1 Eastridge mall San Jose, California TENANT DESIGN CRITERIA

2 Table of Contents Letter of Introduction 1 Center Address: 2 Local Utility Agencies 2 Landlord Required Contractors 3 Lower Level Plan 4 Upper Level Plan 5 Site Plan 6 Tenant Submissions and Permit Requirements 7 Landlord s Address for Document Submission 7 Document Submission 7 Required Permits and Inspections 8 Building Code Information 9 Applicable Codes: 9 General Requirements: 9 Contractor s Guidelines 10 Insurance: 11 Architectural Design Criteria 12 Landlord Provided Notes: 13 Storefront Design Criteria 18 Control Zone Criteria 19 Store Interior Design Criteria 20 Storefront Signage Design Criteria 22 Food Court Design Criteria 38 Signage Design Criteria - Food Court 40 Mechanical Design Criteria 43 General HVAC Requirements 44 Electrical Design Criteria 50 Power Service Design Criteria (All Tenants) 51 Plumbing Design Criteria 56 Domestic Water, Sanitary, Vent, Grease and Gas 56 Fire Protection Design Criteria 61 Landlord Supplied Sprinkler System 61 Roofing Criteria 64 Structural Criteria 65 Eastridge Mall

3 Introduction Letter of Introduction This manual has been prepared to assist the Tenant s architect and engineer(s) to prepare drawings and specifications that will meet the Center design criteria. Our objective is to allow the maximum expression of a store s individual personality and character while maintaining a cohesive design theme throughout the Center. The criteria herein are not intended to contradict any code requirements that may govern this project. It is the responsibility of the Tenant s architect, engineers and contractors to comply with all applicable codes. Any questions concerning the information presented in this manual should be brought to the Tenant Coordinator s attention as soon as possible to minimize design revisions. The Tenant Package, ( Print Package ) consists of: Tenant Design Criteria Manual. Lease Outline Drawing (L.O.D.). Tenant As-Builts (if available). Note: This manual is also available on General Growth s website: Locate the mall name under Chose your mall. Click on the Downloadable Information button and select the Tenant Criteria Manual link. Please forward all inquiries, requests, submittals, etc. to: General Growth Properties, Inc. Attn.: Tenant Coordination Department Salt Lake Regional Office 6191 S. State Street Murray, UT Store Name: Space No: Architectural Firm: Contact: Address: Phone: ( ) Fax: ( ) 1 Eastridge Mall

4 Project Directory Center Address: Eastridge Mall Phone: Eastridge Mall Loop, Ste San Jose, CA Landlord: General Growth Properties, Inc. Phone: Attn: Tenant Coordination Department 6191 S. State Street Murray, UT Building Department: Dept. of Planning, Building & Code Development Phone: City of San Jose, California 801 N. First Street, RM 200 San Jose, CA Health Department: City of San Jose, CA Phone: N. First Street RM 200 San Jose, CA Fire Department: City of San Jose, CA Phone: N. First Street RM 200 San Jose, CA Local Utility Agencies Gas & Electric: Pacific Gas & Electric Phone: Water: City of San Jose 200 East Santa Clara Street San Jose, CA Phone: Pacific Bell Phone: P.O. Box Seattle WA Eastridge Mall

5 Landlord Required Contractors Roofing: Clark s Quality Roofing Phone: West Anderson Avenue Murray, UT Sprinklers: Triad Fire Protection Systems, Inc. Phone: Lake Louise Street Fremont, CA Smoke Evacuation System/ Life Safety: Analytical and Construction Services Phone: th Street Los Banos, CA Low Voltage and Data: Tri-County Telephone Phone: Plymouth Drive Gilroy, CA Landlord Contractors landlord s Architect: ELS Architecture & Urban Design 2040 Addison Street Phone: Berkeley, CA landlord s Structural Engineer: Robinson Meier Juilly & Associates 103 Linden Avenue Phone: South San Francisco, CA Eastridge Mall

6 TENANT NAMES SHOWN ON THIS PLAN REPRESENT THOSE LEASES WHICH ARE EXECUTED, OUT FOR SIGNATURE, OR IN NEGOTIATIONS. ALL TENANT LEASE AREAS ARE MEASURED FROM THE CENTERLINE OF INTERIOR PARTITIONS, FROM THE OUTSIDE FACE OF EXTERIOR WALLS, AND FROM THE FULL THICKNESS OF CORRIDOR AND SHAFT WALLS. CERTAIN OF THE ELEMENTS SHOWN ON THE ABOVE PLAN ARE INDICATED AS FUTURE OR PROPOSED, BUT GENERAL GROWTH PROPERTIES, INC. MAKES NO REPRESENTATION THAT THE FUTURE DEVELOPMENT WILL OCCUR AS SHOWN. Lower Level Plan Certain elements shown on this plan are future or proposed. Landlord makes no representation that the future or proposed development will occur as shown. General Growth Properties, Inc. 110 North Wacker Drive Chicago, IL (312) EASTRIDGE MALL 2200 EASTRIDGE LOOP, SUITE 2062 SAN JOSE, CA PROJECT NO: 299 DRAWN BY: NAP COPYRIGHT: General Growth Properties, Inc. DESCRIPTION LOWER LEVEL LEASE PLAN SHEET NO. LP-1 DATE: 08/20/09 4 Eastridge Mall

7 TENANT NAMES SHOWN ON THIS PLAN REPRESENT THOSE LEASES WHICH ARE EXECUTED, OUT FOR SIGNATURE, OR IN NEGOTIATIONS. ALL TENANT LEASE AREAS ARE MEASURED FROM THE CENTERLINE OF INTERIOR PARTITIONS, FROM THE OUTSIDE FACE OF EXTERIOR WALLS, AND FROM THE FULL THICKNESS OF CORRIDOR AND SHAFT WALLS. CERTAIN OF THE ELEMENTS SHOWN ON THE ABOVE PLAN ARE INDICATED AS FUTURE OR PROPOSED, BUT GENERAL GROWTH PROPERTIES, INC. MAKES NO REPRESENTATION THAT THE FUTURE DEVELOPMENT WILL OCCUR AS SHOWN. Upper Level Plan Certain elements shown on this plan are future or proposed. Landlord makes no representation that the future or proposed development will occur as shown. General Growth Properties, Inc. 110 North Wacker Drive Chicago, IL (312) EASTRIDGE MALL 2200 EASTRIDGE LOOP, SUITE 2062 SAN JOSE, CA PROJECT NO: 299 DRAWN BY: NAP COPYRIGHT: General Growth Properties, Inc. DESCRIPTION UPPER LEVEL LEASE PLAN SHEET NO. LP-2 DATE: 08/20/09 5 Eastridge Mall

8 Site Plan General Growth Properties, Inc. 110 North Wacker Drive Chicago, IL (312) TENANT NAMES SHOWN ON THIS PLAN REPRESENT THOSE LEASES WHICH ARE EXECUTED, OUT FOR SIGNATURE, OR IN NEGOTIATIONS. ALL TENANT LEASE AREAS ARE MEASURED FROM THE CENTERLINE OF INTERIOR PARTITIONS, FROM THE OUTSIDE FACE OF EXTERIOR WALLS, AND FROM THE FULL THICKNESS OF CORRIDOR AND SHAFT WALLS. CERTAIN OF THE ELEMENTS SHOWN ON THE ABOVE PLAN ARE INDICATED AS FUTURE OR PROPOSED, BUT GENERAL GROWTH PROPERTIES, INC. MAKES NO REPRESENTATION THAT THE FUTURE DEVELOPMENT WILL OCCUR AS SHOWN. EASTRIDGE MALL 2200 EASTRIDGE LOOP, SUITE 2062 SAN JOSE, CA PROJECT NO: 299 DRAWN BY: NAP COPYRIGHT: General Growth Properties, Inc. DESCRIPTION SITE PLAN SHEET NO. SP-1 DATE: 09/03/09 6 Eastridge Mall

