Tegneforklaring... Side 126. Digitalt termometer... Side 127. Digital termostat, Prime-serien... Side 128. Melketank controller...
|
|
- Charlotte Fox
- 8 years ago
- Views:
Transcription
1 Dixell produkter GRUPPE Tegnefklaring... Side 126 Digitalt termometer... Side 127 Digital termostat, Prime-serien... Side 128 Melketank controller... Side 133 Multifunksjons controller type XR Side 134 Multifunksjons controller type Wing XW... Side 138 Kabinett controller type XM Side 146 HACCP controller type XR XW... Side 149 Quick chill and hold controller type XB... Side 154 Temperatur og fuktighets controller type XH... Side 155 Trinn kobler type XC Side 156 Compress racks controller type XC Side 157 Hastighetsregulat type XV... Side 158 Digital termostat type XT... Side 5 Fuktighets controller type XH... Side 170 Digital trykk controller type XP... Side 172 Monit og kontrollenhet type XJ Side 175 Følere PTC / NTC / PT-100 / TC / TRYKK... Side 178 Tilbehør... Side 181 Alle priser er i Nske kroner eks MVA, og er MVA-pliktige. Vi følger Nske Kuldegrossisters Fenings salgs og leveringsbetingelser. Vi tar fbehold om ste valutaendringer og trykkfeil. Oslo, 1. juni 2003 Ullstrøm Fepo AS Kr. Augustsgt Oslo Tlf: Fax:
2 GRUPPE Tegnefklaring 126 Ullstrøm-Fepo AS Kr. Augustsgt Oslo Tlf: Fax:
3 Digitalt Termometer GRUPPE Model Description Power Supply LCD DIGITAL THERMOMETERS - 28 x 48 range C LC11 white included, 3m cable, 3 digits with d. p. Battery LR44 213,- LC11 Battery LR44 213,- included, 1.5m cable, 3 digits with d. p. black DIGITAL THERMOMETERS - with maximum/minimum temperature log - 31x E range: 2digit: -50/+99 C 3 digit: - 50,0 99,9 þ C XT 11 S 2 digits XT 11 S 3 digits 1,5m. PVC cable INCLUDED (range: C) Optional display update times (1 3 min) 1,5m. PVC cable INCLUDED (range: C) Optional display update times (1 3 min) 381,- 400,- 407,- 400,- 422,- 443,- 450,- 443,- DIGITAL THERMOMETERS x74 - range C 3 digits with D. P. XR 100 C How to der X T 1 1 S - A B C 0 0 A B C Power Supply Digits n / Measurement unit Display update delay 0 = 1 = 24Vac/dc 4 = 110Vac 5 = 230Vac 0 = 2 digits C 1 = 2 digits F 2 = 3 digits C 3 = 3 digits F 0 = No delay 1 = 1 min 2 = 3 min X R C - A B 0 D 0 A B D Power Supply Inputs Measurement unit 0 = 1 = 24Vac/dc 4 = 110Vac 5 = 230Vac 0 = PTC N = NTC C = C F = F 554,- 630,- 621,- 621,- Ullstrøm Fepo AS Kr. Augustsgt Oslo Tlf: Fax:
