Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Size: px
Start display at page:

Download "Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment"

Transcription

1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHPPNG AND DELVERY TENS OF THOUSANDS OF N-STOCK TEMS EQUPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED LEASNG/MONTHLY RENTALS TAR CERTFED SECURE ASSET SOLUTONS SERVCE CENTER REPARS Experienced engineers and technicians on staff at our full-service, in-house repair center SM nstraview REMOTE NSPECTON Remotely inspect equipment before purchasing with our interactive website at Contact us: (888) 88-SOURCE WE BUY USED EQUPMENT Sell your excess, underutilized, and idle used equipment We also offer credit for buy-backs and trade-ins LOOKNG FOR MORE NFORMATON? Visit us on the web at for more information on price quotations, drivers, technical specifications, manuals, and documentation

2 FLUKE. For the benefit and convenience of its customers, Fluke Corporation (Fluke) has reproduced this copy of a manual which is no longer in production. This manual has not been edited or updated since the revision date shown on the lower left hand corner of the first page. Fluke will not be liable for any claims, losses or damages of any kind incurred by any user arising from use of this manual. Digital Multimeter nstruction Manual PN December 1991 Rev. 3, 5/97 O 1991, 1994,1997 Fluke Corporation. All rights resewed. Printed in U.S.A. All product names are trademarks of their respective companies. Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

3 LMTED WARRANTY & LMTATON OF LABLTY Each Fluke product is warranted to be free from defects in material and workrnanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke's opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available if produce is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repairlreplacement parts when product purchased in one country is submitted for repair in another country. Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke authorized service center or send the product, with a description of the difficulty, postage and insurance prepaid (FOB Destination), to the nearest Fluke authorized service center. Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). f Fluke determines that the failure was caused by misuse, alteration, accident or abnormal condition of operation or handling, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point). THS WARRANTY S BUYER'S SOLE AND EXCLUSVE REMEDY AND S N LEU OF ALL OTHER WARRANTES, EXPRESS OR MPLED, NCLUDNG BUT NOT LMTED TO ANY MPLED WARRANTY OF MERCHANTABLTY OR FTNESS FOR A PARTCULAR PURPOSE. FLUKE SHALL NOT BE LABLE FOR ANY SPECAL, NDRECT, NCDENTAL OR CONSEQUENTAL DAMAGES OR LOSSES, NCLUDNG LOSS OF DATA, WHETHER ARSNG FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELLANCE OR ANY OTHER THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. f any provision of this Warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. Fluke Corporation P.O. Box 9090 Everett WA Fluke Europe B.V. P.O. Box B.D. Eindhoven The Netherlands Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

4 MULTMETER SAFETY The Fluke 8840A Digital Multimeter has been designed and tested according to EC Publication 348. Safety Requirements for Electronic Measuring Apparatus. This manual contains information and warnings which must be followed to ensure safe operation and retain the meter in safe condition. Use of this equipment in a manner not specified here in may impair the protection provided by the equipment. Some common internationali electrical symbols used in this manual are shown below. - OFF (power). SWTCH POSTON 4 ON (power) SWTCH POSTON AC-ALTERNATNG CURRENT, 0 -- DC-DRECT CURRENT A 1 1 ETHER DC OR AC i - h DANGEROUS VOLTAGE EARTH GROUND SEE EXPLANATON N MANUAL SEE MANUAL FOR FUSE REPLACEMENT NFORMATON Before using the meter, read the following safety information carefully. n this manual, 'WARNNG," is reserved for conditions and actions that pose hazard (s) to the user; "CAUTON," is reserved for conditions and actions that may damage your meter. Avoid working alone. Follow all safety procedures for equipment being tested. nspect the test leads for damaged insulation or exposed metal. Check test lead continuity. Damaged leads should be replaced. Be sure the meter is in good operation condition. Select the proper function for your measurement. To avoid electrical shock, use caution when working above 60V dc or 25V ad RMS. Disconnect the live test lead before disconnection the common test lead. Disconnect the power and discharge high-voltage capacitors before testing in kn. When making a current measurement, turn the circuit power off before connecting the meter in the circuit. Check meter fuses before measuring transformer secondary or motor winding current. (See Section 6, "MANTE- NANCE.") An open fuse may allow high voltage build-up, which is potentially hazardous. Use clamp-on probes when measuring circuits exceeding 2 amps. Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

5 Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

6 SECTON GUDE ntroduction and Specifications... Operating nstructions... rn Remote Programming... Measurement Tutorial... F! Theory of Operation... Maintenance... rn List of Replaceable Parts... i!a Options and Accessories... E l Schematic Diagrams....El ndex Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

7 Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

8 Table of Contents SECTON TTLE PAGE 1 ntroduction and Specifications NTRODUCTON THE 8840A DGTAL MULTMETER OPTONS AND ACCESSORES SPECFCATONS Operating nstructions NTRODUCTON NSTUTiON nstalling the Power-Line Fuse Connecting to Line Power Adjusting the Handle Rack Mounting Kits OPERATNG FEATURES Power-Up Features...: Front and Rear Panel Features Display. Features Error Messages Overrange ndication Diagnostic Self-Tests Ranging AUTORANGE MANUAL RANGE Triggering CONTNUOUS TRGGER MODE EXTERNAL TRGGER MODE Reading Rates and Noise Rejection Automatic Settling Time Delay External Trigger nput (Option -05 Only) Sample Complete Output (Option -05 Only) MAKNG MEASUREMENTS nput Overload Protection Limits Measuring Voltage and Resistance Measuring Current Current Fuse Protection Offset Measurements EXTERNAL CLEANNG Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