9 Tenant Submissions and Permit Requirements Document Submission Please keep in mind that submission of plans must be in accordance with the time schedule specified in the lease. Sufficient time must be allowed for Landlord s and Local Jurisdiction reviews and approval processes. Preliminary Landlord plan approval will take approximately 5 working days or less. Final Landlord plan approval will take approximately 10 working days or less. The failure to provide adequate information during any phase will be just cause for return of the submission with no review. The submission at the preliminary phase must be complete in order to fairly evaluate the proposal and to also prevent continuation of work on an unacceptable storefront design. Previously Improved Spaces At previously improved spaces, Tenant accepts the Leased Premises in an as is condition and shall fully remodel the storefront and interior of their store. No Existing material or finishes may be reused without Landlord s approval. Said remodeling shall consist of architectural, plumbing, fire protection, mechanical and electrical work. Tenant shall be responsible for the demolition and removal of any and all existing equipment and finishes related to the Premises at the Tenant s sole expense. The Landlord may furnish the Tenant with existing drawings for a previously occupied space or with a lease outline drawing only. In either case, the Tenant shall be responsible for verifying all existing conditions and dimensions. The Landlord does not represent to the Tenant that previous Tenant documents reflect as-built conditions. The Tenant and his/her Architect should become totally familiar with the information package and the existing condition of the premises before proceeding to the Design Phase. The Landlord is not responsible for errors due to the lack of field verification by the Tenant. Typically, the Tenant will be required to perform a complete remodel of the Premises. Complete remodel consists of the removal and replacement of all improvement beyond the Landlord s base building. Preliminary Documents: Two bond sets indicating: Key plan. Floor plan. Storefront elevation. Reflected ceiling plan. Material sample board (labeled and keyed to plan). Color rendering or photograph of storefront prototype. 7 Eastridge Mall

10 Final Construction Documents: Submit drawings electronically directly to the Tenant Coordinator. If you are unable to submit via , FTP Site, or as PDF. files on disc please contact your Tenant Coordinator. Construction documents containing architectural, mechanical, electrical and plumbing drawings. Refer to appropriate section in this manual for drawing requirements. Note: After Landlord approval, any changes or modifications to the construction documents or Tenant s interior improvements must be approved by Landlord in writing. Sprinkler Documents: Verify procedure and requirements for sprinkler drawings and modification with the Landlord s on-site representative. Drawings and hydraulic calculations must be sealed and signed by a registered fire protection engineer from the State. Sprinkler contractor is required to submit sprinkler shop drawings to Landlord s on-site representative. Hood Documents: Verify with Landlord s on-site representative for food related Tenants the requirements for hood submission. Signage Documents: Submit drawings electronically directly to the Tenant Coordinator. Signage shop drawings. Blade sign shop drawings Required Permits and Inspections Permits required by the Local Jurisdiction must be presented to the Landlord s on-site representative prior to work start. It is the responsibility of the Tenant to obtain the approved construction documents from the Local Jurisdiction and to pay for and secure all applicable permits. Note: All interior Tenant store signage shall be submitted to Landlord for approval. Exterior building store signage will require both Landlord s and the Local Jurisdiction s approval. Inspections: It is the Tenant architect s or contractor s responsibility to verify the field inspections required by the Local Jurisdiction. 8 Eastridge Mall

11 Building Code Information It is the sole responsibility of the Tenant s architect, engineer(s) and contractor(s) to comply with all applicable Federal, State, Local codes and ordinances for their occupancy type. Building Type: Building Type Type II-1 hour construction, 2 Story regional mall. Applicable Codes: Building Mechanical Plumbing Electrical Fire Accesibility Food Code Energy Code Building Permit Requirements 2001 California Building Code 2001 California Mechanical Code 2001 California Mechanical Code 2001 California Electrical Code 2001 California Fire Code 1997 Code for Building Conservancy, Chapter 5, Appendix 1,5,** Verify with Local City Building Department ADA Verify with Local City Building Department 2003 International Energy Conservation Code (IECC) Verify with Local City Building Department General Requirements: The Tenant shall cause its general contractor to deposit with Landlord s on-site representative without liability for interest, the sum of $5, This sum shall be applied towards any costs incurred by the Landlord or the Landlord s contractor to complete any part of the Tenant s work including but not limited to punch list items and damage caused to any portion of the mall which the Tenant or the Tenant s contractor fails to complete within the time period required by the lease. A certified check made payable to General Growth Properties must be submitted to Landlord s on site representative prior to work start. The Tenant s contractor shall erect at the Landlord s option, a 13-0 high (minimum) barricade (as outlined in the barricade detail attached) to serve the Tenant s area at the Tenant s expense. This barricade can extend into the mall area 3-0 only when working on the storefront. All material must be kept within the leased area. No storage of equipment or material are to be kept in unoccupied spaces, corridors, mall property or parking lot areas. All construction access is through the rear of the Tenant s space. All materials and workman access must be delivered to and brought into the building through the Tenant Contractor designated loading dock(s) and service corridors. Landlord s on-site representative will designate approved loading docks, service corridors, acceptable delivery/usage times, dumpster access, etc. No materials, assemblies, deliveries or workman access is permitted through the Tenant s storefront or in the mall common areas at any time. 9 Eastridge Mall

12 Contractor s Guidelines The following is a brief description of required items/procedures for Tenant construction. Note that this is not a complete description of all requirements and limitations for Tenant construction. The Tenant s contractor shall obtain a Tenant s Contractor Manual at the site from an authorized GGP representative for further guidelines. Quality Standards: All work by the Tenant s contractor, including repair work, shall be performed in a first-class workmanlike manner and shall be in a good and usable condition at completion. The Tenant shall require any person performing work to guarantee that the work is free from any and all defects in workmanship and materials for 1 year from the date of completion. The Tenant shall also require any such person to be responsible for the replacement or repair without additional charge of work done or furnished by or through such person which shall become defective within 1 year after substantial completion of the work. The correction of work shall include, without additional charge, all expenses and damages in connection with the removal, replacement or repair of any part of work which may be damaged or disturbed. All warranties or guarantees for materials or workmanship on or regarding the Tenant s work shall be contained in the contract or subcontract. The contract shall be written so that all warranties and guarantees shall inure to the benefit of both the Landlord and the Tenant, as their respective interests appear, and so that the contract can be directly enforced by either party. Coordination: The Tenant s work shall be coordinated with the Landlord s work as well as with the work of other Tenants in the shopping center, so that the Tenant s work will not interfere with or delay the completion of other construction in the shopping center. Construction Trash Removal: Tenant and Tenant s contractor(s) are responsible for all trash removal during construction, fixturing and stocking. Trash removal shall be performed using the containers, dumpsters, loading docks and service corridors as designated by Landlord s on site representative. All trash removal shall be performed during the days and times as designated by Landlord. Trash accumulation shall not be permitted overnight in the Leased Premises, mall common areas or service corridors. In the event Landlord provides trash removal at Tenant s request or as a result of Tenant s or Tenant s contractor s failure to remove trash, then Tenant and Tenant s contractor shall reimburse Landlord for its costs. Temporary Electric: Landlord may provide temporary electrical service in designated areas of the mall during construction. Tenant shall request, in writing, permission to connect to the temporary service and distribute temporary service to the Leased Premises in accordance with applicable code and as designated by Landlord s on site representative. 10 Eastridge Mall

13 Other Contractor Requirements: Tenant and Tenant s contractor shall not commence any work or deliver any materials to the building or site without conducting a pre-construction meeting with Landlord s on-site representative and supplying all required pre-construction documents. Documents shall include but not limited to, a copy of building permit, certificate of insurance, contractor s license, construction schedule and subcontractor list. Tenant shall ensure that all Tenant contractors are bondable and licensed in the State and City of the location of the mall. Landlord shall have the right to approve Tenant s contractors and subcontractors; however, such approval shall not constitute the assumption of any responsibility or liability by Landlord for the actions of Tenant s contractors or subcontractors or the quality or sufficiency of Tenant s Work. All materials, supplies and labor necessary for the construction, fixturing or merchandising of the Tenant s premises must be delivered at the times and through the designated truck docks and service corridors as designated by Landlord s on site representative. Tenant s contractor(s) may perform noisy construction, such as jack hammering, saw cutting, core drilling, etc., only during the hours as designated by the Landlord s on site representative. Tenant s contractor shall obtain Landlord s prior written approval for all drilling, welding or other attachment to Landlord s structural system. Tenant s contractor s work shall be subject to inspection by Landlord during the course of construction for the purpose of determining the quality of the workmanship and adherence to Landlord requirements. Tenant s contractor is required to cooperate with Landlord s on site representative and correct any deficiencies noted within 10 days. All work performed by Tenant s contractor shall be performed in strict accordance with the Landlord approved final plans and mall requirements. Insurance: The Tenant s contractor must fulfill the following insurance requirements, and shall maintain at no expense to the Landlord : Workers Compensation Insurance with statutory limits and Employer s Liability Insurance with limits of not less than $100,000 General Liability Insurance with limits of not less than $2,000,000 combined single limit for bodily injury and property damage, including personal injury, Contractual Liability Coverage specifically endorsed to cover the indemnity provisions contained herein and Contractor s Protective Liability Coverage if the contractor uses subcontractors Motor Vehicle Liability Insurance in the contractor s name, including owned, non-owned, leased and hired car coverage with limits of not less than $2,000,000 combined single limit per occurrence for bodily injury and property damage 11 Eastridge Mall