4 GRUPPE Digital Termostat - 31x64 mm Model Inputs Relay outputs Alarms Power Supply DIGITAL THERMOSTATS with maximum/minimum temperature log x 64 - XR 10 S 8A 687,- DIGITAL THERMOSTATS, with OFF cycle defrost x 64 - XR 20 S 8A 694,- Name Available f models Meaning Surcharge OPTIONS Buzzer XR10S XR20S 1 = Buzzer 46,- How to der X R 0 S - 0 B C D 0 B C D Inputs Buzzer Measurement P = PTC N = NTC 1 Only f XR10S 0 = Buzzer not present 1 = Buzzer present unit C = C F = F H 1 = C Heating L 1 = F Heating 128 Ullstrøm-Fepo AS Kr. Augustsgt Oslo Tlf: Fax:
5 Prime Series Prime Serien - 32x74 mm Model Inputs Relay outputs Alarms Digital Input Power Supply GRUPPE DIGITAL THERMOSTATS with maximum/minimum temperature log x 74 - XR 10 C 600,- 8A 675,- 667,- 667,- XR 10 C 20A 614,- 689,- 682,- 682,- DIGITAL THERMOSTATS, with OFF cycle defrost x 74 - XR 20 C 8A XR 20 C XR 30 C XR 30 C 20A 8A 20A Only f 12V 24V Only f 12V 24V 600,- 675,- 667,- 667,- 614,- 689,- 682,- 682,- 689,- 766,- 758,- 758,- 704,- 780,- 772,- 772,- MULTIFUNCTION CONTROLLERS x 74 - XR 40 C 8A Only f 12V 24V XR 40 C 20A Only f 12V 24V 689,- 766,- 758,- 758,- 704,- 780,- 772,- 772,- MULTIFUNCTION CONTROLLERS x 74-3 digits with D. P. Operating range: NTC probes: C XR 60 C 8A XR 70 C 8A 776,- 852,- 843,- 843,- N.A. N.A. Ullstrøm Fepo AS Kr. Augustsgt Oslo Tlf: Fax:
6 GRUPPE Prime Serien - 32x74 mm Name Available f models Meaning Surcharge OPTIONS Digital Input/ buzzer Disconnectable terminal blocks XR20C XR10C XR20) XR40C( 24 Vac/dc) XR30C ( 24 Vac/dc) XR60C XR20C = Digital Input = Buzzer = Buzzer = Digital Input+Buzzer 46,- 46,- 46,- 91,- Available f models with 8A relays = Yes 61,- Prime Series How to der X R C - A B C D E A B C D E Power Supply Inputs Digital Input / Buzzer Measurement unit 0 = P = PTC 2 0 =No / Buzzer not present C = C 1 = 24Vac/dc N = NTC 1 = Yes / Buzzer not present F = F 4 = 110Vac 2 =No / Buzzer present H 1 = C Heating 5 = 230Vac 3 = Yes / Buzzer present L 1 = F Heating Compress output 0 = 8(3)A / Standard terminal blocks 1 = 20(8)A / Standard terminal blocks 2 2 = 8(3)A / Disconnectable terminal blocks 1 Only f XR10C 2 Only f XR10C, XR20C, XR30C, XR40C 130 Ullstrøm-Fepo AS Kr. Augustsgt Oslo Tlf: Fax:
7 Prime Serien - DIN rail GRUPPE Prime Series Model Inputs Relay outputs Alarms Digital Input Power Supply DIGITAL THERMOSTATS with maximum/minimum temperature log - - DIN RAIL - XR 10 D 8A 24Vac XR 10 D 20A 24Vac 928,- 928,- 928,- 947,- 947,- 947,- DIGITAL THERMOSTATS, with OFF cycle defrost - - DIN RAIL - XR 20 D 8A 24Vac XR 20 D 20A 24Vac XR 30 D 8A 24Vac XR 30 D 20A 24Vac 928,- 928,- 928,- 947,- 947,- 947, , , , , , ,- MULTIFUNCTION CONTROLLERS - - DIN RAIL - XR 40 D 24Vac 8A XR 40 D 24Vac 20A 1 046, , , , , ,- MULTIFUNCTION CONTROLLERS - - DIN RAIL - 3 digits with D. P. Operating range: NTC probes: C XR 60 D 8A 24Vac XR 60 D 20A 24Vac XR 70 D 8A 24Vac XR 70 D 20A 24Vac 1 141, , , , , , , , , , , ,- Ullstrøm Fepo AS Kr. Augustsgt Oslo Tlf: Fax:
8 GRUPPE Prime Serien - DIN rail Name Available f models Meaning Surcharge OPTIONS Buzzer XR10D XR20D XR30D XR40D XR60D XR70D = Buzzer 46,- Prime Series How to der X R D - A B C D E A B C D E Power Supply Inputs Buzzer Measurement unit 2 = 24Vac P* = PTC 0 = Buzzer not present C = C 4 = 110Vac N = NTC 1 = Buzzer present F = F 5 = 230Vac H 1 = C Heating L 1 = F Heating * Only f XR10D, X20D XR30D, X40D 1 Only f XR10D Compress output 0 = 8(3)A 1 = 20(8)A 132 Ullstrøm-Fepo AS Kr. Augustsgt Oslo Tlf: Fax:
9 Melketank controller GRUPPE Model Inputs Relay outputs Alarms Power Supply MULTIFUNCTION MILK TANK CONTROLLERS x 74 - XR 80 C XR 80 C 8A 20A 844,- 913,- 913,- 858,- 927,- 927,- MULTIFUNCTION MILK TANK CONTROLLERS - - DIN RAIL - XR 80 D 8A 24Vac XR 80 D 20A 24Vac 1 182, , , , , ,- Name Available f models Meaning Surcharge OPTIONS Buzzer XR80C () XR80D (24Vac, 110Vac, 230Vac) = Buzzer 46,- How to der X R 80 - A B C D E A B C D E Power Supply Inputs Buzzer Measurement unit Compress output 0 = 2 = 24Vac 4 = 110Vac 5 = 230Vac P = PTC N = NTC 0 = Buzzer not present 1* = Buzzer present C = C F = F 0 = 8(3)A 1 = 20(8)A * Not available f XR80C at 110Vac o 230Vac Ullstrøm Fepo AS Kr. Augustsgt Oslo Tlf: Fax:
10 GRUPPE Multifunksjons controller XR100 XR500 SERIES XR100 with built RS485 serial output ModBUS Model Regulation Inputs Relay outputs Alarms Digital Inputs Power Supply DIGITAL THERMOSTATS x 74 - XR 110 C 8A XR 110 C 20A 821,- 898,- 908,- 908,- 837,- 913,- MULTIFUNCTION CONTROLLERS x 74 - Opt. XR 120 C 8A XR 120 C 20A XR 130 C 821,- 898,- 908,- 908,- 837,- 913, , ,- XR 140 C 1 018, ,- XR 150 C 1 112, ,- XR 0 C 1 112, ,- XR 170 C 1 180, ,- XR 172 C A from XR40SL 909,- 134 Ullstrøm-Fepo AS Kr. Augustsgt Oslo Tlf: Fax:
11 XR100 XR500 GRUPPE Model Regulation Inputs Relay outputs Alarms Digital Inputs Power Supply MULTIFUNCTION CONTROLLERS - - DIN RAIL - XR 120 D 8A 1 140, ,- XR 120 D 20A XR 130 D A 1 156, , , ,- XR 140 D 1 232, ,- XR 0 D 1 277, ,- XR 170 D A 1 315, ,- MULTIFUNCTION CONTROLLERS x 74 - Opt. XR 530 C 1 259, ,- XR 570 C 1 422, ,- XR 572 C from XR40SL XR30SL 1 153,- MULTIFUNCTION CONTROLLERS - - DIN RAIL - XR 530 D A 1 437, ,- XR 563 D A 1 551, ,- XR 570 D A 1 559, ,- Ullstrøm Fepo AS Kr. Augustsgt Oslo Tlf: Fax:
12 GRUPPE XR100 XR500 Model Available f models Relay outputs Alarms Built-in RS485 Power Supply POWER MODULES (SLAVE) AND CABLES - DIN RAIL - XR30SL XR172C, XR572C A 8A 24Vac 560, /230Vac 560,- XR30SL XR172C, XR572C 30A A 24Vac 595, ,- 595,- XR40SL XR172C, XR572C A 8A 24Vac 642, /230Vac 642,- XR40SL XR172C, XR572C 30A A 24Vac 653, ,- 653,- CAB/OS1 Multipolar connect f XR SLAVE 1m 50,- CAB/OS2 Multipolar connect f XR SLAVE 2m 76,- HOT KEY FOR PARAMETERS PROGRAMMING HOT KEY XR110C - XR120C - XR130C - XR140C - XR150C - XR0C from Controller 76,- XR170C - XR172C - XR530C - XR570C - XR572C - XR120D XR130D - XR140D - XR0D - XR170D - XR530D - XR563D XR570D REMOTE DISPLAY - 31 x 64-3 digits with D. P. XW REP XR130C - XR140C - XR150C - XR0C XR170C - XR172C - from Controller 439,- XR530C - XR570C - XR572C CAB/REP1 Multipolar connect f XW REP 1m 46,- CAB/REP3 Multipolar connect f XW REP 3m 61,- CAB/REP5 Multipolar connect f XW REP 5m 76,- XJ485 Serial interface TTL - RS485 XJ485 XR110C - XR120C - XR130C - XR140C - XR150C - XR0C XR170C - XR172C - XR530C - XR570C - XR572C - XR120D XR130D - XR140D - XR0D - XR170D - XR530D - XR563D XR570D from Controller 210,- CAB/RS02 Multipolar connect f XJ cm 73,- POWER MODULE FOR FANS - DIN RAIL - Input: 4 20mA Output: 500W XR PW 500 XR130C - XR140C - XR150C - XR0C XR170C - XR172C - XR530C - XR570C - XR572C 230Vac 476,- Name Available f models Meaning Surcharge OPTIONS Analog Output (4 20mA) XWREP Output XR130C - XR140C - XR150C - XR0C XR170C - XR172C - XR530C - XR570C - XR572C XR130C - XR140C - XR150C - XR0C XR170C - XR172C - XR530C - XR570C - XR572C = Yes 46,- = Yes 40,- 136 Ullstrøm-Fepo AS Kr. Augustsgt Oslo Tlf: Fax:
HACCP CONTROLLERS. Ullstrøm Fepo AS Kr. Augustsgt. 13-0164 Oslo Tlf: 23 15 71 50 - Fax: 23 15 71 51. MULTIFUNCTION CONTROLLERS- - 32 x 74 -
HACCP CONTROLLERS GRUPPE Model s Relay outputs Other Digital MULTIFUNCTION CONTROLLERS- - 32 x 74 - Double display 3 + 4 digits Operating range: NTC Probe: -40 110 C XR 720 C 8A XR 740 C XR 760 C MULTIFUNCTION
More informationOperating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC
HOJA TÉCNICA 1400H101 Edición 01 (02 de 08) www.ako.es GENERAL TECHNICAL SPECIFICATIONS Temperature range: -50ºC to +99ºC type: NTC Total accuracy ( + controller): ±1ºC lead extension with cable AKO-15586:
More informationElectronic Controller for Compressor Racks XC440C - XC440D. Instructions Manual
Electronic Controller for Compressor Racks XC440C - XC440D Instructions Manual INDEX 1. GENERAL WARNING 4 1.1 PLEASE READ BEFORE USING THIS MANUAL 4 1.2 SAFETY PRECAUTIONS 4 2. GENERAL DESCRIPTION 4 3.