9 Table of Contents SECTON TTLE PA& 3 Remote Programming NTRODUC'ON CAPABLTES BUS SET-UP PROCEDURE AN OVERVEW OF REMOTE OPERATON A NOTE ABOUT EXAMPLES DEVCE-DEPENDENT COMMAND SET Bn (Offset Gommands)... 3 Cn (Calibration Commands)... Dn (Display Commands)... Fn (Function Commands)... Get Commands GO (Get nstrument Configuration) G1 (Get SRQ Mask) G2 (Get Calibration Prompt) G3 (Get User-Defined Message) G4 (Get Calibration Status) G5 (Get AB Status) G6 (Get YW Status) G7 (Get Error Status) G8 (Get nstrument identification) N (Numeric Entry Command) Put Commands PO (Put nstrument Configuration) P1 (Put SRQ Mask) P2 (Put Calibration Value) User-Defined Message) Sn (Reading Rate Commands) Tn (Trigger Mode Commands) Wn (Terminator Commands) XO (Clear Error Register Command) Yn (Suffix Commands) ZO (Self-Test Command) * mevice-clear Command) ? (Single-Trigger Command) NPUT SYNTAX Definitions nput Processing Syntax Rules OUTPUT DATA Loading Output Data Types of Output Data Numeric Data and Error Messages MEASUREMENT DATA OVERRANGE NDCATON ERROR MESSAGES Status Data Output Priority l$ SERVCE REQUESTS The Serial Poll Register The SRQ Mask NTERFACE MESSAGES Address Messages b Universal Commands ) Addressed Commands TALK-ONLY MODE REMOTE CALBRATON Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

10 Table of Contents SECTON TTLE PAGE TMNG CONSDERATONS MMEDATE MODE COMMANDS EXAMPLE PROGRAMS Measurement Tutorial NTRODUCTON DC VOLTAGE MEASUREMENT Circuit Loading Error nput Bias Current Error RESSTANCE MEASUREMENT Wire Ohms Correcting for Test Lead Resistance in 2-Wire Ohms Wire Ohms Applications of the Ohms Functions TESTNG DODES TESTNG ELECTROLYTC CAPACTORS A PRECSON CURRENT SOURCE DC CURRENT MEASUREMENT REDUCNG THERMAL VOLTAGES AC VOLTAGE AND CURRENT MEASUREMENT True RMS Measurement Waveform Comparison Crest Factor AC-Coupled AC Measurements Combined AC and DC Measurements Bandwidth Zero-nput VAC Error Theory of Operation NTRODUCTON...; OVERALL FUNCTONAL DESCRPTON DETALED CRCUT DESCRPTON DC SCALNG VDC Scaling VDC Protection m.4 DC Scaling Analog Filter TRACWHOLD CRCUT Trackconfiguration Settling Configuration Hold Configuration Pre-Charge Configuration PRECSON VOLTAGE REFERENCE OHMS CURRENT SOURCE OHMS PROTECTON OHMS FUNCTONS Wire Ohms Wire Ohms A/D CONVERTER TirninglData Control Precision DAC AD Amplifier Bootstrap Supplies DSPLAY KEYBOARD DGTAL CONTROLLER iii Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE J

11 Table of Contents SECTON TTLE PAqE n-guard Microcomputer Function and Range Control AD Control and Computation Calibration Correction KeyboardDilay Control...' 5-15 Troubleshooting Modes Guard-Crossing Communication GUARD CROSSNG POWER SUPPLY P EEE-488 NTERFACE (OPTON -05) Out-Guard Microcomputer Guard Crossing Bus nterface Circuitry Signal Conditioning EEE-488 nterface Power Supply TRUE RMS AC (OPTON -09) VAC Scaling ma AC Scaling Frequency Response Trimming True RMS AC-to-DC Conversion Maintenance NTRODUCTON PERFORMANCE TEST Diagnostic Self-Tests DC Voltage Test AC Voltage Test (Option -09 Only) , 6-6 Resistance Test DC Current Test ' 6-8 AC Current Test (Option -09 Only) CALBRATON , 6-10 Basic Calibration Procedure NTAL PROCEDURE A/D CALlBRAnON \ OFFSET AND GAN CALBRATON HGH-FREQUENCY AC CALBRATON Advanced Features and Special Considerations STORNG VARABLE NPUTS CALBRATNG NDMDUAL RANGES VERFYNG CAJJBRATON ; ERASNG CALBRATON MEMORY... 6-lp TOLERANCE CHECK AC CALBRATON AT OTHER FREQUENCES OPTMZNG USE OF THE 5450A Remote Calibration TMNG CONSDERATONS... 6-l$ REMOTE ERASURE EXAMPLE CALBRATON PROGRAM DSASSEMBLY PROCEDURE Case Removal True RMS AC PCA Removal (Option -09)... 6-lj 6.30 EEE-488 nterface PCA Removal (Option -05 Only) Main PCA Removal Front Panel Disassembly REASSEMBLY PROCEDURE E NTERNAL FUSE REPLACEMENT k EXTERNAL TRGGER POLARTY SELEC1ON (Option -05 Only) Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

12 Table of Contents SECTlON TTLE PAGE EXTERNAL TRGGER POLARTY SELECTON (Option -05 Only) TROUBLESHOOTNG nitial Troubleshooting Procedure Diagnostic Self-Tests Self-Test Descriptions Digital Controller Troubleshooting N-GUARD MCROCOMPUTER SYSTEM n-guard Microcomputer Address Latch (U219) External Program Memory (XU222) Calibration Memory (U220) Relay Buffer (U201) to-8 Chip Select Decoder (U208) DSPLAY SYSTEM Display Control (U212) Bit Digit Driver (U215) to-8 Strobe Decoder (U213) Bit Segment Driver (U217) to-7 Segment Decoder (U216) Bit Digit Driver (U218) Hex nverter (U203) Hex nverter (U221) Quad OR Gate ('21 1) Keyboard Wiring ANALOG CONTROL SGNALS Evaluating Static Signals Evaluating Dynamic Signals DC Scaling Troubleshooting TracdHold Troubleshooting Ohms Current Source Troubleshooting Precision Voltage Reference Troubleshooting AP Converter Troubleshooting Power Supply Troubleshooting EEE-488 nterface Troubleshooting (Option -05) SERVCE POSTON DAGNOSTC PROGRAM True RMS AC Troubleshooting (Option.09) SERVCE POSTON MAJOR PROBLEMS MORE OBSCURE PROBLEMS Guard Crossing Troubleshooting NTERNAL CLEANNG Cleanhg Printed Circuit Assemblies Cleaning After Soldering List of Replaceable Parts NTRODUCTON HOW TO OBTAN PARTS MANUAL STATUS NFORMATON NEWER NSTRUMENTS SERVCE CENTERS Options and Accessories NTRODUCTON ACCESSORES Rack-Mount Kits (Y8834, Y8835 and Y8836) Shielded EEE-488 nterface Cables (Y8021. Y8022. and Y8023) v Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

