCS 7825-H3 Unified Communications Manager Appliance
Cisco MCS 7825-H3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
More informationIBM TotalStorage Network Attached Storage 100
1U low-profile IBM NAS solution for central management of remote and distributed locations IBM TotalStorage Network Attached Storage 100 Model R12 Ease of use and ease of management Web-browser interface
More informationTerms of Reference Microsoft Exchange and Domain Controller/ AD implementation
Terms of Reference Microsoft Exchange and Domain Controller/ AD implementation Overview Maldivian Red Crescent will implement it s first Microsoft Exchange server and replace it s current Domain Controller
More informationTotalStorage Network Attached Storage 300G Cost effective integration of NAS and LAN solutions
TotalStorage Network Attached Storage 300G Cost effective integration of NAS and LAN solutions Overview The new IBM TotalStorage Network Attached Storage 300G series is part of the overall IBM Storage
More informationProduct Brief. R7A-200 Processor Card. Rev 1.0
Product Brief R7A-200 Processor Card Rev 1.0 Order Codes for Default Configuration: 900-015-601 900-017-601 R7A-200 Broadcom XLR732 atca Processor/Switch Board with dual 1.0Ghz CPU's, 8GB DDR2 per XLR,
More informationRedpaper. IBM System x3950 M2 and x3850 M2 Technical Introduction. Table of Contents. David Watts Robert Moon
Redpaper David Watts Robert Moon IBM System x3950 M2 and x3850 M2 Technical Introduction Table of Contents Summary of changes....................................................... 2 Overview................................................................
More informationSUN SPARC ENTERPRISE M4000 SERVER
SUN SPARC ENTERPRISE M4000 SERVER KEY FEATURES MAINFRAME-CLASS RAS AND UNMATCHED INVESTMENT PROTECTION Optimized for 24x7 mission critical computing and large shared memory applications Mainframe class
More informationHIGH AVAILABILITY IN THE DATACENTER
HIGH AVAILABILITY IN THE DATACENTER SUN SPARC ENTERPRISE M4000, M5000, M8000, AND M9000 SERVERS White Paper July 2008 Sun Microsystems, Inc. Table of Contents Higher Availability for Lower Total Cost of
More informationArrow ECS sp. z o.o. Oracle Partner Academy training environment with Oracle Virtualization. Oracle Partner HUB
Oracle Partner Academy training environment with Oracle Virtualization Technology Oracle Partner HUB Overview Description of technology The idea of creating new training centre was to attain light and
More informationQuickSpecs. HP Smart Array 5312 Controller. Overview
Overview Models 238633-B21 238633-291 (Japan) Feature List: High Performance PCI-X Architecture High Capacity Two Ultra 3 SCSI channels support up to 28 drives Modular battery-backed cache design 128 MB
More informationCisco MCS 7816-I3 Unified Communications Manager Appliance
Cisco MCS 7816-I3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
More informationIBM TotalStorage Network Attached Storage 300G
High-performance storage access solution IBM TotalStorage Network Attached Storage 300G IBM Network Attached Storage 300G (dual-engine configuration) Highlights Optimized performance Fault tolerant Dual
More informationVTrak 15200 SATA RAID Storage System
Page 1 15-Drive Supports over 5 TB of reliable, low-cost, high performance storage 15200 Product Highlights First to deliver a full HW iscsi solution with SATA drives - Lower CPU utilization - Higher data
More informationCisco MCS 7825-H2 Unified CallManager Appliance
Cisco MCS 7825-H2 Unified CallManager Appliance This product is no longer being sold and might not be supported. Read the End-of-Life Notice to learn about potential replacement products and information
More informationCisco 7816-I5 Media Convergence Server
Cisco 7816-I5 Media Convergence Server Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks, enabling easy collaboration every time from
More informationAn Oracle Technical White Paper September 2013. SPARC M6-32 Server Architecture
An Oracle Technical White Paper September 2013 SPARC M6-32 Server Architecture Introduction... 2 Overview of SPARC M6-32 Server Capabilities... 3 SPARC M6-32 Server Components... 4 System Architecture...