14 All Tenants Architectural Design Criteria The following is a list of minimum design information required to expedite plan approval by Landlord. It is not intended to be a complete listing of all requirements, but should serve as a minimum checklist to be used by Tenant s design consultants to complete the construction documents. We urge you to read this manual in its entirety in order to fully understand the requirements needed to generate an acceptable set of construction documents. Architectural Drawing Requirements All Sheets: Tenant space number to be shown in the title block. Drawings to show column lines with designations. Cover Sheet: Tenant name. Project directory. Location plan with space number. Leased square footage. Architectural symbols list. Drawing list. Occupancy load. Building data, use and construction type. Flame spread ratings of materials (as per code). Landlord provided notes. Floor Plans (1/4 scale min.): Demising and interior partition wall locations dimensioned. Indicate base building columns lines on drawings. Restroom facilities. Location of fixtures and equipment. Recessed service door (if applicable). ADA path of egress indicated. Door and room finish schedules. Typical wall sections. Storefront Interior Elevations and Details: Storefront entry elevation. Interior store elevations. Identification of finishes and colors. Longitudinal and typical section through storefront from slab to roof. Typical section through demising walls. Storefront signage. Blade signage (if applicable). Neutral pier and bulkhead details. Floor transition details. 12 Eastridge Mall

15 All Tenants Reflected Ceiling Plan: Ceiling heights. Identification of ceiling materials. Exit lights. Emergency lights. Light fixtures. Sprinkler heads. Air diffusers and grilles. Access panels. Signage Drawing Requirements Incorporate signage into storefront elevation. Indicate letter height. Provide typical letter section. Method of wiring and mounting. Indicate color and materials. Blade sign (if applicable). Landlord Provided Notes: The following Landlord notes must appear on the cover sheet of all Tenant s final construction documents: Tenant s general contractor shall submit a construction deposit with Landlord s on-site representative per Center requirements. Tenant s general contractor must check in with Landlord s on-site representative prior to work start. Tenant s contractor will repaint and/ or repair Landlord s property, (neutral piers, bulkheads, rear corridor, etc.) damaged during Tenant improvement. All ceiling material must have a minimum of a class A fire rating. Support wires for lay-in ceiling grid, lights HVAC equipment, etc. must not be connected to any of Landlord s electrical, plumbing, fire protection piping and mechanical equipment or deck above. All support wires may only be connected to top cord of joist and/ or structural members. All materials used in the construction of this space must be asbestos free. Food related Tenants and upper level Tenant s with bathrooms shall provide a water proof membrane in wet areas. Verify water test procedure with Landlord s on-site representative. Do not channel cut slab on upper level. Core drill only and install supplemental support framing. Any penetration or modifications to structural steel or concrete must be coordinated and approved by Landlord s on-site representative. It is the responsibility of the Tenant s architect to field verify dimensions, utility locations and conditions prior and during construction. Tenant shall not penetrate Landlord s metal roof deck with any type fasteners. It is Tenant s responsibility to maintain the integrity of Landlord s demising walls, floor slab, roof and building structure. Tenant to remove any existing or newly abandoned materials, equipment, piping, ducts and wiring from the premises. Cap service at point of origin and coordinate this work with Landlord s on-site representative. 13 Eastridge Mall

16 Landlord Provided Notes (continued): Tenant must comply with Title III of the Americans with Disabilities Act (ADA) and all Local and State codes. Free standing security devices are not allowed in the control zone. Security devices shall be concealed from public view. Tenant is to maintain any expansion joints within their leasable area. Install cover plates per Center requirements. Television antennas and satellite dishes are not permitted on the roof or attached to HVAC units. Tenants requiring cable television should refer to their lease and contact the Landlord s on-site representative for additional information. Tenant s storefronts must be self supported from the floor. Attachment to the Landlords structure above is allowed for lateral bracing only. The water meter, to be read in gallons for all Tenants, to be located in service corridor accessible to the Landlord. The water meter must be easily readable. Tenant s must comply with all seismic requirements for the State of California and the City of San Jose. PVC is not permitted above grade in any type of application. All reused material and equipment must be refurbished to like new condition. LANDLORD SUPPLIED ARCHITECTURAL ITEMS Neutral Pier: The neutral pier will be a 1 deep, 6 wide black anodized aluminum channel. Corridors: Tenant must install a 1 hour fire rated corridor through storage/stockrooms. Demising Wall Studs: 6, 22 gauge metal 24 on center to deck, provided at the centerline of all demising and corridor walls. ROOF STRUCTURE: There are currently three roofing systems: 1. Poured gypsum concrete over form board 2. Light weight structural concrete on metal deck 3. Unfilled metal deck FLOOR SLABS: Lower Level: (existing in most cases) 4 slab on grade at 2500 PSI concrete at 28 days, (N.W.C) * allowable live load 100# SP note: Saw cutting is allowed at a minimum (lower level only) upon Landlord s approval. Upper Level: 3 1/2 reinforced concrete slab over pan joist at 36 on center. *allowable live load 100PSF. One hour rated. STRUCTURAL FRAME: Landlord may provide a 1 hour rated structural frame. Tenant is responsible to patch spray fireproofing at steel columns and beams, if damaged, at Tenant s expense. Tenant shall use approved material that does not contain any hazardous materials. Note: Tenants providing HVAC equipment, safes, any equipment over 1,000 lbs. or roof mounted equipment over 400 lbs that is not supported by Landlord provided equipment rails will require Landlord structural engineers review and approval at tenant s expense. Any additional steel reinforcement to the structure shall be fabricated and installed at Tenant s expense. Additionally, any in floor security systems shall be reviewed and approved by the Landlord s approved structural engineer at Tenants cost and expense prior to installation. 14 Eastridge Mall

17 All Tenants The following criteria are provided to give the Tenant maximum design flexibility while maintaining a consistent and high quality retail environment at the Center. This criteria will guide the Tenant s designer to create a store design compatible with the overall design intent of the Center. All storefront, interior designs and materials are subject to Landlord s approval. It should be understood that Landlord will review a Tenant design concept with neighboring Tenants and make judgments that will benefit the entire Center. General Tenant Design Constraints: Landlord may provide a minimum 12-0 height clearance throughout Tenants space, except in zone A. Additional height may be achieved upon Landlord s written approval. Any alterations to Landlord s structure or utilities as a result of ceiling height increase shall be at Tenant s expense. Tenant s storefront must be self supported. Storefronts shall not be suspended from Center bulkhead. Wood blocking, decking and framing may be permitted (subject to building department review/approval) below the ceiling line and must be stamped fire retardant. (all raised platforms shall be constructed of noncombustible materials.) No combustibles above ceiling (i.e., transformer, water heaters, etc.). Provide 2 high black vinyl store space number and name, at rear exit door (or approved equal). Provide 2 high black vinyl store space number and name, locate at lower right hand corner of storefront. Waterproof membrane is required for all food related and upper level Tenant s with bathrooms. All floor penetrations must be sleeved and sealed liquid tight. Do not channel slab on upper level. Core drill only and install supplemental support framing as required. Support wires for lay-in ceiling grid, lights, HVAC equipment, etc. must not be connected to any of Landlord s mechanical, electrical plumbing or fire protection piping, equipment or deck above. Support wires must connect to top cord of joist and/ or structural members. Any penetrations or modifications to structural steel or concrete must be coordinated and approved with Landlord s on-site representative and Landlords Structural Engineer. It is the responsibility of the Tenants architect to field check all dimensions, utilities locations and conditions prior to and during construction. Tenant s with second exits are required to install a one hour fire rated corridor. Rolling grille key plates must be concealed from public view and mounted 18 AFF, or per code. Tenant s that are adjacent to service corridors must provide an alcove so that an exit door is fully recessed behind the lease line when in the open position. Tenant must match service corridor finishes established by Landlord throughout corridor side of alcove and provide sprinkler coverage. (see the Architectural Details section of this book). All Tenants are required to have one handicapped accessible toilet, exception may be granted by building department for small tenant spaces. 15 Eastridge Mall