13 Table of Contents SECTON Replacement Test Leads (TL7OA) Deluxe Test Lead Kits (Y8134) Slim-Flex Test Leads (Y8140) Temperature Probes (80T-150U and 80TK) RF Probes (85RF and 83RF) Current Shunt (805.10) Current Probes (Y8100, Y i-400 and 80i-600) High Voltage and 80K-40) NDEX Option 95 EEE-488 nterface... 80b1 Option -09 True RMS AC Schematic Diagrams Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

14 Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

15 List of lllustratilons FGURE TTLE PAGE 1.1 External Dimensions Line Voltage Selection Settings Adjusting the Handle Rack-Mount Kits nstalling the Single Rack Mount Kit Front Panel Features Rear Panel Features Typical Error Message Overrange ndication Measuring Voltage and Resistance Measuring Current EEE-488 Address Seiection Remote Operation Block Diagram Typical Command String Commands Which Correspond to the Front Panel Device-Dependent Command Set Output Data Format Trigger Selection Logic Diagram nterpretation of Messages Serial Poll Register Example Program: Taking 10 Readings Example Program: Taking Readings with Local Control Example Program: Using the Serial Poll Register Example Program: Record Errors During Selftest Example Programs: Using the BM PC Circuit Loading Error Calculation Measuring nput Bias Current Error Wire Ohms Measurement Wire Ohms Measurement Burden Voltage Error Calculation Waveform Comparison Chart Typical Crest Factors for Various Waveforms Combined AC and DC Measurement Reduction of Zero-nput Error Overall Functional Block Diagram DC Scaling (VDC and rna DC) TracWHold Amplifier Track/J3old Circuit Configurations Timing Diagram for One AD Cycle Precision Voltage Reference Ohms Current Source Ohms Scaling Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

16 List of llustrations FGURE TTLE 5.9. Analog-to-Digital Converter First Remainder-Store Period Autozero Period Vacuum Fluorescent Display Digital Controller Block Diagram Read/Write Timing Diagrams for nternal Bus Guard Crossing Circuit EEE-488 nterface Block Diagram True RMS AC Option Block Diagram True RMS AC-to-DC Converter Connections for Kelvin-Varley Voltage Divider First A/D Calibration Prompt Calibration Functions Optimizing Use of the 5450A Example A/D Calibration Program A Disassembly Front Panel Disassembly Removing the Display Window U202 Pin Diagram ~ 6.10 Waveforms for n-guard Troubleshooting Mode Waveforms for Display Logic Typical Dynamic Control Signals Typical Output Waveforms for TracWHold Circuit (TP103) Output of A/D Amplifier (TP101) Waveforms at U and U Typical Bus Data Line Waveform Waveforms at TP102 for Several nputs on 2V DV Range Calculating the A/D Reading From 'F102 Waveform Option -05 Service Position Option -09 Service Position Guard Crossing Test Waveforms nstalling Option nstalling Option Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

17 8840A Digital Multimeter Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

18 Section 1 S ntroduction and Specificatio~ NTRODUCTON This manual provides complete operating instructions and service information for the MA. f you wan1 to get started using your 8840A right away, proceed to the operating instructions in Section 2. f you intend to use the 8840A with the EEE-488 nterface (Option -05), read Sections 2 and THE 8840A DGTAL MULTMETER The Fluke 8840A Digital Multimeter is a highperformance digit instrument designed for generalpurpose bench or systems applications. Features of the 8840A include: Highly legible vacuum fluorescent display ntuitively easy front panel operation Basic dc accuracy of 0.005% for 1 year 2-wire and 4-wire resistance measurement DC current measurement Up to 100 readings per second ' Closed-case calibration (no internal adjustments) Built-in sdf-tests 1-3. omlots AND ACCESSORES A number of options and accegsories are available fc 8840A which can be easily installed at any time. options include: EEE-488 nterface (Optidn -03, featuring: Full programmability Simple and predictable command set Fast measurement throughput External Trigger inpuf connector Sample Complete output connector Automated calibration Low cost True RMS AC (Option featuring: AC voltage measurenient AC current measurement the The Accessories include a variety of rack mounting k.its, probes, test leads, and cables. Full information 2 lb out options and accessories can be found in Section SPECFCATONS Specifications for the 8840A are given in Table External dimensions are shown in Figure Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

19 introduction and Specifications SPECFCATONS Table 1-1. Specifications DC VOLTAGE nput Characteristtcs 1-2 RESOLUTON FULL SCALE NPUT RANGE 5% DGTS 5% DGTS 4% DGTS' RESSTANCE 200 mv mv 1 PV 10 pv 21 0,000 Mn 2V V 10 fl 100 pv 210,000 Mn 20V V 100 pv 1 mv 21 0,000 Mn 200V V 1 mv 10 mv 10 MQ 1 OOOV V 10 mv 100 mv 10 Mn '4% digits at the fastest reading rate. Accuracy NORMAL (S) READNG RATE... f (% of Reading + Number of C~unts).~ RANGE 24 HOUR 23f 1 *C1 90 DAY 23H C 1 YEAR 23&!j0C L Relative to calibration standards. Using Offset control. When in fast reading rate with internal trigger and transmitting data oqt of the EEE-488 ithterface, the 8840A display must be blanked (command Dl) to ensure stated accuracy. When offset control is not used, the number of counts are 5.7, and Qfor 24 hour, 90 day, and 1 year respeetiv MEDUM AND FAST RATES:... n medium rate, add2 counts to number of counts. n fast rate 3 counts for the number of counts. Operating Chamcterktlcs TEMPERATURE COEFFCENT... <f(0.0006% of Reading Count) per OC from O C to 1 and 28OC to SO0 C. MAXMUM NPUT... looov dc or peak ac on any range. NOSE RWECTJON Automatically optimized at power-up for 50, 60, or 400 HZ.... READNGS/ PEAK NM RATE SECOND1 FLTER NMRR2 SGNAL CMRR3 S 2.5 Analog & >98 db 20V or >40 db Digital 2x FS4 M 20 Digital >45 db lx FS >00 db F 100 None - x FS >60 db Reading rate with internal trigger and 60 Hz power line frequency. See "Reading Rates" for more deta Normal Mode Rejection Ratio, at 50 or 60 Hz f 0.1%. The NMRR for 400 Hz f 0.1% is 8b db in S rate and 3f in M rate. Common Mode Rejection Ratio at 50 or 60 HzM.l%, with 1 kn in series with either is >14 at dc for all reading rates. 20 volts or 2 times Full Scale whichever is greater, not to exceed 1000V. Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