More informationIBM System x family brochure
IBM Systems and Technology System x IBM System x family brochure IBM System x rack and tower servers 2 IBM System x family brochure IBM System x servers Highlights IBM System x and BladeCenter servers
More informationPowerLinux introduction
PowerLinux introduction Course materials may not be reproduced in whole or in part without the prior written permission of IBM. 9.0 Unit objectives After completing this unit, you should be able to: Recognize
More informationIBM ^ xseries ServeRAID Technology
IBM ^ xseries ServeRAID Technology Reliability through RAID technology Executive Summary: t long ago, business-critical computing on industry-standard platforms was unheard of. Proprietary systems were
More informationH ARDWARE C ONSIDERATIONS
H ARDWARE C ONSIDERATIONS for Sidewinder 5 firewall software Compaq ProLiant ML370 G2 This document provides information on specific system hardware required for running Sidewinder firewall software on
More informationModels Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers
Overview The SA6400A is a high-performance Ultra320, PCI-X array controller. It provides maximum performance, flexibility, and reliable data protection for HP OpenVMS AlphaServers through its unique modular
More informationA+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware
A+ Guide to Managing and Maintaining Your PC, 7e Chapter 1 Introducing Hardware Objectives Learn that a computer requires both hardware and software to work Learn about the many different hardware components
More informationSystem x3650 Type 7979
System x3650 Type 7979 User s Guide Table 1. Features and specifications Microprocessor: v Intel Xeon FC-LGA 771 dual-core with 4 MB Level-2 cache or quad-core with 8 MB (2x4 MB) Level-2 cache v Support
More informationAs enterprise data requirements continue
Storage Introducing the Dell PERC 6 Family of SAS RAID ControlLers By Bhanu Prakash Dixit Sanjay Tiwari Kedar Vaze Joe H. Trickey III The Dell PowerEdge Expandable RAID Controller (PERC) 6 family of enterprise-class
More informationAchieving a High Performance OLTP Database using SQL Server and Dell PowerEdge R720 with Internal PCIe SSD Storage
Achieving a High Performance OLTP Database using SQL Server and Dell PowerEdge R720 with This Dell Technical White Paper discusses the OLTP performance benefit achieved on a SQL Server database using a
More informationSmall Industries Development Bank of India Request for Proposal (RfP) For Purchase of Intel Servers for Various Locations
Small Industries Development Bank of India Request for Proposal (RfP) For Purchase of Intel Servers for Various Locations Tender : 400/2011/702/BYO/ISD dated February 25, 2011 PRE-BID CLARIFICATIONS Placed
More informationA Quantum Leap in Enterprise Computing
A Quantum Leap in Enterprise Computing Unprecedented Reliability and Scalability in a Multi-Processor Server Product Brief Intel Xeon Processor 7500 Series Whether you ve got data-demanding applications,
More informationIBM TotalStorage Network Attached Storage 200 Models 201/226
Scalable storage for heterogeneous LAN environments IBM TotalStorage Network Attached Storage 200 Models 201/226 IBM Network Attached Storage 200 (rack model) Highlights Dedicated Fully-integrated, Flexible
More informationChapter 6. Inside the System Unit. What You Will Learn... Computers Are Your Future. What You Will Learn... Describing Hardware Performance
What You Will Learn... Computers Are Your Future Chapter 6 Understand how computers represent data Understand the measurements used to describe data transfer rates and data storage capacity List the components
More informationVirtualization what it is?