More informationDixell. Electronic Controls Handbook September 2000. Programming Flow Charts & Parameter Lists for:
Dixell Electronic Controls Handbook September 2000 Programming Flow Charts & Parameter Lists for: XR100 Series - Refrigeration Controller XT Series - Heating & Cooling Controllers XC Series - Step Controllers
More informationEARTH LEAKAGE PROTECTION: CONTENTS
EARTH LEAKAGE PROTECTION: CONTENTS Earth Leakage Relays 128-130 Trip Circuit Supervision Relays 128-130 TEMPROTECT Protection and Distribution 1A to 6300A page 127 EARTH LEAKAGE PROTECTION ELR-1E The ELR-1E
More informationLocal PlantVisor. PlantWatch. Remote PlantVisor
PlantVisor Sistema Local PlantVisor PlantWatch Remote PlantVisor Solutions for: Data recording HACCP Printout Alarm management Tele Maintenance Powerful & integrated for Convenience Stores Petrol Station
More informationNL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module
NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module 1. General Description 1 2. General Warnings 1 3. Interface 2 4. Temp Alarms Setting 3 5. Programming 3 6. Light Management 4 7. Installation and
More informationSterowniki uniwersalne z serii IR32. This is a universal step control for low cost solutions
CAREL Sterowniki uniwersalne z serii IR32 This is a universal step control for low cost solutions Sterowniki uniwersalne z serii IR32 Mod.NTC Connection to temperature, humidity and pressure sensore (NTC,
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationZlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
More informationShort Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
More informationOptimize your simple machines... Modicon M218 Selection Guide
Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationWD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
More informationFX07 Field Controller
Product Bulletin FX07 Field Controller Issue Date May 5, 2011 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,
More informationFirmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
More informationLC/LCD ranges level controllers
GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice
More informationBuilding Control Solutions
Building Control Systems Building Control Solutions JaCreated by Honeywell March 14, 2014 customer.honeywell.com TO: FROM: Authorized System Distributors Authorized Controls Integrators Building Control
More informationNew generation......continuity, innovation, design
...continuity, innovation, design T e c h n o l o g y & E v o l u t i o n ...continuity, innovatio n, design Welcome to the new generation! The famous ir32 series of controllers has given rise to the new
More informationDQ61. Temperature Monitoring Unit for Transformers and Other Electrical Machines. User Manual (Hardware Rel. 2.0 - Firmware Rel. 1.3.
Temperature Monitoring Unit for Transformers and Other Electrical Machines DQ61 User Manual (Hardware Rel 20 - Firmware Rel 133) Rev 0114_en 28/12/2012 1 General Information 3 2 How to use this manual
More informationDCS Series 1 kw, 1.2 kw, & 3 kw
DCS Series 1 kw, 1.2 kw, & 3 kw AVAILABLE WITH LXI STANDARD COMPLIANT ETHERNET Applications Automotive Electronics Rackmount ATE System Battery Charging DCS Series DCS Series: 1 kw, 1.2 kw, & 3 kw DCS
More informationRegards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
More informationBIOMEDICAL REFRIGERATORS
BIOMEDICAL REFRIGERATORS U LT R A L O W F R E E Z E R S - L A B O R AT O R Y, P H A R M A C E U T I C A L A N D M E D I CA L R E F R I G E R AT I O N ARCTIKO CONTROLLER At Arctiko we have the customer
More informationPD 100A. Printing data system
PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep
More informationSplit Controller. User Manual SM-SS-F 2009/01/04
Split Controller SM-SS-F User Manual 2009/01/04 Table of contents 1. Parts illustration.... 1 2. Electrical technical data...... 2 3. Electrical connection...3 4. Assemble parts...4 4.1 Assemble the fixed
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationRZAHUC program version 1.1 Regulation for Reznor Air Handling Units
INSTALLATION INSTRUCTIONS OPTION 1xxx 1104_1000_EN Comfort Regulation (Carel pco) Detailed instructions RZAHUC program version 1.1 Regulation for Reznor Air Handling Units INDEX 1. Introduction... 4 1.1.
More informationProcess Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
More informationECP 208. Cold Rooms Controllers USER S MANUAL
ECP 208 Cold Rooms Controllers USER S MANUAL INDEX DESCRIPTION... 3 FUNCTIONING... 4 PARAMETERS SETTING... 4 FRONTAL SETTING CONTROLS... 4 MAIN FEATURES... 5 LAYOUT AND TERMINAL BLOCKS... 6 OPTIONS...