20 ntroduction and Specifications SPECFCATONS Table 1-1. Specifications (cont) TRUE RMS AC VOLTAGE (OPTON -09) input Characteristics RESOLUTON FULL SCALE NPUT RANGE 5% DGTS 5% DGTS 4% DGTS* MPEDANCE 200 mv mv N 10 fl 1 Mi2 2V V 10 pv 100 pv shunted 20V V 100 pv 1 mv by 200v V 1 rnv 10 mv <00 pf 700V V 10 mv 100 mv '4% digits at the fastest reading rate. Accuracy NORMAL (S) READNG RATE &(Oh of Reading + Number of Co~nts).~ For sinewave inputs 210,000 counts1. FREQUENCY (Hz) 24 HOURS2 23f 1 O C 90 DAY 23fS C 1 YEAR 23fS C l For sinewave inputs between 1,000 and counts, add to Numbergf Counts 100 counts forfrequencies 20 Hz to 20 khz, 200 counts for 20 khz to 50 khz, and 500 counts for 50 khz to 100 khz. Relative to calibration standards. When in fast reading rate with internal trigger and transmitting data out of the EEE-488 interface, the 8840A display must be blanked (command Dl) to ensure stated accuracy. MEDUM AND FAST READNG RATES... n medium rate, add 50 counts to number of counts. n fast rate the specifications apply for sinewave inputs counts and >00 Hz. NONSNUSODAL NPUTS For nonsinusoidal inputs 210,000 counts with frequency components G00 khz, add the following YO of reading to the accuracy specifications. FUNDAMENTAL FREQUENCY CREST FACTOR TO TO Hz to 20 khz Hz to 45 Hz and 20 khz to 50 khz Operating Characteristics MAXMUM NPUT V rms, looov peak or2x 107Volts-Hertz product (whichever is less) for any range. Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

21 ntroduction and Specifications SPECFCATONS Table 1-1. Specifications (cont) TEMPERATURE COEFFCENT... +(% of Reading + Number of Counts) per "C, 0 C to 18 C and 28 C to 50 C. FOR FREQUENCY N HERTZ NPUTS 20-20K 20K-50K 50K - 100K 21 0,000 counts ,000 counts L COMMON MODE REJECTON... >60 db at 50 or 60 Hz with 1 kq in either lead. CURRENT nput Characteristic 1 RANGE FULL SCALE RESOLUTON 5% DGTS 5% DGTS 4% DGTS* i ma ma 10 PA 100 pa - *4% digits at the fastest reading rate. DC Current Accuracy NORMAL (S) READNG RATE... +(% of Reading + Number of Counts).' 1 90 DAYS C 1 YEAR C L 1A >1A MEDUM AND FAST READNG RATES..Jn medium reading rate, add 2 counts to number of counts. n fast reading rate, use 2 counts for number of counts. ' When in fast reading rate with internal trigger and transmitting data out of the EEE-488 interface, the 8840A display must be blanked (command Dl) ot ensure stated accuracy. AC Current Accuracy (Option -09) NORMAL (S) READNG RATE... +(% of Reading + Number of Counts).' 1 Year, 23 k 5"C, for sinewave inputs 210,000 counp * Typically 20 khz FREQUENCY N HERTZ K* ** ** ** ** Add 100 counts for sinewave inputs between 1000 and 10,000 counts. When in fast reading rate with internal trigger and transmitting data out of the EEE-488 interface, L Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

22 introduction and Specifications SPECFCATONS Table 1-1. Specifications (ant) MEDUM AND FAST READNG RATES... n medium rate, add 50 counts to number of counts. n fast reading rate, for sinewave inputs counts and frequencies >00 Hz, the accuracy is f (0.4% of reading + 30 counts). NONSNUSODAL NPUTS... For nonsinusoidal inputs 210,000 counts with frequency components G00 khz, add the following % of reading to the accuracy specifications. FUNDAMENTAL * FREQUENCY 1.0TO 1.5 CREST FACTOR 1.5 TO TO Hz to 5 khz Hz to 45 Hz Operating Characteristics TEMPERATURE COEFFCENT... Less than 0.1 x accuracy specification per OC from O C to 18OC and 28OC to 50 C. MAXMUM NPUT... 2A dc or rms ac. Protected with 2A, 250V fuse acc&ible at front panel, and internal 3A, 600V fuse. BURDEN VOLTAGE... 1V dc or rms ac typical at full scale. RESSTANCE nput Characterktlcr RANGE kn 20 kn 200 kn mkn 20 Mi2 FULL SCALE 5% DGTS 5?4 DGTS 4% DGTS* kr kn kn rn MR *4H digits at the fastest reading rate. Accuracy 1 rnn 10 mr 100 rnr f2 1 OR loor RESOLUTON NORMAL (S) READNG RATE... i(% of Reading + Number of count^)'.^ - 10 mr 100 mi2 1R 1 OR 1 oon 1 kr CURRENT THROUGH UNKNOWN 1 ma 1 ma PA 5 PA 0.5 pa 1 RANGE 24 HOUR 2333 O C2 90 DAY 23f5OC 1 YEAR 23f5OC 200SL3 2kn 20 kn 200 W kn 20 MR L, 'Within one hour of zero, using offset control. Relative to calibration standard ' Applies to 4-wire ohms only. When in fast reading rate with internal trigger and transmitting data out of the EEE-488 interface, the 8840A display must be blanked (command Dl) to ensure stated accuracy: When offset control is not used, the number of counts are 5.7, and 9 for 24 hour, 90 day, and 1 year respectively. Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