IBM EMEA Virtualization what it is? Tomaž Vincek System p FTSS CEMAAS tomaz.vincek@si.ibm.com 2007 IBM Corporation What is needed? A very strong requirement: reduce costs and optimize investments On a
More informationHow To Run A Power5 On A Powerbook On A Mini Computer (Power5) On A Microsoft Powerbook (Power4) On An Ipa (Power3) On Your Computer Or Ipa On A Minium (Power2
Planning for Virtualization Jaqui Lynch Userblue Jaqui.lynch@mainline.com http://www.circle4.com/papers/ubvirtual.pdf Agenda Partitioning Concepts Virtualization Planning Hints and Tips References 1 Partitioning
More informationDeploying a 48,000-user Exchange Server 2010 Environment with Hitachi Compute Blade 2000 and Hitachi Adaptable Modular Storage 2500
1 Deploying a 48,000-user Exchange Server 2010 Environment with Hitachi Compute Blade 2000 and Hitachi Adaptable Modular Storage 2500 Reference Architecture Guide Leo Nguyen April 2011 Month Year Feedback
More informationMainframe. Large Computing Systems. Supercomputer Systems. Mainframe
1 Large Computing Systems Server Farm Networked cluster of interchangeable file/application servers Provides load balancing for availability and reliability Blade Server Server farm in a single cabinet
More informationPerformance Comparison of Fujitsu PRIMERGY and PRIMEPOWER Servers
WHITE PAPER FUJITSU PRIMERGY AND PRIMEPOWER SERVERS Performance Comparison of Fujitsu PRIMERGY and PRIMEPOWER Servers CHALLENGE Replace a Fujitsu PRIMEPOWER 2500 partition with a lower cost solution that
More informationIBM System Storage DS5020 Express
IBM DS5020 Express Manage growth, complexity, and risk with scalable, high-performance storage Highlights Mixed host interfaces support (Fibre Channel/iSCSI) enables SAN tiering Balanced performance well-suited
More informationSUN FIRE X4170, X4270, AND X4275 SERVER ARCHITECTURE Optimizing Performance, Density, and Expandability to Maximize Datacenter Value
SUN FIRE X4170, X4270, AND X4275 SERVER ARCHITECTURE Optimizing Performance, Density, and Expandability to Maximize Datacenter Value White Paper April 2009 Abstract In compact 1U and 2U form factors, the
More informationOracle Database Reliability, Performance and scalability on Intel Xeon platforms Mitch Shults, Intel Corporation October 2011
Oracle Database Reliability, Performance and scalability on Intel platforms Mitch Shults, Intel Corporation October 2011 1 Intel Processor E7-8800/4800/2800 Product Families Up to 10 s and 20 Threads 30MB
More informationNEC Corporation of America Intro to High Availability / Fault Tolerant Solutions
NEC Corporation of America Intro to High Availability / Fault Tolerant Solutions 1 NEC Corporation Technology solutions leader for 100+ years Established 1899, headquartered in Tokyo First Japanese joint
More informationGrid on Blades. Basil Smith 7/2/2005. 2003 IBM Corporation
Grid on Blades Basil Smith 7/2/2005 2003 IBM Corporation What is the problem? Inefficient utilization of resources (MIPS, Memory, Storage, Bandwidth) Fundamentally resources are being wasted due to wide
More informationNetwork Attached Storage 300
Network Attached Storage 300 High performance, dual-engine NAS solution Overview The IBM Network Attached Storage 300 was designed to meet your storage requirements across many demanding environments.
More informationHP 9000 rp3410-2 and rp3440-4 Servers
HP 9000 rp3410-2 and rp3440-4 Servers Data sheet From entry-class 2-processor systems up to the high-end, 128-way HP 9000 Superdome, the HP 9000 server family delivers world-class, highperformance computing
More informationpræsentation oktober 2011
Johnny Olesen System X presale præsentation oktober 2011 2010 IBM Corporation 2 Hvem er jeg Dagens agenda Server overview System Director 3 4 Portfolio-wide Innovation with IBM System x and BladeCenter
More informationEvaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation
Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation Evaluation report prepared under contract with HP Executive Summary The computing industry is experiencing an increasing demand for
More informationSPARC T5-1B SERVER MODULE
SPARC T5-1B SERVER MODULE KEY FEATURES 16 cores per processor deliver a remarkable 2.3x the system throughput over the previous generation 1.2x single-thread performance increase and double the L3 cache
More informationSUN FIRE X4150, X4250, AND X4450 SERVER ARCHITECTURE. Breakthrough Density Using Sun and Intel Technology
SUN FIRE X4150, X4250, AND X4450 SERVER ARCHITECTURE Breakthrough Density Using Sun and Intel Technology White Paper September 2008 Table of Contents Executive Summary................................................