More informationGaiaMoto Programmable Differential Temperature Controller
GaiaMoto Programmable Differential Temperature Controller What is a GaiaMoto? Gaia The perspective that all living and non-living parts of the Earth function together to maintain an environment suitable
More informationFX07 Field Controller
Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,
More informationFieldbus slave modules with I/Os, DIO
140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO
More informationMonitoring,Telemaintenance,... HACCP. Innovative Supermarket solutions. Tecnologia ed Evoluzione
Monitoring,Telemaintenance,... HACCP Innovative Supermarket solutions Tecnologia ed Evoluzione For more compact systems, with the same management and control needs as larger areas, PlantWatch offers the
More informationProducts Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications
The ZigBee Plug & Play wireless Network for Building and Industrial Applications Energy Management Renewable Monitoring Environment Monitoring Open Modbus Integration Products Range Overview Products Range
More informationUSER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM
USER S GUIDE EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL The EE210 transmitter, available for wall or duct mounting, is designed for the highly accurate
More informationO C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
More informationTO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?
TO-PASS -FAQ- Remote Monitoring What is TO-PASS used for? TO-PASS modules are used as/for: Permanent online connection Fault detectors Remote data polling Data storage Telecontrol module What are the special
More information2 MODEL AND APPLICATION INFORMATION
A LOOK AT SERVICE SAFETY 2 MODEL AND APPLICATION INFORMATION I. Compressor Model Number Codes..... 10 II. Condensing Unit Model Number Codes.. 11 III. Serial Label Information.............. 12 IV. Basic
More informationOperating Instructions
CS101 CarSense Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the CS101 as a safety reversing or presence detection system. The CS101 requires that a vehicle be moving for
More informationHVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function
Specifications Supply Voltage 240VAC @ 0.07Amps or 24VAC @ 0.380Amps Relays 240V @ 12A max (resistive) / Comp1,2,3, Aux Ht, Rv O/B) Fuses (Equipment) 15 Amps Maximum 3AG Control Range Minus 10 to 50C Control
More informationA project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
More informationBuckeye Detection Systems Fixed Detection Systems Application Survey
Buckeye Detection Systems Fixed Detection Systems Application Survey Channel Partner Representative : Company Name: Representative: BDS Representative: Client Contact Information : Company Name: Company
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationUSB-500 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More informationHow To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)
100% electricity Digital multimeters and power analyzers series DIGITAL MULTIMETERS AND POWER ANALYZERS with backlit graphic LCD screen For the control of energy distribution systems detecting when problems
More informationCONTENTS General features Front panel and buttons Installation List of the working parameters to be checked before starting the unit
CONTENTS General features..... 1 Models available..... 1 Main features of the Infrared Series.... 2 Front panel and buttons..... 4 LED display Indicators..... 4 Keypad..... 5 Installation..... 6 Standard
More informationINTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a
More informationMONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products
MONITORING Measurement Sensors Dry contacts Logging Analysis, Alarms Various products XML/HTTP SNMP, E-mail GPRS/SMS Reports Graphs, Excel Alarms www.hw-group.com Measurement, Sensors Temperature Humidity
More informationMOTOR CONTROL IS OUR NATURE
MOTOR CONTROL IS OUR NATURE PRODUCT GUIDE CONTENTS Company Profile 4-5 Medium Voltage Products 1. HRVS-DN Medium Voltage Soft Starter 2. DriveStart IGBT Based Medium Voltage Soft Starter 3. HRVS-TX Medium
More informationMillenium Web Server
Web Control System Cooling management Water management Building management system Millenium Web Server freedom for professionals f r e e d o m f o r p r o f e s s i o n a l s Supervise your installations
More informationUSB-500 Series Stand-Alone, Low-Cost Data Loggers
Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use
More informationPLC GPRS NET Data Logger
GPRS NET Data Logger Mul Channels GPRS Wireless & Ethernet Network Transmission & Data Logging Upload Data via GPRS, SMS & Ethernet on schedule or alarm triggered Programmable data logging and upload interval