23 ntroduction and Specifications SPECFCATONS Table 1-1. Specifications (eont) Accuracy, cont MEDUM AND FAST READNG RATES... n medium rate,add2 counts to thenumberof countsforthe200h tnrough 200 kn ranges and 3 counts for the 2000 kn and 20 Mf) ranges. n fast reading rate, use3 counts forthe number of count$ for the 200Q range, and 2 counts for all other ranges. TEMPERATURE COEFFCENT... Less than 0.1 x accuracy specification per OC from O C to 18*$ and 28OC to 50 C. MEASUREMENT CONFGURATON... 2-wire or 4-wire. OPEN CRCUT VOLTAGE... Less than 6.5V on the 2002) through 200 kfl ranges. Lessthan 13V on the 2000 kn and 20 Ms2 ranges. NPUT PROTECTON... To 300V rms. READNG RATES READNG RATES WTH NTERNAL TRGGER... (readings per second). RATE 50 HZ POWER LNE FREQUENCY' 60 HZ 400HZ S M F Sensed automatically at power-up. AUTOMATC SETTLNG TME DELAY Time in milliseconds from single trigger to start of A/D conversion, Autorange off. r FUNCTON RANGE READNG RATE S M F NUMBER OF COUNTS FROM FNAL VALUE1 VDC VAC ma DC ma AC Ohms 200 mv 2V-10WV All 2000 ma 2000 ma 200n 2 ~ 2 20 ks2 200 kn 2000 kr 20 Mn (Note 2) 5 30 (Note 2) Difference between first reading and final value for an in-range step change coincident with trigger. 2. For slow reading rate. 50 counts for medium rate; 10 counts for fast rate. Artisan Technology Group - Quality nstrumentation... Guaranteed (888) 88-SOURCE

i410/i1010 AC/DC Current Clamp

i410/i1010 AC/DC Current Clamp /i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive

More information

Calibration Information

Calibration Information 360 Calibration Information Introduction This document provides the following information for the 360 (hereafter referred to as the Meter or UUT): Safety information Symbols Specifications Maintenance

More information

T5-600 / T Electrical Tester

T5-600 / T Electrical Tester T5-600 / T5-1000 Electrical Tester Instruction Sheet W Read First: Safety Information Use the tester only as specified in this Instruction Sheet, otherwise the protection provided by the tester may be

More information

Calibration Manual. Clamp Meter

Calibration Manual. Clamp Meter 373 Clamp Meter Calibration Manual December 2010 2010 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

More information

AutoRanging Digital MultiMeter

AutoRanging Digital MultiMeter Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

The following table shows the symbols used on the product and/or in this manual. Important Information. Refer to the manual.

The following table shows the symbols used on the product and/or in this manual. Important Information. Refer to the manual. i3000s/ AC Current Probe Instruction Sheet Introduction The i3000s 24 Flex, i3000s 36 Flex, and AC Current Probes (hereafter referred to as the Probe ) are used with oscilloscopes, digital multimeters,

More information

User Manual. CDM250 Digital Multimeter 070-6736-03

User Manual. CDM250 Digital Multimeter 070-6736-03 User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this

More information

Fluke 8808A Digital Multimeter Extended Specifications

Fluke 8808A Digital Multimeter Extended Specifications Fluke 8808A Digital Multimeter Extended Specifications Making measurements is as simple as pushing a button The Fluke 8808A 5.5 digit multimeter has a broad range of functions, measuring volts, ohms and

More information

323/324/325. Calibration Manual. Clamp Meter

323/324/325. Calibration Manual. Clamp Meter 323/324/325 Clamp Meter Calibration Manual February 2013 2012 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective

More information

Manual Ranging MultiMeter

Manual Ranging MultiMeter Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!

More information

True RMS Bench Multimeter 5492B

True RMS Bench Multimeter 5492B Data Sheet 5492B The B&K Precision model 5492B is a versatile 5½-digit, 120,000-count bench multimeter suitable for applications in education, service repair, and manufacturing. The instrument enhances

More information

10 Multimeter. Users Manual

10 Multimeter. Users Manual 10 Multimeter Users Manual 1991-2001 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. 10 MULTIMETER m m Mk SELECT RANGE OFF VDC VAC

More information

True-rms Remote Display Digital Multimeter

True-rms Remote Display Digital Multimeter Getting Started Manual 233 True-rms Remote Display Digital Multimeter PN 3465366 September 2009 2009 Fluke Corporation. All rights reserved. Printed in USA. Specifications are subject to change without

More information

User s Guide. 400A AC Clamp Meter. Model MA200

User s Guide. 400A AC Clamp Meter. Model MA200 User s Guide 400A AC Clamp Meter Model MA200 Introduction Thank you for selecting the Extech MA200 AC Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Diode Test, and Continuity.

More information

MICROMAPPER. Users Manual. LAN Wiremap Checker

MICROMAPPER. Users Manual. LAN Wiremap Checker TM MICROMAPPER LAN Wiremap Checker Users Manual (English) November 00, Rev., 9/0 00-00 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. i LIMITED

More information

User's Guide. Model and Single Output Laboratory Grade Switching DC Power Supply

User's Guide. Model and Single Output Laboratory Grade Switching DC Power Supply User's Guide Model 382275 and 382276 Single Output Laboratory Grade Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 382275 Single Output Laboratory Grade DC Power

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

True RMS Multimeter. Owner's Manual. Model No Safety Operation Maintenance Español

True RMS Multimeter. Owner's Manual. Model No Safety Operation Maintenance Español Owner's Manual True RMS Multimeter Model No. 81077 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

OPERATING INSTRUCTIONS MODEL 810 HIGH VOLTAGE POWER SUPPLY

OPERATING INSTRUCTIONS MODEL 810 HIGH VOLTAGE POWER SUPPLY OPERATING INSTRUCTIONS MODEL 810 HIGH VOLTAGE POWER SUPPLY Introduction The Model 810 High Voltage Power Supply is a self-contained unit that produces a variable high voltage output at low current levels.