More informationSUN FIRE X4170 SERVER
SUN FIRE X4170 SERVER KEY FEATURES AND BENEFITS ULTIMATE IN ENTERPRISE PERFORMANCE FOR DATABASE MANAGEMENT OR WEB APPLICATIONS FEATURES Your business is under increasing pressure to deliver more services
More informationServers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor
Servers, Clients Displaying max. 60 cameras at the same time Recording max. 80 cameras Desktop or rackmount form factor IVR-40/40-DSKT Intellio standard server PC 60 60 Recording 60 cameras Video gateway
More informationOpenPower: IBM s Strategy for Best of Breed 64-bit Linux
HRG Harvard Research Group HRG Assessment: OpenPower: IBM s Strategy for Best of Breed 64-bit Linux Overview As users migrate from RISC/UNIX platforms to Linux, to which 64-bit architecture will they move
More informationSystemverwaltung 2009 AIX / LPAR
Systemverwaltung 2009 AIX / LPAR Course materials may not be reproduced in whole or in part without the prior written permission of IBM. 4.0.1 Integrated Virtualization Manager (IVM) (1 of 2) Provides
More informationSeradex White Paper. Focus on these points for optimizing the performance of a Seradex ERP SQL database:
Seradex White Paper A Discussion of Issues in the Manufacturing OrderStream Microsoft SQL Server High Performance for Your Business Executive Summary Microsoft SQL Server is the leading database product
More informationItanium 2 Platform and Technologies. Alexander Grudinski Business Solution Specialist Intel Corporation
Itanium 2 Platform and Technologies Alexander Grudinski Business Solution Specialist Intel Corporation Intel s s Itanium platform Top 500 lists: Intel leads with 84 Itanium 2-based systems Continued growth
More informationWhat s the best disk storage for my i5/os workload?
What s the best disk storage for my i5/os workload? Sue Baker IBM System i Advanced Technical Support Agenda Storage management styles Storage technologies for i5/os Considerations for implementing and
More informationMinimum Hardware Specifications Upgrades
Minimum Hardware Specifications Upgrades http://www.varian.com/hardwarespecs ARIA for Medical Oncology, & ARIA for Radiation Oncology Version 13.0 1 ARIA Version 13.0 Minimum Hardware Specifications Minimum:
More informationSun SPARC Enterprise M5000 Server Specifications Processor
SUN SPARC ENTERPRISE M5000 SERVER KEY FEATURES MAINFRAME-CLASS RAS AND UNMATCHED INVESTMENT PROTECTION Optimized for 24x7 mission critical computing and large shared memory applications Mainframe class
More informationChapter 4 System Unit Components. Discovering Computers 2012. Your Interactive Guide to the Digital World
Chapter 4 System Unit Components Discovering Computers 2012 Your Interactive Guide to the Digital World Objectives Overview Differentiate among various styles of system units on desktop computers, notebook
More informationThe Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment
The Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment Introduction... 2 Virtualization addresses key challenges facing IT today... 2 Introducing Virtuozzo... 2 A virtualized environment
More informationThe team that wrote this redbook Comments welcome Introduction p. 1 Three phases p. 1 Netfinity Performance Lab p. 2 IBM Center for Microsoft
Foreword p. xv Preface p. xvii The team that wrote this redbook p. xviii Comments welcome p. xx Introduction p. 1 Three phases p. 1 Netfinity Performance Lab p. 2 IBM Center for Microsoft Technologies
More informationIBM System x family brochure
IBM Systems and Technology System x IBM System x family brochure IBM System x rack, BladeCenter and tower servers 2 IBM System x family brochure Highlights IBM System x and BladeCenter servers help deliver
More informationHigh Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis
High Performance 2U Storage Server Based on the Intel Socket R E5-2600 processor platform, the ASUS RS720-E7/RS12 server offers customers an extensive feature set: mass storage. high memory capacity, outstanding
More informationINDIAN INSTITUTE OF TECHNOLOGY KANPUR Department of Mechanical Engineering
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Department of Mechanical Engineering Enquiry No: Enq/IITK/ME/JB/02 Enquiry Date: 14/12/15 Last Date of Submission: 21/12/15 Formal quotations are invited for HPC cluster.