18 Inline Criteria INTERIOR IN-LINE STOREFRONT DESIGN CRITERIA Storefronts shall be designed, fabricated and installed by the Tenant at the Tenant s sole expense. Storefronts shall be predominantly glass and emphasize well-designed architectural elements, a sense of entry and imaginative show window displays. Design elements and detail components must be combined to create an architectural presence. For each facade, a distinctive character should emerge which enhances the Tenant s own image. Store Facade Height: Within Eastridge there are 8 tenant criteria storefront zones with height requirements as follows: Zone A = 9-2 Zone B = 13-0 Zone C = 15-2 Zone D = 19-0 Zone F1 = 13-0 Zone F2 = 13-0 (no projection at this location) Food Court = 10-0 Main Street Scene = Varies Store Facade Planning: (All Tenants) Store facade construction shall not project beyond the lease line, except for approved projecting elements such as entry portals, signage, awnings and canopies. Changes in vertical and horizontal planes must be incorporated into the facade design to create interest and provide visual variety. Flat, straight facades which extend across the entire facade opening will not be permitted. 16 Eastridge Mall

19 Inline Criteria Acceptable Storefront Materials: Glass: Clear tempered with polished and beveled edges. Glass block. Sandblasted or stained glass. Laminates: Corian or equal. Solid core. Wood veneer on solid wood backer, factory applied. Metals: Anodized aluminum. Brass. Bronze. Copper. Electrostatic colors. Stainless steel. Polished, brushed or textured. Tile: Ceramic, mosaic, terra cotta tile. Glass fiber reinforced gypsum. Polished or honed cut stone. Terrazzo. Brick Veneer Wood: Finish grade hard woods painted, stained or sealed. Unacceptable Storefront Materials: Glass: Mirror. Plexiglass. Laminates: Simulated materials: (i.e., brick, stone, wood, etc.). Metals: Antique. Unfinished. Tile: Clay shingles. Simulated masonry and stone. Vinyl tile. Wood: Distressed wood. Masonite. 17 Eastridge Mall

20 Inline Criteria Storefront Design Criteria Decorative design elements such as entry portals, awnings and canopies which add to the character of the store facade are encouraged. All projecting elements shall be designed and constructed with the highest quality standards. Projecting elements shall be designed and located so that they do not create a significant visual barrier to adjacent tenant store facades. Landlord shall have final determination regarding clearance and sight line issues. Storefront facade projecting elements shall comply with the appropriate Zone; refer to Details section to follow. Minimum height to bottom of an overhead projecting element is 9-0. Maximum horizontal projection over the lease line is 12. A maximum of 1/3 of the total storefront width can project over the lease line by 12. No projections can be closer than 3-0 to any neutral pier or center element. Full length storefront width projections are not allowed in any instance. Storefront Entry Criteria For stores which have a store facade width of 30-0 or less, the total entry opening shall not exceed 6-0. For stores which have a store facade width greater than 30-0, the total entry opening width shall not exceed The entry door openings must be divided so that no single opening exceeds 8-0 in width. For stores with more than one facade elevation facing the mall, one entry will be allowed for each distinct store facade elevation which is 20-0 or greater in width. The general opening width restrictions noted above shall apply for each individual elevation. The total combined opening width for all openings shall not exceed Door Closure Requirements Doors shall be fully recessed behind the lease line when in the pen position. Door stops must be flush floor mounted. Door tracks are to be recessed flush with the finished floor. Storefront doors must be equipped with emergency quick release locks as required by Code. Key plates must be concealed from public view. Storefronts and Glazing All storefront glass and glazing shall be tempered, beveled polished edges and shall be set with 1/8 open butt joints between panes. (silicon joint fillers are not permitted) Glass storefront systems that exceed 10-0 in height must be a minimum of 1/2 thick (submit calculations to building department for storefront systems), architectural glazing clips are required. All storefronts, excluding doors, shall have a minimum 4 high approved durable base. (mall tile is recommended) Storefronts are to be self-supporting. (Attachment to the Landlord s structure for lateral bracing only) 18 Eastridge Mall

21 Inline Criteria Control Zone Criteria The front 4-0 area from the storefront lease line has been designated as a control zone area. All Tenants must comply with these requirements. Floors: Provide a smooth and level transition from Tenant s space to common area. Vinyl or rubber transitions are not permitted on the sales area. Provide 4-0 minimum of hard surface transition flooring material past the point of entry. The Tenant must match the mall border tile on the lower level and carpet tile on the upper level from the lease line to the Tenant s storefront line and/or closure line. The Tenants Contractor shall purchase either mall tile or carpet tile at the site from the Landlord s on site representative. Ceilings: Ceiling elevations should vary within the 4-0 control zone. (not to exceed 9-2 ) Locate exit sign behind ceiling soffit so as not to be seen from the center s common area Recessed incandescent downlights shall be used in the control zone. Track type lighting is prohibited unless concealed. Sprinkler heads in the ceiling must be flushed or fully recessed, and the cover plated to be chrome or to match ceiling color. Acoustical tile will not be allowed in the control zone area. Slat wall will not be allowed in the control zone area. 19 Eastridge Mall

22 Inline Criteria Store Interior Design Criteria Tenant s are encouraged to provide a high quality, well detailed and unique interior environment. The interior and storefront design should reflect and compliment one another. The use of quality materials for flooring, walls, ceiling and lighting will accomplish this task. Floors: Tenant is responsible for installing all finished floor coverings. Provide metal terrazzo or butt jointing between all floor material changes Provide waterproof membrane to base height where water is present, (i.e., restrooms) for upper levels Tenant s and all food Tenant s. Ceilings: Furnish and install a ceiling throughout the entire space. Ceiling heights in the Tenant s space shall be a minimum of 9-0 high. All sprinkler heads must be semi-recessed or recessed throughout the sales area. At the upper level, ceilings must be hung from structural steel framing. No attachment to the mall roof deck is allowed Ceiling heights in the Tenant s control zone area shall not exceed 9-2. Lighting: Tenant shall provide lighting for the entire leased premises. Neon will require PK housing through all penetrations. All store cases shall be adequately illuminated and vented. Display window illuminated during Center hours, controlled by a time clock. All store lighting shall be glare free. Flashing, spinning, chasing or strobe lights are prohibited. Note: All tenants must comply with ASHRAE/IES Walls: All Tenants shall provide the required rated gypsum wallboard for their side of the demising wall. All interior wall surfaces accessible or visible to the public must be finished in an appropriate manner using quality materials and finishes. All music, video and pet shops require a minimum 2 sound insulation. 20 Eastridge Mall

23 Inline Criteria Acceptable Store Interior Elements: Hardwoods. Ceramic tile. Natural stones. Metals. Laminates, Corian, etc. Carpet. Gypsum wall board. Concealed spline. 2 x 2 acoustical ceiling system with 3/8 regular edge, non-fissured tile. (2 x 4 scored tile is acceptable). Slatwall. Painted gypsum. 2 x 2 fluorescent fixtures with parabolic lenses. Neon with PK housings through all penetrations. Track lighting cannot to exceed 5 in length. Unacceptable Store Interior Elements: Vinyl and rubber flooring and base are not allowed in sales area. Vinyl and rubber stripping between material floor changes. Unfinished concrete in sales area. Outdoor carpeting. Unfinished metals. 2 x 4 fluorescent fixtures. Prismatic or acrylic lenses. Exposed lighting in sales area. Strobe, spinner, chase, or moving type of lighting. 2 x 4 acoustical ceiling system in sales area. Mirrored ceiling. Note: Some elements are not allowed within the Design Control Zone. Requirements for the Design Control Zone shall take precedence. 21 Eastridge Mall