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

Multifunction Process Calibrator

Multifunction Process Calibrator 725 Multifunction Process Calibrator Product Overview PN 1549644 English January 2000 Rev.2, 8/05 2000-2005 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their

More information

TRUE RMS AUTORANGING DIGITAL MULTIMETER. Model AX-155 INSTRUCTION MANUAL

TRUE RMS AUTORANGING DIGITAL MULTIMETER. Model AX-155 INSTRUCTION MANUAL TRUE RMS AUTORANGING DIGITAL MULTIMETER Model AX-155 INSTRUCTION MANUAL SAFETY WARNINGS The following safety information must be observed to insure maximum personal safety during the operation at this

More information

DIGITAL MULTIMETER USER S MANUAL

DIGITAL MULTIMETER USER S MANUAL DIGITAL MULTIMETER USER S MANUAL CONTENTS 1. SAFETY INFORMATION 1 2. DESCRIPTION.3 3. OPERATING INSTRUCTION.6 3.1 Measuring voltage..6 3.2 Measuring current..6 3.3 Measuring frequency.6 3.4 Measuring resistance.7

More information

User's Guide. True RMS Industrial Multimeter

User's Guide. True RMS Industrial Multimeter User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

73 Series III Multimeter

73 Series III Multimeter 73 Series III Multimeter Instruction Sheet Read First: Safety Information W To avoid damage to the meter, electric shock or injury: Never use the meter if the meter or test leads look damaged. Be sure

More information

Manual Ranging Multimeter Extech 410

Manual Ranging Multimeter Extech 410 User's Guide Manual Ranging Multimeter Extech 410 Introduction Congratulations on your purchase of the Extech 410 (part number EX410) Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,

More information

Current Probes. User Manual

Current Probes. User Manual Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall

More information

DT830 Series 3 1/2 Digital Multimeter

DT830 Series 3 1/2 Digital Multimeter DT830 Series 3 1/2 Digital Multimeter Owner's operation manual for 830 series Read this owner's manual thoroughly before use D C V 20 1000 OFF 750 A C V µ D C A 0m 0µ m B 0k E k E B C C E E N P N P N P

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR

More information

True RMS Digital Multimeter

True RMS Digital Multimeter User s Guide True RMS Digital Multimeter Model 22-816 Introduction Congratulations on your purchase of Extech s 22-816 true rms Digital Multimeter. This autoranging meter measures AC/DC Voltage, AC/DC

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011 Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

Ground Resistance Clamp-On Tester

Ground Resistance Clamp-On Tester User s Manual Ground Resistance Clamp-On Tester MODEL 382357 Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants the basic instrument to be free of defects in parts and workmanship for one

More information

True RMS Bench Multimeters 2831E and 5491B

True RMS Bench Multimeters 2831E and 5491B Data Sheet True RMS Bench Multimeters and True RMS Bench Multimeters with Dual Display The B&K Precision models and are versatile and dependable bench multimeters suitable for applications in education,

More information

FREQUENCY RESPONSE ANALYZERS

FREQUENCY RESPONSE ANALYZERS FREQUENCY RESPONSE ANALYZERS Dynamic Response Analyzers Servo analyzers When you need to stabilize feedback loops to measure hardware characteristics to measure system response BAFCO, INC. 717 Mearns Road

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

AC/DC Clamp Meter. Owner's Manual. Model No. 82369. Safety Operation Maintenance Español

AC/DC Clamp Meter. Owner's Manual. Model No. 82369. Safety Operation Maintenance Español Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

Pen Multimeter with Voltage Detector

Pen Multimeter with Voltage Detector Owner's Manual Pen Multimeter with Voltage Detector Model No. 82354 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation

More information

Earth Ground Clamp. Users Manual

Earth Ground Clamp. Users Manual 1630 Earth Ground Clamp Users Manual PN 2729710 October 2006 2006 Fluke Corporation, All rights reserved. Printed in China All product names are trademarks of their respective companies. LIMITED WARRANTY

More information

HVAC Clamp Meter. Users Manual

HVAC Clamp Meter. Users Manual 902 HVAC Clamp Meter Users Manual PN 2547887 May 2006 Rev. 1, 3/07 2006-2007 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies. LIMITED

More information

Installation, Operation & Service Manual

Installation, Operation & Service Manual Installation, Operation & Service Manual 0RQLWRU Pulse Monitor Software Version 1 0 1 Pulse Monitor Card Software Revision 1 4 0 Pulse Monitor Card Product Revision 0 1 0 0 February, 2007 Copyright 2007,

More information

Multimeter with Temperature

Multimeter with Temperature 16 Multimeter with Temperature P Read First: Safety Information Instruction Sheet To ensure that the meter is used safely, follow these instructions: Do not use the meter if the meter or test leads appear

More information

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &

More information

DC/AC CLAMP METER. Model CM-01 USERS MANUAL PROVA INSTRUMENTS INC.

DC/AC CLAMP METER. Model CM-01 USERS MANUAL PROVA INSTRUMENTS INC. DC/AC CLAMP METER Model CM-01 USERS MANUAL PROVA INSTRUMENTS INC. EN 61010-2-032 CAT II 600V CAT III 300V Pollution Degree 2 SYMBOLS showed on the clamp meter or in this manual: Caution, risk of danger.

More information

PagePac PAGEPAL V-5335700

PagePac PAGEPAL V-5335700 PagePac Issue 3 by PAGEPAL V-5335700 INTRODUCTION The PagePal unit interfaces most telephone systems (PBX, KTS, Centrex) to virtually any public address audio system. In addition, PagePal furnishes inputs

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121309B OWNERS

More information

LOXONE 12 Channel Amplifier

LOXONE 12 Channel Amplifier LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room

More information

Item # AC Inverter 700W USB. User s Manual

Item # AC Inverter 700W USB. User s Manual Item #2016-6 AC Inverter 700W USB User s Manual User s Manual Read before using this equipment Thank you for purchasing the Slim Line 700 Watt USB Inverter. With minimal care and proper treatment it will

More information

Seven function digital multimeter

Seven function digital multimeter Seven function digital multimeter 98025 Set up And Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com

More information

SAFETY INFORMATION CONTENTS PAGE

SAFETY INFORMATION CONTENTS PAGE CONTENTS PAGE SAFETY INFORMATION... 1 SYMBOL EXPLANATION. 2 SAFETY PRECAUTIONS.. 2 MAINTENANCE.. 4 GENERAL DESCRIPTION 4 PANEL DESCRIPTION.. 5 FORWARD LAYOUT.. 8 OPERATING INSTRUCTIONS. 9 SPECIFICATIONS..

More information

PS3000 Weighing Indicator USER GUIDE

PS3000 Weighing Indicator USER GUIDE PS3000 Weighing Indicator USER GUIDE Edition: 08-06-2012 Safety Instruction WARNING Calibration, inspection, and maintenance of the indicator must be performed by a qualified technician. WARNING The indicator

More information

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

Ground Resistance Clamp On Tester

Ground Resistance Clamp On Tester USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground

More information

80T-150UA. Universal Temperature Probe. Instruction Sheet

80T-150UA. Universal Temperature Probe. Instruction Sheet 80T-150UA Universal Temperature Probe Instruction Sheet 80T-150U TEMPERATURE PROBE C F OFF Introduction The Model 80T-150UA Universal Temperature Probe is a self-contained temperature-to-voltage converter.