More informationXserve Transition Guide. November 2010
Transition Guide November 2010 2 Introduction Key points Apple will not be developing a future version of Orders for will be accepted through January 31, 2011 Apple will honor all warranties and extended
More informationOracle Server X5-2. Product Overview
Oracle Server X5-2 Oracle Server X5-2 is designed from the ground up to be the best two-socket server for running Oracle Database in a clustered configuration and also for high-density virtualization environments
More informationHow To Write An Article On An Hp Appsystem For Spera Hana
Technical white paper HP AppSystem for SAP HANA Distributed architecture with 3PAR StoreServ 7400 storage Table of contents Executive summary... 2 Introduction... 2 Appliance components... 3 3PAR StoreServ
More informationCertification: HP ATA Servers & Storage
HP ExpertONE Competency Model Certification: HP ATA Servers & Storage Overview Achieving an HP certification provides relevant skills that can lead to a fulfilling career in Information Technology. HP
More informationHP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler
Overview HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler Models Smart Array 5i Plus Controller and BBWC Enabler bundled Option Kit (for ProLiant DL380 G2, ProLiant DL380
More informationThe safer, easier way to help you pass any IT exams. Industry Standard Architecture and Technology. Title : Version : Demo 1 / 5
Exam : HP2-T16 Title : Industry Standard Architecture and Technology Version : Demo 1 / 5 1.How does single-mode fiber compare with multimode fiber? A. Single mode fiber has a higher bandwidth and lower
More informationSPARC M5-32 SERVER. Product Overview
SPARC M5-32 SERVER KEY FEATURES Massive system scalability and performance with up to 32 SPARC M5 processors and 32 TB of system memory 6-core, 8 threads per core, SPARC M5 processor with extra large 48
More informationOC By Arsene Fansi T. POLIMI 2008 1
IBM POWER 6 MICROPROCESSOR OC By Arsene Fansi T. POLIMI 2008 1 WHAT S IBM POWER 6 MICROPOCESSOR The IBM POWER6 microprocessor powers the new IBM i-series* and p-series* systems. It s based on IBM POWER5
More informationAzul Compute Appliances
W H I T E P A P E R Azul Compute Appliances Ultra-high Capacity Building Blocks for Scalable Compute Pools WP_ACA0209 2009 Azul Systems, Inc. W H I T E P A P E R : A z u l C o m p u t e A p p l i a n c
More informationPositioning the Roadmap for POWER5 iseries and pseries
Positioning the Roadmap for POWER5 iseries and pseries Guy Paradise Larry Amy Ian Jarman Agenda The Case For Common Platforms Diverse Markets: the pseries and iseries Common Platform: the Roadmap for pseries
More informationLogical Operations. Control Unit. Contents. Arithmetic Operations. Objectives. The Central Processing Unit: Arithmetic / Logic Unit.
Objectives The Central Processing Unit: What Goes on Inside the Computer Chapter 4 Identify the components of the central processing unit and how they work together and interact with memory Describe how
More informationIBM Total Storage Virtual Tape Server Storage Solution Provides Exceptional Function, Scalability, Attachment, Availability, and Performance
Exam : 000-670 Title : IBM Total Storage Virtual Tape Server Storage Solution Provides Exceptional Function, Scalability, Attachment, Availability, and Performance Version : DEMO 1 / 10 1.A customer named
More informationSUN ORACLE EXADATA STORAGE SERVER
SUN ORACLE EXADATA STORAGE SERVER KEY FEATURES AND BENEFITS FEATURES 12 x 3.5 inch SAS or SATA disks 384 GB of Exadata Smart Flash Cache 2 Intel 2.53 Ghz quad-core processors 24 GB memory Dual InfiniBand
More informationData Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade
Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Universal dual socket server blade with high computing and I/O performance in a small form factor The PRIMERGY BX Blade Servers are the ideal
More informationSun Microsystems Special Promotions for Education and Research January 9, 2007
Sun Microsystems Special Promotions for Education and Research Solve big problems on a small budget with Sun-Education s trusted partner for cutting-edge technology solutions. Sun solutions help your campus
More informationOpenSPARC T1 Processor
OpenSPARC T1 Processor The OpenSPARC T1 processor is the first chip multiprocessor that fully implements the Sun Throughput Computing Initiative. Each of the eight SPARC processor cores has full hardware
More informationEmulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide
Emulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide The Emulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter enables high-performance connection
More informationSPARC M6-32 SERVER. Product Overview
SPARC M6-32 SERVER KEY FEATURES AND BENEFITS Extreme performance levels with up to 32 TB of system memory to host entire applications and databases in memory Performance for any size workload twice as
More informationCisco UCS C220 M3 Server
Data Sheet Cisco UCS C220 M3 Rack Server Product Overview The Cisco Unified Computing System (Cisco UCS) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking and storage
More informationHUAWEI Tecal E6000 Blade Server
HUAWEI Tecal E6000 Blade Server Professional Trusted Future-oriented HUAWEI TECHNOLOGIES CO., LTD. The HUAWEI Tecal E6000 is a new-generation server platform that guarantees comprehensive and powerful
More information