24 Inline Criteria Storefront Signage Design Criteria Signage is a major visual element to be provided by the Tenant. Imaginative, progressive and creative signage is essential to the success of the Tenants store. All signage are subject to Landlord approval. Landlord reserves the right to disapprove any signage that does not comply with Landlord s criteria. Signage Requirements: Not to exceed 70% of the width of the storefront. Sign height shall not exceed 16 in height and 5 in depth. Limited to Tenant trade name (d.b.a.) only as defined in the lease. Registered trademarks and manufactures labels are not allowed. Signage shall be placed on Tenant s storefront at a minimum of 8-0 A.F.F. Silk-screen signature area maybe applied to the interior surface at 3-0 A.F.F. Verbiage shall be limited to Tenant s name or logo with a maximum letter height of 4. All illuminated signs must be fabricated and installed according to national, local building and electrical codes and must bear UL label. All electrical penetrations through the storefront fascia for sign installation shall use PK housing. Provide access to transformer and local disconnect. A time clock shall control and illuminate Tenant s signage during Center hours. Interior signs that are visible from outside the Tenant s space must be approved by Landlord. All signage must be installed as per code. All wiring, raceways, cabinets, transformers, etc. must be concealed. All lower level Tenants signage must be closed off at the top to eliminate any views of the interior of the sign from above. Neon Requirements: PK Housings required with neon. If exposed neon, paint exposed end of PK to match adjacent surface. Provide clear standoffs. Exposed neon shall be on rheostat dimmer. Use no double backs if possible. If double backs are required, keep to a minimum quantity; paint out to match adjacent surface. Acceptable Sign Types: Fiber optics. Edge lit sandblasted glass. Light boxes if recessed and concealed. Routed backlit letters with translucent face. Dimensional letters of metal, or painted wood. Backlit individual letters pin mounted a maximum of 1 from a non-reflective background. Exposed neon backed by plexiglass as permitted by the Center. Unacceptable Sign Types: Vacuum formed luminous letters. Paper, cardboard, foamcore, cloth and decals. Signs painted directly on Tenant s storefront sign. Animated and flashing lights or lasers. Projecting box or cabinet type signage. High quality individual channel letters. Internally illuminated plexiglass faced channel letters. 22 Eastridge Mall

25 Inline Criteria Storefront Blade Sign Design Criteria Upper level Tenants may be required to have a non-illuminated blade sign at the Landlord s discretion. The Landlord encourages all Tenants to design a unique three dimensional blade sing. The blade sign is to be designed as an integral component of the storefront. All signage is subject to Landlord approval. Signage Requirements: (refer to details section to follow) Tenant shall design, furnish and install the blade sign and bracket. Tenant s name, logo and/ or graphic image. Blade sign to be non-illuminated. Image must be on both sides and right reading on opaque material. Must be of a hard durable opaque material. Maximum signage area shall be 9 square feet. Minimum signage area shall be 4 square feet. Material thickness shall be minimum of 1. The lowest point of the sign shall be at 8-0 A.F.F. Bracket shall extend 4-0 from storefront. All brackets must be structurally designed and mounted to Tenant s storefront by Tenant. Acceptable Sign Types: Wood. Metal. Etched materials. Vitracore or equal. Unacceptable Sign Types: Foamcore. Cardboard. Masonite. Paper. Vacuum formed signage. 23 Eastridge Mall

26 Street Scene Tenants Main Street Scene Design Criteria (exterior) The Tenant stores along the South side of Eastridge create an environment typical of a traditional urban street scene. The pedestrian experience is enhanced by shade elements, sidewalk seating, landscaping and lighting. Architectural characteristics of each of the buildings are unique, and reflect the identity of the Tenant. The result is a variety of complimentary building shapes; styles and heights, such as, may be found along a vibrant downtown retail street. Storefronts are to be articulated by clerestory windows, awnings and other elements evident in town center streets capes. Shade structures such as pergolas, arbors and trellises are encouraged, as are colonnades and recessed entry ways. Exterior Store Facade Heights: (actual storefront heights are subject to local governing codes) A building footprint may be provided by the Landlord and lays out parameters for the extent of the Tenant build out. Each location is subject to unique physical conditions and requirements established by the Landlord. Tenants are offered maximum design flexibility to provide diversity of building forms. The appearance of independently attached building forms in relation to the center are required and provides distinct identity to each Tenant. Vertical expression and architectural interest are required along the storefront line. Storefronts are to be articulated with modulated forms and unique architectural characteristics. Tenants are to provide parapets, mock fenestration, architectural ornamentation or other means to articulate upper facades. Clerestory windows of suggestions thereof, may be utilized to give the illusion of a two-story building. Accessories such as tall fabric metal awnings, glass metal or fabric eyebrow canopies and other forms of shade elements are to be explored. Exterior Street Scene Signage Criteria Exterior signage on building facades plays a vital role in the overall image envisioned for the Eastridge Street Scene. Similar to an urban streetscape, a creative and unique sign for each storefront will provide the diverse identity between the diverse identity between tenants. Location and number of signs are to be presented by Tenant and approved by Landlord. Storefronts with exposed side elevations are to have additional identity as permitted by Landlord and City. Signage types and sign letter sizes are not restricted, allowing creative applications, but Landlord reserves the right to have final approval, in conjunction with required City and Department store approvals. Signage collaboration from one Tenant to the next must be diverse and will be approved on an individual basis. Creative application of signage and logos are required. Layering of materials is encouraged. Tenants may be permitted only one primary sign at main store entries. Secondary sign types may include logos applied to awnings, canvas banners, plaque signs and recessed entry floor signage; subject to Landlord and City approval. Primary signs must be illuminated. Remote types or concealed illumination are encouraged. Exposed neon applied directly to building facades or acrylic-faced channel letters are not permitted. Complete sign packages are to be submitted to Landlord for review and approval. All signs are subject to Landlords Reciprocal Easement Agreement conditions and approvals. All exterior signs must be approved by the City before any installation occurs. 24 Eastridge Mall

27 Architectural Details Neutral Pier Service Demising Wall TENANT LEASE LINE (OUTSIDE FACE OF TENANT'S WALL). WALL C L ROOF STRUCTURE BY LANDLORD MAX. CEILING CLEARANCE HEIGHT VARIES BASED ON EXIST. CONDITIONS. SUSPENDED CEILING BY TENANT. 5/8" TYPE 'X' FIRECODE G.W.B. FULL HEIGHT TO DECK AND SEALED AIR TIGHT BY TENANT. FINISHED FLOOR BY TENANT. TENANT LEASE LINE (CENTERLINE OF DEMISING WALL) 6" METAL 24" O.C. Demising Wall CONCRETE FLOOR SLAB BY TENANT IF NOT EXISTING. MAX. CEILING CLEARANCE HEIGHT VARIES BASED ON EXIST. CONDITIONS. (V.I.F.) SUSPENDED CEILING BY TENANT. 5/8" TYPE 'X' FIRECODE G.W.B. FULL HEIGHT TO DECK AND SEALED AIR TIGHT BY TENANT. FINISH FLOOR BY TENANT. CONCRETE SLAB BY TENANT IF NOT EXISTING. 5/8" TYPE 'X' FIRECODE G.W.B. FULL HEIGHT. 6" METAL 24" O.C. FINISH FLOOR NOTE: TENANT PENETRATIONS IN WALL MUST BE SEALED BY TENANT (IF APPLICABLE). NOTE: TENANT PENETRATIONS IN WALL MUST BE SEALED BY TENANT (IF APPLICABLE). 25 Eastridge Mall

28 Architectural Details Mall Interior Section The above storefront elevation is typical throughout the interior of Eastridge. Only the width and height change in proportion to the appropriate zones. Refer to the following pages for appropriate zone details. 26 Eastridge Mall

29 Architectural Details ZONE A / Mall Interior Zone A Storefront Section Storefront Elevation 27 Eastridge Mall

30 Architectural Details ZONE B / Mall Interior Section Zone B Storefront Section Zone B Storefront Elevation 28 Eastridge Mall

31 Architectural Details ZONE C / Mall Interior Section 29 Eastridge Mall

32 Architectural Details ZONE D / Mall Interior Section 30 Eastridge Mall

33 Architectural Details ZONE F1 / Mall Interior Section 31 Eastridge Mall

34 Architectural Details ZONE F2 / Mall Interior Section Zone F2 does not allow for a projection from the lease line. 32 Eastridge Mall