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

User's Guide. Pen Multimeter with Voltage Detector Model Introduction

User's Guide. Pen Multimeter with Voltage Detector Model Introduction User's Guide Pen Multimeter with Voltage Detector Model 381676 Introduction Congratulations on your purchase of the Extech Model 381676. This instrument provides AC/DC Voltage, Resistance, Diode, & Continuity

More information

Users Manual. ProcessMeter

Users Manual. ProcessMeter 787 ProcessMeter Users Manual April 1997, Rev.3, 12/01 1997, 1898, 2000, 2001 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. LIMITED

More information

UT202A Operating Manual. Contents

UT202A Operating Manual. Contents Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols

More information

Model 1756 Test Lead Kit

Model 1756 Test Lead Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you

More information

Loop Calibration and Maintenance

Loop Calibration and Maintenance Loop Calibration and Maintenance Application Note Introduction Process instrumentation requires periodic calibration and maintenance to ensure that it is operating correctly. This application note contains

More information

MiniTec TM Series Manual Ranging Mini MultiMeter Model MN35 USER MANUAL

MiniTec TM Series Manual Ranging Mini MultiMeter Model MN35 USER MANUAL MiniTec TM Series Manual Ranging Mini MultiMeter Model MN35 USER MANUAL Introduction Congratulations on your purchase of Extech s MN35 Manual Ranging Multimeter. This meter measures AC/DC Voltage, DC Current,

More information

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Getting Started Getting Started with the Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 You only need a few minutes to get started

More information

PICOTEST. M3500A 6.5 Digit Digital Multimeter. User s Manual

PICOTEST. M3500A 6.5 Digit Digital Multimeter. User s Manual PICOTEST M3500A 6.5 Digit Digital Multimeter User s Manual Printed date: 02/2009 M3500A DMM 2 User s Manual Table of Contents 1 GENERAL INFORMATION... 6 1.1 FEATURE OVERVIEW... 6 1.2 WARRANTY INFORMATION...

More information

AC / DC POWER CLAMP MULTIMETER NI349PR. Manual

AC / DC POWER CLAMP MULTIMETER NI349PR. Manual AC / DC POWER CLAMP MULTIMETER NI349PR Manual 1. AC+DC 400/1200KW, auto-range 2. DC 2500A, AC 2100A, and AC/DC 600V. 3. φ55 mm diameter jaw. 4. One touch zero for DCA,DCW adjustment. 5. Auto-range for

More information

DDC864 DIGITAL DOWNCONVERTER 1. 2 FRONT PANEL CONTROLS and INDICATORS 12 POSITION RACK MOUNT POWER SUPPLY DDC864. Figure 1 DOWNCONVERTER

DDC864 DIGITAL DOWNCONVERTER 1. 2 FRONT PANEL CONTROLS and INDICATORS 12 POSITION RACK MOUNT POWER SUPPLY DDC864. Figure 1 DOWNCONVERTER TM DIGITAL DOWNCONVERTER 1 2 FRONT PANEL CONTROLS and INDICATORS 12 POSITION RACK MOUNT SUPPLY F1 F2 SUPPLY PS8 F3 F4 DOWNCONVERTER The R.L. Drake is a low noise downconverter designed for translating

More information

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions. INTRODUCTION The Decimator ProRackG guitar noise reduction system defines a new standard for excellence in real time noise reduction performance. The Decimator ProRackG was designed to provide the maximum

More information

BACnet Automation Interface Module (Network Version)

BACnet Automation Interface Module (Network Version) Sense +V Tx Rx LAN LINK Over ARCNET KBaud BACnet Rx BACnet Tx Archive Valid Port S Tx Port S Rx Low Battery Network- Enhanced Access Default MSTP PTP = Download Required on Rnet and Port S IP Address IP

More information

Keysight U1253B True RMS OLED Multimeter

Keysight U1253B True RMS OLED Multimeter Keysight U1253B True RMS OLED Multimeter Quick Start Guide Keysight U1253B True RMS OLED Multimeter Quick Start Guide The following items are included with your multimeter: Silicone test leads 4 mm probes

More information

Two and Three Element Speed Switches

Two and Three Element Speed Switches SECTON N T E RN A TtONA Speed Supersedes EG 70-12B and EG 70-12C Both Dated December 1984 Two and Three Element Speed SWA 675 SWA 675 A-1 Pr,/led in USA :,sued J_rlu_ry 1991 SECTON Speed NTERNATONAL NTRODUCTON

More information

Instructions A622 100 Amp AC/DC Current Probe 070-8883-03

Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,

More information

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide Agilent U1253B True RMS OLED Multimeter Quick Start Guide The following items are included with your multimeter: Silicone test leads 4 mm probes Alligator clips Printed Quick Start Guide Rechargeable 7.2

More information

Extech EX411 EX 411 Professional Multimeter Extech EX411-NIST True RMS Professional MultiMeter

Extech EX411 EX 411 Professional Multimeter Extech EX411-NIST True RMS Professional MultiMeter User's Guide Extech EX411 EX 411 Professional Multimeter Extech EX411-NIST True RMS Professional MultiMeter True RMS Multimeter Extech 411 Introduction Congratulations on your purchase of the Extech 411

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

Installation and Operation Guide for PD4500 Series Power Control Centers

Installation and Operation Guide for PD4500 Series Power Control Centers Installation and Operation Guide for PD4500 Series Power Control Centers Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as

More information

BC-8000 Field Calibration Procedure 55 AMP

BC-8000 Field Calibration Procedure 55 AMP BC-8000 Field Calibration Procedure 55 AMP CF1_FIELDCAL_BC8000 Revised 9/8/2012 Charger section can be used on a BC-9000 Version 1.00 INTRODUCTION: The BC-8000 Battery Capacity Analyzer and Charger will

More information

User's Guide. Model W 3-in-1 Switching DC Power Supply

User's Guide. Model W 3-in-1 Switching DC Power Supply User's Guide Model 382260 80W 3-in-1 Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 80W 3-in-1 Switching DC Power Supply. The Model 382260 has three output ranges

More information

Models CT-001, CT-002 Owner s Manual

Models CT-001, CT-002 Owner s Manual Automatic Chicken Coop Door Safe, Happy Hens Models CT-001, CT-002 Owner s Manual Version. 5.9 CT-001, CT-002 Copyright 2014-2015 Coop Tender www.cooptender.com Table of Contents Product Description...