More informationConfigurable Events for APC Network Management Card
Configurable s for APC Network Management Card Table of Contents Silcon DP300E Series 3 Smart-UPS / Matrix 7 Symmetra 9 Symmetra 3-Phase 13 Environmental Monitor 21 Configurable s for APC Network Management
More informationMONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products
MONITORING Measurement Sensors Dry contacts Logging Analysis, Alarms Various products XML/HTTP SNMP, E-mail GPRS/SMS Reports Graphs, Excel Alarms www.hw-group.com Measurement, Sensors em e u e H m d ty
More information30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
More informationController board and power supply for vivimat III systems
Controller board and power supply for vivimat III systems Ref: VIVIMAT-3.0 The controller board and power supply vivimat 3.0, is the central core of the vivimat III home automation system. The vivimat
More informationDCP Fan Controller. Version 01/2009. The engineer s choice
Version 01/2009 The engineer s choice Index Page 1. Introduction... 3 2. Technical specification... 4 3. Connection diagrams... 9 4. Configuration... 10 5. Compatible ebm-papst Fan List... 11 2 1. Introduction
More informationUSB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More informationOXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system
Sistema autolimpiable Dissolved Oxygen Autoclean system Applications: - water treatment - activated sludge - de-nitrification - fish pond Install & forget For special applications, the D.O monitor can
More informationSYSTEMS CALL CENTER GLOBAL RETAIL SOLUTION XWEB5000 XCENTER XWEB3000 XWEB500 - XWEB500D XWEB300D
GLOBAL RETAIL SOLUTION Research, great experience, regulation and design innovation: these are the elements that allow Dixell to offer controllers and supervising systems that are in the forefront for
More information<IMG INFO> 396,8 211 8 ECH 200. Electronic Controller for mono and bicompressor
396,8 211 8 Electronic Controller for mono and bicompressor Chillers 1 CONTENTS 1 Contents...2 2 How to use this manual...5 3 Introduction...6 3.1 Models available...6 3.2 Components and accessories...7
More informationT-100-R Installation Guide
T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard
More informationLIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
More informationTrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
More informationMP-4000 Alarm List (Software version 2.4.3 or later)
Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.
More informationSERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER. PVI Industries, LLC 3209 Galvez Dr Fort Worth, Texas 76111 800-784-8326
SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER PVI Industries, LLC 3209 Galvez Dr Fort Worth, Texas 76111 800-784-8326 Page 1/ 24 PV500-41 10/2013 INDEX 1. TECHNICAL DATA 3 2. WIRING DIAGRAMS
More informationSilo Temperature probe. Silo thermometry. www.loreme.fr E 1 SILOTHERMOMETRY REV2B - 14/10/13
Silo Temperature probe Silo thermometry C www.loreme.fr SILOTHERMOMETRY E 1 REV2B - 14/10/13 FLEXIBLE PROBE FOR SILO TEMPERATURE MEASURE Type: SILOFLEX Easy and fast mounting To suspend or flanged Analog
More information026-1728 Rev 0 25-AUG-2011. ipro HVAC and Lighting Installation and Operation Manual
026-1728 Rev 0 25-AUG-2011 ipro HVAC and Lighting Installation and Operation Manual Retail Solutions 3240 Town Point Drive NW, Suite 100 Kennesaw, GA 30144 Phone: 770-425-2724 Fax: 770-425-9319 Table
More informationEDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
More informationMaterial test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
More informationDigital controller with alarm management XR40CX
1. CONTENTSGENERAL WARNING Digital controller with alarm management XR40CX 1.1 PLEASE READ BEFORE USING THIS MANUAL This manual is part of the product and should be kept near the instrument for easy and
More informationMulti DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE
Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication
More informationVIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS
VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS CEMB SPA Via Risorgimento, 9 Mandello del Lario (Lc), Italy stm@cemb.com www.cemb.com INSTRUMENT FOR MONITORING VIBRATIONS OF FANS INSTALLED IN ROAD
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationSOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
More informationAuto-tune PID. Temperature Controller BRAINCHILD FEATURES
Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog
More informationInwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
More informationLIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
More informationsite monitoring Kit Site Monitoring Kit User Manual we prove it.