35 Architectural Details Blade Sign Elevation 33 Eastridge Mall

36 Architectural Details Blade Sign Bracket Detail 34 Eastridge Mall

37 Architectural Details Tenant s Rear Alcove 35 Eastridge Mall

38 Architectural Details Floor Joints 36 Eastridge Mall

39 Architectural Details Typical Floor Transitions 37 Eastridge Mall

40 Food Court Tenants Food Court Design Criteria The food court featuring specialty food Tenants is located on the second level. The Tenants surround the common eating area where tables and seating for approximately 800 people is provided. Skylights above allow natural light to create and open attractive atmosphere. Tenants are encouraged to develop a unique and innovative design and not a traditional franchise look. It is the Landlord s intent that the food court Tenants convey an open market atmosphere and therefore it is important that the Tenant s design shall be compatible with neighboring Tenants. Note: All food court tenants must comply with all health regulations and applicable ordinances of Local Jurisdiction. Control Zone Criteria The front 10-0 are from the food court lease line has been designated as a control zone area. All food court tenants must comply with this criteria. Countertop: The front counter shall have a 2 radius bullnose and be constructed of solid core surfacing material. Recesses in the top counter surfaces (for cash registers, food trays, drink dispensers, etc.) must be set back a minimum of 8 from the front counter. Beverage machines and all other miscellaneous equipment on the front counter are subject to design review. (equipment must be screened and recessed into the countertop, not to exceed 4-0 in height) Sneeze guards shall be architecturally compatible with counter design and in accordance with Code. Provide concealed lighting in counter designs where appropriate. Countertop Materials: Brushed stainless steel. Natural stone (i.e., marble, granite, slate). Glazed ceramic tile. Solid surface (i.e., Corian, Avonite). Wood with clear finish. Laminate countertops are not acceptable Ceiling: Tenant shall provide a nonporous washable ceiling. Painted gypsum wall board, metal or a sealed wood ceiling shall be used in the control zone area. Lay-in ceilings are not acceptable in the control zone area. Ceiling height is control zone area must comply with the Landlord provided section. Lighting: Provide accent lighting at the countertop using recessed incandescent or pendant type fixtures. Provide recessed incandescent fixtures and flush/recessed sprinkler heads within the control zone. 2 x 4 fluorescent lighting is not acceptable in the control zone area. Note: All Tenants must comply with ASHRAE/IES for lighting requirements 38 Eastridge Mall

41 Food Court Tenants Flooring: Provide a ceramic or quarry tile floor with waterproof membrane underlayment and base within the control zone area. Walls: All wall materials shall be washable and nonporous (i.e., epoxy paint, ceramic tile, stainless steel). Provide a food preparation screen wall with service door separating the service and food preparation areas. The Preparation screen wall must be 10-0 from the Tenant s lease line. Service door shall be self-closing to shield the back room from public view. Mirrored walls are not acceptable within control zone area. Menu Board: Menu boards shall be integrated into the overall storefront design. Menu boards shall be recessed or surface mounted onto the preparation screen wall. Menu boards must be illuminated either internally or externally; whichever is best in keeping with the design theme of the store, at Landlords discretion. Store Interior Design Criteria The use of quality materials for flooring, walls, ceiling and lighting is required and are subject to Landlord s approval. Ceiling: Tenant shall provide a nonporous washable ceiling. Acoustic tile. Lighting: Fluorescent type lighting is acceptable. Floors: All materials shall be of a washable nonporous surface. Ceramic or quarry tile floor and base in food preparation area. Provide a waterproof protective membrane turned up to base height throughout entire space. Walls: All wall materials must be washable nonporous (i.e. epoxy paint, ceramic tile or stainless steel) 39 Eastridge Mall

Technical Writing For the Tenant S Architect and Engineer

Technical Writing For the Tenant S Architect and Engineer A r i z o n a C e n t e r P h o e n i x, a r i z o n a TENANT DESIGN CRITERIA GENERAL GROWTH PROPERTIES, INC. 35 CENTURY PARK WAY. SALT LAKE CITY. UT. 84115 Arizona Center The beautiful landscaped gardens

More information

Mall. atthews. atthews. alls. atthews. loouisville. u i s v ille. e n t u cky. entucky. General Growth Properties, Inc. 6-11-2008.

Mall. atthews. atthews. alls. atthews. loouisville. u i s v ille. e n t u cky. entucky. General Growth Properties, Inc. 6-11-2008. Mall M alls Stt.. atthews atthews atthews llouisville,k entucky u i s v ille,k KentucKy e n t u cky loouisville General Growth Properties, Inc. 110 N. Wacker Drive General Growth Properties, Inc. 110 N.

More information

THE BOULEVARD MALL LAS VEGAS, NEVADA

THE BOULEVARD MALL LAS VEGAS, NEVADA THE BOULEVARD MALL LAS VEGAS, NEVADA TENANT DESIGN CRITERIA GENERAL GROWTH PROPERTIES, INC. 35 CENTURY PARK WAY. SALT LAKE CITY. UT. 84115 The Boulevard Mall will embrace our ethnically diverse community

More information

TENANT ARCHITECTURAL DESIGN CRITERIA HANDBOOK #1

TENANT ARCHITECTURAL DESIGN CRITERIA HANDBOOK #1 TENANT ARCHITECTURAL DESIGN CRITERIA HANDBOOK #1 QuickTime and a TIFF (LZW) decompressor are needed to see this picture. Briarwood Mall 100 Briarwood Circle Ann Arbor, Michigan 48108 (734) 769-9610 Briarwood

More information

GENERAL GROWTH PROPERTIES, INC.

GENERAL GROWTH PROPERTIES, INC. T E N A N T C R I T E R I A M A N U A L GENERAL GROWTH PROPERTIES, INC. TUCSON MALL Tucson, Arizona www.shoptucsonmall.com Cover: Architect s rendering of Center Court GENERAL GROWTH PROPERTIES, INC. www.generalgrowth.com

More information

Walmart 4th Wall. Advertising and Lease Line Guidelines. June 2009. Customerexperience

Walmart 4th Wall. Advertising and Lease Line Guidelines. June 2009. Customerexperience Walmart 4th Wall Advertising and Lease Line Guidelines June 2009 Customerexperience Contents Storefront Design Control Zone 1 Unacceptable Sign Types in 5-0 Control Zone 2 Tenant Promotional Signs 3 Hours

More information

GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES

GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES PAGE 13 DESIGN GUIDELINES The following design guidelines have been developed to guide appropriate design in the Downtown

More information

TENANT HANDBOOK Rev. June 27, 2012

TENANT HANDBOOK Rev. June 27, 2012 TENANT HANDBOOK Rev. June 27, 2012 180 East Broad Street Columbus, Ohio 43215 614.621.9000 www.glimcher.com Table of Contents Introduction... 1 Letter of Introduction... 1-1 Location & Site... 2 Site Plan...

More information

CLACKAMAS TOWN CENTER PORTLAND, OREGON

CLACKAMAS TOWN CENTER PORTLAND, OREGON CLACKAMAS TOWN CENTER PORTLAND, OREGON TENANT DESIGN CRITERIA GENERAL GROWTH PROPERTIES, INC. 35 CENTURY 6181 S. PARK StateWAY Street. SALT. Murray LAKE. UT CITY. 84107. UT. 84115 TABLE OF CONTENTS introduction

More information

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components Infrastructure Facility Condition Summary Weighted Avg Condition Score Facility Components Systems Surveyor/ Date Done Comments G Sitework.9 Site Improvements Parking Pedestrian Paving Site Development

More information

17,280 square feet Overview:

17,280 square feet Overview: CENTRAL OFFICE Located at 167 Boston Post Road, East Lyme, Connecticut, the Central Office was built in 1916 as the original Flanders Elementary School and remains connected to the current school. The

More information

Tenant Criteria Manual Architectural

Tenant Criteria Manual Architectural Water Tower Place Tenant Criteria Manual Architectural 835 North Michigan Chicago, IL 60611 September 2008 TABLE OF CONTENTS INTRODUCTION Building Description...1 Tenant Design Criteria Introduction...2

More information

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION

More information

PUBLIC RESTROOMS, DESIGN INTENT

PUBLIC RESTROOMS, DESIGN INTENT PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes

More information

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman. Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal

More information

Natick Mall Tenant Criteria Manual

Natick Mall Tenant Criteria Manual Natick Mall Tenant Criteria Manual Contents Forward... 5 Site Plan... 6 Introduction...7-10 The Site... 7 Arriving at the Retail Center... 8 Entry Level... 8 Upper Level... 9 Avenue and Courts...10 Details,

More information

General Fire Code Requirements Within Commercial Tenant Spaces

General Fire Code Requirements Within Commercial Tenant Spaces FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding

More information

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system

More information

TAX APPRAISAL DISTRICT OF BELL COUNTY STORES & COMMERCIAL IMPROVEMENT CLASSIFICATION GUIDE

TAX APPRAISAL DISTRICT OF BELL COUNTY STORES & COMMERCIAL IMPROVEMENT CLASSIFICATION GUIDE TAX APPRAISAL DISTRICT OF BELL COUNTY STORES & COMMERCIAL IMPROVEMENT CLASSIFICATION GUIDE 1/22/2008 1 STORES & COMMERCIAL BUILDINGS 1. General Construction Class Descriptions 2. Types a. Class A - Fireproofed