More information

2000 6½-Digit Multimeter

2000 6½-Digit Multimeter 13 built-in measurement functions 2000 readings/second at 4½ digits Optional scanner cards for multipoint measurements IEEE-488 and RS-232 interfaces Fluke 8840/42 command set Ordering Information 2000

More information

80T-150UA. Universal Temperature Probe. Instruction Sheet

80T-150UA. Universal Temperature Probe. Instruction Sheet 80T-150UA Universal Temperature Probe Instruction Sheet 80T-150U TEMPERATURE PROBE C F OFF Introduction The Model 80T-150UA Universal Temperature Probe is a self-contained temperature-to-voltage converter.

More information

Manatronics 48V / 200 Amp Load

Manatronics 48V / 200 Amp Load Manatronics 48V / 200 Amp Load For Battery Discharge testing and Power Supply testing 30 th Jan. 2008 Model No. BD 12-48P Product Datasheet 48V / 200 Amp Electronic Load Features: Quality Product Rugged

More information

Water Leak Detection System

Water Leak Detection System Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright

More information

Models 175, 177, 179. True RMS Multimeters. Users Manual

Models 175, 177, 179. True RMS Multimeters. Users Manual Models 175, 177, 179 True RMS Multimeters Users Manual October 2000 (English), Rev 1, 7/01 2000-2001 Fluke Corporation. All rights reserved. Printed in USA. Lifetime Limited Warranty Each Fluke 175, 177,

More information

INSTRUCTION MANUAL CM-600 CM-650. Clamp-on Meters

INSTRUCTION MANUAL CM-600 CM-650. Clamp-on Meters INSTRUCTION MANUAL CM-600 CM-650 Clamp-on Meters Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. 99945550 2008 Greenlee Textron

More information

ABCs of DMMs Multimeter features and functions explained Application Note

ABCs of DMMs Multimeter features and functions explained Application Note ABCs of DMMs Multimeter features and functions explained Application Note Digital multimeters offer a wide selection of features. Choosing the right meter for the job can be challenging unless you know

More information

PS 155 WIRELESS INTERCOM USER MANUAL

PS 155 WIRELESS INTERCOM USER MANUAL PS 155 INTERFACE TO SIMPLEX WIRELESS INTERCOM USER MANUAL Issue 2011 ASL Intercom BV DESIGNED AND MANUFACTURED BY: ASL INTERCOM BV ZONNEBAAN 42 3542 EG UTRECHT THE NETHERLANDS PHONE: +31 (0)30 2411901

More information

www.burntec.com User's Guide Integrating Sound Level Datalogger Model 407780

www.burntec.com User's Guide Integrating Sound Level Datalogger Model 407780 User's Guide Integrating Sound Level Datalogger Model 407780 Introduction Congratulations on your purchase of the Extech 407780 Integrating Sound Level Meter. The 407780 with programmable integrating time

More information

Contents. Safety Warnings... 1

Contents. Safety Warnings... 1 Contents Safety Warnings... 1 Unpacking the GQ600... 1 Introduction... 2 GQ600 Filter Characteristics... 2 1/3 Octave Centre Frequencies... 4 Front Panel Functions... 5 Rear Panel Functions... 6 Specifications...

More information

DIGITAL + ANALOGUE HIGH VOLTAGE INSULATION TESTER

DIGITAL + ANALOGUE HIGH VOLTAGE INSULATION TESTER DIGITAL + ANALOGUE HIGH VOLTAGE INSULATION TESTER CONTENTS CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DURING USE 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 4 2. DESCRIPTION 6 2.1 NAMES OF COMPONENTS 7

More information

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel) SureGrip TM 80PK-24 Air Temperature Probe Instruction Sheet XWWarning To avoid electrical shock, do not use this probe when voltages exceeding 24 V ac rms or 60 V dc are present. The probe tip is electronically

More information

1.44 kw Programmable DC Power Supplies XLN Series

1.44 kw Programmable DC Power Supplies XLN Series Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

OPERATION MANUAL. Model : DW-6063. 99.99 W x 0.01 W, 520.0 W x 0.1 W Power factor, ACV, ACA WATT METER

OPERATION MANUAL. Model : DW-6063. 99.99 W x 0.01 W, 520.0 W x 0.1 W Power factor, ACV, ACA WATT METER 99.99 W x 0.01 W, 520.0 W x 0.1 W Power factor, ACV, ACA WATT METER Model : DW-6063 Your purchase of this WATT METER marks a step forward for you into the field of precision measurement. Although this

More information

Part Number Analog Wideband Air/Fuel Ratio Gauge

Part Number Analog Wideband Air/Fuel Ratio Gauge Part Number 30-5130 Analog Wideband Air/Fuel Ratio Gauge Figure 1. Wiring Schematic AEM Gauge-Type UEGO Controller Parts 1 x 35-5130(B/W) UEGO Gauge Assembly 1 x 30-2001 UEGO Sensor 1 x 35-8535 Install

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

This Datasheet for the IC660BBA100. Block 115Vac Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA100. Block 115Vac Analog 4 Inputs / 2 Outputs. This Datasheet for the IC0BBA00 Block 5Vac Analog Inputs / Outputs http://www.cimtecautomation.com/parts/p--ic0bba00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-0

More information

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc.

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc. Quick Guide DS1000CA Series Oscilloscope Aug. 2011 Technologies, Inc. Guaranty and Declaration Copyright 2011 Technologies, Inc. All Rights Reserved. Trademark Information is a registered trademark of

More information

CT-001, CT-001-Solar Owner s Manual

CT-001, CT-001-Solar Owner s Manual Automatic Chicken Coop Door Safe, Happy Hens CT-001, CT-001-Solar Owner s Manual CT-001, CT-001-Solar Rev. 2.7 Copyright 2014-2015 Coop Tender www.cooptender.com Table of Contents Product Description...

More information

3M Wrist Strap and Footwear Tester 740. User s Guide

3M Wrist Strap and Footwear Tester 740. User s Guide 3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6

More information