site monitoring Kit 1 User Manual Site Monitoring Kit User Manual we prove it. 2 site monitoring Kit Content 1. Introduction 3 2. Content of the Site Monitoring Kit 4 3. Preparation 6 1. Positioning of
More informationDREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
More informationPROGRAMMABLE CONTROLLERS
C-PRO MICRO PROGRAMMABLE CONTROLLERS HARDWARE MANUAL CODICE 114CPRUHWE03 Important Please read these instructions carefully prior to installation and use, and follow all the precautions for installation
More informationGSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.
More informationIntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
More informationTABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
More informationHeating and Hot Water Services Controls General Technical Specification
Construction Services Heating and Hot Water Services Controls General Technical Specification Version 1.0 Environment Heating and Hot Water Services Controls General Technical Specification Contents 1.
More informationVroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
More informationSNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use
SNMP-1000 Intelligent SNMP/HTTP System Manager Features Monitors system fans, temperature, voltage, power supply, CPU fan, CPU temperature, Vcore, watchdog timer etc. Stand alone system monitoring, no
More informationTechnical Information
Date of last update: Oct-11 Ref: D7.8.4/1011/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors... 1
More informationGSM/3G UMTS/GPS/SMS Data Logger. The King Pigeon S262W S263W Data Logger inbuilt industrial GSM and 3G WCDMA
S262W S263W GSM/3G UMTS/GPS/SMS Data Logger The King Pigeon S262W S263W Data Logger inbuilt industrial GSM and 3G WCDMA module, GPS optional. channel Analog inputs (0-20mA,-20mA,0-5V) support Ultra-Low/Low/High/Ultra-High
More informationDiesel Generating Set
MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V
More informationMONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts
MONITORING A m 3 /s C Rh V J m/s F g/m 3 Pa kw Measurement Sensors Dry contacts Logging Analysis, Alarms Various products XML/HTTP SNMP, E-mail GPRS/SMS Reports Graphs, Excel Alarms www.hw-group.com Measurement,
More informationOverview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
More informationINSTALLATION MANUAL. Address card EKAC10B
INSTALLATION MANUAL 88 44 µchiller compact 70 64 4a 4b G G0 power supply G G0 power supply 50 5 50 5 4a 4b 5a 5b 4 5a 5b Installation manual READ THIS MANUAL ATTENTIVELY BEFORE STARTING UP THE UNIT. DO
More informationBR I Blood Bank Refrigerators
Technology for Life Medical SYSTEMS Technology for Life BR I Blood Bank Refrigerators +4 C 292.9707.50 08/2013 BIOMEDICAL REFRIGERATION Innovative and reliable refrigeration solutions compression Refrigerators,
More informationAlways on the Lookout Perfect Protection against Burglary
Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationFeatures and Benefits
Refrigeration 2 eatures and Benefits Based on IR32 Parameters Real Time lock ( RT ) Model Specific (defrost based on real time 7 day 24 hour) HAP (Hazard Analysis and ritical ontrol Point) Alarm Available
More informationNJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)
Safely into a new day Advanced modular FIRE ALARM CONTROL PANEL with additional functionality NJP-400A NJP-401A I m on FIRE (Bruce Springsteen) EN 54-2, EN 54-4 Cert No. 1124a DESCRIPTION OP-400A, NJP-400A,
More informationEBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING
EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING Cold Chain Monitoring The easy to use data loggers with USB connection monitor the temperature and/or humidity during transport and storage
More information