More information

Point Auditorium Design Narrative PROJECT NAME: Point Auditorium DATE: 06/25/15 TO: Lance Francis FROM: Leslie Ellsworth

Point Auditorium Design Narrative PROJECT NAME: Point Auditorium DATE: 06/25/15 TO: Lance Francis FROM: Leslie Ellsworth INTRODUCTION: Kronberg Wall Architects is pleased to present the Design Narrative for the Point University Auditorium conversion from the existing warehouse space. General Project Description: This project

More information

INTRODUCTION. Project Directory About the Mall Location Site Plan Lease Plans Document Submission Permits and Inspections ARCHITECTURAL CRITERIA

INTRODUCTION. Project Directory About the Mall Location Site Plan Lease Plans Document Submission Permits and Inspections ARCHITECTURAL CRITERIA TABLE OF CONTENTS INTRODUCTION 1 2 3 5 6 9 11 Project Directory About the Mall Location Site Plan Lease Plans Document Submission Permits and Inspections ARCHITECTURAL CRITERIA 12 13 15 16 22 23 24 24

More information

Gramercy Place Condo Association, Inc.

Gramercy Place Condo Association, Inc. Gramercy Place Condo Association, Inc. UNIT MODIFICATION REQUEST Date of Application: Name of Owner (s): Telephone: (Home) (Cell) E-Mail: Anticipated start date: Anticipated ending date: Permission is

More information

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST 0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL

More information

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY Construction Criteria The unit costs for (Wet) space types are based on the construction quality and design features in the following table. This

More information

Estimating Database Checklist

Estimating Database Checklist Estimating Database Checklist If you are creating a new estimating database for projects, the following list offers a thorough listing of Main and Sub Categories. You can also use it as a checklist to

More information

Certification: Building Plans Examiner. Exam ID: B3

Certification: Building Plans Examiner. Exam ID: B3 Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building

More information

2. What building projects are exempted? (permit not required)

2. What building projects are exempted? (permit not required) BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and

More information

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME) SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME) Construction Criteria The unit costs for ADP Mainframe space types are based on the construction quality and design features in the following

More information

DESIGN GUIDELINES FOR COMMERCIAL, INDUSTRIAL AND MIXED-USE BUILDINGS

DESIGN GUIDELINES FOR COMMERCIAL, INDUSTRIAL AND MIXED-USE BUILDINGS CITY OF CHICAGO DESIGN GUIDELINES FOR COMMERCIAL, INDUSTRIAL AND MIXED-USE BUILDINGS WALL MATERIALS Original wall materials such as brick, stone and terra cotta should be repaired and maintained. Dry-vit

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT SAMPLE SCHEDULE OF S 1.00 General Conditions 1.01 Project Management 1.02 General Superintendent 1.03 Superintendents 1.04 Safety Engineer 1.05 Scheduling 1.06 Field Engineering 1.07 Bonds 1.08 Trailer

More information

Building Code Clarifications - 7. Fire Resistance

Building Code Clarifications - 7. Fire Resistance Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,

More information

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

Industrial Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Industrial Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations 16.20.110 - Industrial Suburban District ( IS ) Figure REFERENCE Typical Buildings in the IS District Figure REFERENCE Site Plan of a typical development in the IS District Sections: 16.20.110.1 Composition

More information

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities Division 1 Requirements Design and Construction Quality Campus Master Plans Texas Tech University System Operating and Building Maintenance Project Administration Historically Underutilized Business (HUB)

More information

Saint Cloud Business Center

Saint Cloud Business Center Saint Cloud Business Center 14 7th Avenue North Saint Cloud, MN 56303 For Sale Located on 7th Avenue in the heart of downtown across from the Court House Square. A large professional reception area with

More information

THIRD LAGUNA HILLS MUTUAL

THIRD LAGUNA HILLS MUTUAL THIRD LAGUNA HILLS MUTUAL SECTION 34 WINDOWS & WINDOW ATTACHMENTS MAY 1996, RESOLUTION M3-96-28 SEPTEMBER 2002, RESOLUTION M3-02-47 NOVEMBER 2002, RESOLUTION M3-02-62 OCTOBER 2004, RESOLUTION 03-04-27

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are: When is a Permit Required? The most common types of projects that require permits are: -New Houses or buildings -Room Additions or Expansions -Structural repairs, remodeling and alterations -Accessory

More information

Building Condition Assessment Report

Building Condition Assessment Report C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses

More information

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 SECTION B1: PREPARATION GUIDE B1.1 INTRODUCTION... B1-1

More information

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS Los Angeles, CA Project Manual and Specification DIVISION 1 GENERAL CONDITIONS 01 01 10 STATEMENT OF WORK 01 11 00 SUMMARY OF THE WORK 01 14 05 METRO (OWNER) - DIRECTED STOPPAGES 01 20 00 PRICE AND PAYMENT

More information

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES Department of Health and Human Services, Division of Public Health Occupational and Environmental Epidemiology Branch 1912 Mail Service Center, Raleigh, North Carolina 27699-1912 BUILDING ASSESSMENT QUESTIONNAIRE

More information

29 Broadway- 14 th Fl Tel: 212.888.8334 New York NY 10006 Fax: 212.419.1939. Due Diligence Report. New York, New York

29 Broadway- 14 th Fl Tel: 212.888.8334 New York NY 10006 Fax: 212.419.1939. Due Diligence Report. New York, New York Due Diligence Report New York, New York Prepared for Mr. On February 8, 2010 P a g e 1 Table of Contents PAGE 3.. GENERAL INFORMATION PAGE 4 FILINGS PERMITS AND ENCUMBRANCES PAGE 6. CORE AND SHELL PAGE

More information

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No. Classification: Cluster: Location: Total Area: No. of Stories Aquarium Acreage Owned: Acquired: 1904 Most Recent Improvements: THE AQUARIUM Close to junction of Inselrhue and Loiter Way, Belle Isle Two

More information

SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST

SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST SODA SPRINGS HIGH SCHOOL REPAIRS AND UPGRADES SITE Construction Estimate = $100,000

More information

Physical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone:

Physical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone: Choctaw Date Recorded: Permit # RESIDENTIAL - BUILDING Permit APPLICATION Physical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone: YES NO Sec., Township, Range/Subdivision: Acres/Block:

More information

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 16050 A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1

More information

D Sample Notices to Property Owners, Sample Affidavits, and Other Material

D Sample Notices to Property Owners, Sample Affidavits, and Other Material D Sample Notices to Property Owners, Sample Affidavits, and Other Material These samples are offered to illustrate specific points in the Desk Reference. States and communities should examine them carefully

More information

DESIGN REVIEW CHECKLIST Chapter 6 Special Consideration Design Guidelines

DESIGN REVIEW CHECKLIST Chapter 6 Special Consideration Design Guidelines DESIGN REVIEW CHECKLIST Chapter 6 Special Consideration Design Guidelines A. Offices a. Office buildings should be built to the minimum required setback. b. Surface parking should be located towards the

More information

Building Condition Assessment Report

Building Condition Assessment Report Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.

More information

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS Permit applicants shall submit three (3) COMPLETE SETS of plans and specifications with each application for a permit. Plans and specifications

More information

RULES AND REGULATIONS CONTRACTOR WORK

RULES AND REGULATIONS CONTRACTOR WORK RULES AND REGULATIONS CONTRACTOR WORK CARILLON 227 West Trade Street Suite 330 Charlotte, NC 28202 The following Rules and Regulations shall govern the operation of contractor work in the Building. For

More information

SECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request

SECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request SECTION 00 0110 PROCUREMENT AND CONTRACTING REQUIREMENTS 1.1 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS A. 00 0101 - Project Title Page B. 00 0105 - Certifications Page C. 00 0110 - Table

More information

The City of Basehor, Kansas

The City of Basehor, Kansas The City of Basehor, Kansas Residential and Miscellaneous Permits This list provides general information regarding permit requirements for various residential construction and maintenance activities. The

More information

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST CITY OF BERKELEY DETAILED CHECKLIST This checklist will assist you in preparing plans for submittal with a building permit application. Alterations, additions and remodeling projects may not require all

More information

COMMUNITY APPEARANCE STANDARDS

COMMUNITY APPEARANCE STANDARDS Article 25 COMMUNITY APPEARANCE STANDARDS 25.01 Applicability 25.01.01 This Article is applicable to the publicly visible portions of building elements, as defined herein. A. An element of a building shall

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

Slavic Village Building Condition Review

Slavic Village Building Condition Review Slavic Village Building Condition Review Slavic Village Development May 8, 2015 Page 1 EXECUTIVE SUMMARY City Architecture was commissioned by Slavic Village Development to review five existing facilities

More information

ST. MONICA FOOD PANTRY HOUSTON, TEXAS

ST. MONICA FOOD PANTRY HOUSTON, TEXAS PROJECT MANUAL FOR ST. MONICA FOOD PANTRY HOUSTON, TEXAS OWNER: ST. MONICA CATHOLIC CHURCH 8421 W. MONTGOMERY ROAD HOUSTON, TEXAS 77088 ARCHITECT: C SIX ARCHITECTURE, LLC 4606 F.M. 1960 WEST, STE 400 HOUSTON,

More information

Contractors Rules & Regulations

Contractors Rules & Regulations Contractors Rules & Regulations November 2, 2015 (1) Pre-Construction Meeting Pg. 2 (2) Permits and Licensing Pg. 3 (3) Union Affiliated Guidelines Pg. 4 (4) Temporary Provisions Pg. 5 (5) Construction

More information

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS St. Louis County Department of Public Works Division of Code Enforcement KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the

More information

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included

More information

Sample Drawing Package for One and Two Family Dwelling Applications

Sample Drawing Package for One and Two Family Dwelling Applications Sample Drawing Package for One and Two Family Dwelling Applications For a full list of submission requirements, refer to the relevant checklist for your application found on our website: http://vancouver.ca/home-property-development/application-forms-and-checklists.aspx

More information

CLEAR-DIVISIONS VARIOFOLD

CLEAR-DIVISIONS VARIOFOLD CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the

More information

WOODLANDS MALL EXPANSION

WOODLANDS MALL EXPANSION WOODLANDS MALL EXPANSION Tenant Design Criteria PAGE 2 Table of Contents Part A - Woodlands Mall Expansion - Lifestyle Center Architectural Design Criteria Page Introduction 3 Section 1: Architectural

More information

TENANT DESIGN MANUAL UPDATED JULY 2015

TENANT DESIGN MANUAL UPDATED JULY 2015 TENANT DESIGN MANUAL UPDATED JULY 2015 PROJECT OVERVIEW Grapevine Mills is located at the interchange of SR 121 and Grapevine Mills Parkway. It is centrally located just 20 miles northwest of Dallas and

More information

Inspecting to a higher standard.

Inspecting to a higher standard. Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com rob@protec-inspections.com

More information

Facility Assessment for. 11801 East Main Street, Huntley, IL

Facility Assessment for. 11801 East Main Street, Huntley, IL Facility Assessment for 11801 East Main Street, Huntley, IL July 12, 2012 Prepared by: Dewberry Architects Inc. 25 S. Grove Avenue, Suite 500 Elgin, IL 60120 (847) 695-5840 The Village of Huntley requested

More information

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc. LIFE SAFETY UPDATE FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc. The purpose of this update is as follows: Remind all state

More information

CLEAR-DIVISIONS APERTO

CLEAR-DIVISIONS APERTO CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N PLAN REVIEW FOR: PROJECT NAME: OWNER: ARCH/DESIGNER: ADDRESS: Ph/Fx: Plans Dated: E-mail: Sealed By: Estimated Project Cost - $ REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

Residential Decks. Planning and Development Services Department

Residential Decks. Planning and Development Services Department Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

Article I TENANT S WORK AT TENANT S EXPENSE

Article I TENANT S WORK AT TENANT S EXPENSE Article I TENANT S WORK AT TENANT S EXPENSE Tenant accepts the Premises "as is". Tenant shall complete all work required to place the Premises in a finished condition ready to open for business at the

More information

Packaged Terminal Air Conditioner Wall Sleeve Installation

Packaged Terminal Air Conditioner Wall Sleeve Installation Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation

More information

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C. CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

CITY OF YORBA LINDA P.O. BOX 87014 CALIFORNIA 92885-8714

CITY OF YORBA LINDA P.O. BOX 87014 CALIFORNIA 92885-8714 CITY OF YORBA LINDA P.O. BOX 87014 CALIFORNIA 92885-8714 BUILDING DIVISION (714) 961-7120 Single Family Residential New Construction, Additions & Alterations Submittal Requirements Required agency approvals

More information

UNIQUE LIVE/WORK LOFT

UNIQUE LIVE/WORK LOFT SALES PACKAGE 2625 & 2617 6th Ave. South Birmingham, Alabama UNIQUE LIVE/WORK LOFT building for sale or lease Asking Sales Price: $1,500,000 Asking Rental Rate: $12.00 PSF NNN OFFERED BY Rich Vanchina,

More information

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal. 2.02 DESIGN DEVELOPMENT PHASE GENERAL The Architect shall prepare the Design Development Documents from the approved Schematic Design. The Design Development Documents shall consist of drawings and other

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage

City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage Property Address: Company Name: Contractor Name: Contractor Address: City: State: Zip: License Number: Phone Number

More information

Mark Cramer Inspection Services, Inc.

Mark Cramer Inspection Services, Inc. Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction

More information

Tenant Design Criteria Section a Architectural Design Criteria Updated: July 2015. 3710 Route 9 South, Freehold, NJ 07728

Tenant Design Criteria Section a Architectural Design Criteria Updated: July 2015. 3710 Route 9 South, Freehold, NJ 07728 3710 Route 9 South, Freehold, NJ 07728 TABLE OF CONTENTS ARCHITECTURAL DESIGN CRITERIA General Storefront Requirements Storefront Design Criteria Windows & Glazing Rolling Grille Design Guidelines Awning

More information

HEATING, VENTILATING, AND AIR CONDITIONING EQUIPMENT. Application Guidelines

HEATING, VENTILATING, AND AIR CONDITIONING EQUIPMENT. Application Guidelines HEATING, VENTILATING, AND Application Guidelines The Landmarks Preservation Commission (LPC) is the Mayoral agency charged with designating and regulating individual landmarks and historic districts. The

More information

BUILDING PERMIT SPECIFICATIONS

BUILDING PERMIT SPECIFICATIONS BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide

More information

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME 1 THE BUILDING PROCESS The focus of Woodland Homes building department is Quality, Service and Predictability. Through

More information

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE - The original section of this building was constructed in 1941. The exterior walls are built of good quality stone. In the early 1980 s a similar addition was added to the north elevation. The exterior

More information

Building Permits Permit Counter

Building Permits Permit Counter Building Permits Permit Counter APPLICATION CHECKLIST SUBMITTAL REQUIREMENTS: 1. Completed signed and notarized Development Services Department Permit Application, submit to Permit Counter. 2. Copy of

More information

Metropolis at Metrotown Specialty Leasing Guide 2015

Metropolis at Metrotown Specialty Leasing Guide 2015 Metropolis at Metrotown Specialty Leasing Guide 2015 Metropolis at Metrotown Specialty Leasing 2015 Requirements Thank you for your interest in the Ivanhoé Cambridge Specialty Leasing Program. In order

More information

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein

More information

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

If you are a web registered user of ArlingontPermits.com you may also request an inspection at: TECHNICAL BULLETIN Community Development & Planning, Building Inspections TOPIC: Permits & Inspections for Roofing Replacement Effective November 1, 2011 Revised This Technical Bulletin will provide contractors

More information

Think Of Us First! When It s Time to Distribute Your Plans

Think Of Us First! When It s Time to Distribute Your Plans Think Of Us First! When It s Time to Distribute Your Plans CONSTRUCTION NOTEBOOK WILL LIST YOUR PLANS AND SPECS FREE CALL TODAY FOR DETAILS 702-876-8660 Why use Experience We have over 60 years of experience

More information

Single Family Residential Basement Finish

Single Family Residential Basement Finish How to Use This Guide Building Guide Pottawattamie County Planning & Development Department Building & Safety Division Single Family Residential Basement Finish Provide two (2) sets of plans and complete

More information

Page & Turnbull imagining change in historic environments through design, research, and technology

Page & Turnbull imagining change in historic environments through design, research, and technology DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED

More information

Additions and Alterations

Additions and Alterations Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal

More information