PENTEK S TALON 27XX SERIES RECORDING SYSTEMS

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "PENTEK S TALON 27XX SERIES RECORDING SYSTEMS"

Transcription

1 User s Guide Configuring PMC s Adaptec RAID Controller Page 1 USER S GUIDE PENTEK S TALON 27XX SERIES RECORDING SYSTEMS Configuring PMC s Adaptec RAID Controller Pentek, Inc. One Park Way Upper Saddle River, NJ (201) Copyright 2014 Manual Part Number: xx3 Rev: 1.0 April 17, 2014

2 Page 2 User s Guide Configuring PMC s Adaptec RAID Controller Manual Revision History Date Revision Comments 4/17/ Initial Release Software License Agreement Pentek grants to you a non exclusive, non transferable license to use the object code, source code, example programs and related documentation in this package ( Licensed Materials ) on a single user computer for development of executable runtime code for Pentek products. All Licensed Materials received under a single ReadyFlow Subscription may not be used on more than one computer at the same time or otherwise network the Licensed Materials. Title of the Licensed Materials is not transferred to you by this license. Any sub license, assignment, or other transfer of the Licensed Materials or the rights or obligations of this agreement without prior consent of Pentek is prohibited. Executable runtime code generated through the proper use of the Licensed Materials for execution on Pentek products is not subject to, or restricted by this agreement. Software Limitations Pentek does not warrant that this software will be free from error or meet your specific requirements. You assume complete responsibility for decisions made or actions taken based on information obtained using the programs. Any statements made concerning the utility of the programs are not to be construed as expressed or implied warranties. Pentek makes no warranty, either expressed or implied, including but not limited to, any implied warranties of merchantability and fitness for a particular purpose, regarding the programs and makes the programs available solely on an AS IS basis. Pentek shall not be responsible for incidental or consequential damages. Copyright Copyright 2014, Pentek, Inc. All Rights Reserved. Contents of this publication may not be reproduced in any form without written permission. Trademarks Pentek, SystemFlow, and Talon are trademarks or registered trademarks of Pentek, Inc. Adaptec is a registered trademark of PMC Sierra, Inc. Microsoft, MS DOS, Visual Studio, Windows, and Windows NT are trademarks or registered trademarks of Microsoft Corporation. Printed in the United States of America.

3 User s Guide Configuring PMC s Adaptec RAID Controller Page 3 Table of Contents Page Configuring PMC s Adaptec RAID Controller...5 Configuring the RAID Array...5 Figure 1: Press Control+A...5 Figure 2: Select RAID Controller...5 Figure 3: List of Options...6 Figure 4: Select and Initialize Drives...7 Figure 5: Create Array...7 Figure 6: Select Drives...8 Figure 7: Select the RAID Level...8 Figure 8: Enter an Array Label and the Array Size...9 Figure 9: Set the Stripe Size...10 Figure 10: Set Read Caching...11 Figure 11: Set Write Caching...12 Figure 12: Select Yes Enable Write Cache Always?...12 Figure 13: Select Yes Use Write Cache Without Battery Backup?...13 Figure 14: Select Quick Init...13 Figure 1: SSD Drives Popup Warning...14 Mounting the RAID Array in Windows Figure 16: My Computer Manage...15 Figure 17: Select Disk Management...15 Figure 18: Disk Management Tab...16 Figure 19: Select Partition Style...17 Figure 20: Select New Simple Volume...17 Figure 21: New Simple Volume Wizard...18 Figure 22: Two Physical RAID Arrays...19 Figure 23: Select GPT Partition Style...20 Figure 24: Select New Striped Volume...21 Figure 25: New Striped Volume Wizard...22 Figure 26: Specify Volume Size...23 Figure 27: Select the Drive Volume Letter...24 Figure 28: Format Partition...25 Choosing the RAID Level...27 Rev.: 1.0

4 Page 4 User s Guide Configuring PMC s Adaptec RAID Controller Table of Contents Page This page is intentionally blank Rev.: 1.0

5 User s Guide Configuring PMC s Adaptec RAID Controller Page 5 Configuring PMC s Adaptec RAID Controller To configure PMC s Adaptec RAID controller for use with Pentek s Talon 27xx series of recording systems, you must perform the following two procedures: Configuring the RAID Array (page 5) Mounting the RAID Array in Windows 7 (page 15) Configuring the RAID Array To configure the RAID array using the Adaptec RAID Configuration Utility, follow this procedure: 1) Power on the Talon recorder and press Control+A when prompted as shown in Figure 1. This will force the Talon recorder into the RAID controller BIOS configuration screen. Figure 1: Press Control+A 2) If multiple RAID controllers are installed in your system, each RAID controller must be configured. Select one of these RAID controllers as shown in Figure 2. Figure 2: Select RAID Controller

6 Page 6 User s Guide Configuring PMC s Adaptec RAID Controller Configuring the RAID Array (continued) A list of options will appear, as shown in Figure 3. Figure 3: List of Options 3) Select Initialize Drives.

7 User s Guide Configuring PMC s Adaptec RAID Controller Page 7 Configuring the RAID Array (continued) 4) By pressing the Spacebar, select all the drives that the array will consist of and press Enter to initialize them. See Figure 4. Figure 4: Select and Initialize Drives 5) Select Create Array. See Figure 5. Figure 5: Create Array

8 Page 8 User s Guide Configuring PMC s Adaptec RAID Controller Configuring the RAID Array (continued) 6) Select all of the hard drives that the array will consist of (see Figure 6). Figure 6: Select Drives 7) Select the RAID level (see Figure 7). NOTE: For information about how to choose the RAID level, see Choosing the RAID Level on page 27. Figure 7: Select the RAID Level

9 User s Guide Configuring PMC s Adaptec RAID Controller Page 9 Configuring the RAID Array (continued) 8) Enter an Array Label. See Figure 8. NOTE: The Array Label can be any name you choose. Figure 8: Enter an Array Label and the Array Size 9) Enter the Array Size. NOTE: size is automatically set and should be left unmodified for most configurations.

10 Page 10 User s Guide Configuring PMC s Adaptec RAID Controller Configuring the RAID Array (continued) 10) Set the Stripe Size to the maximum allowable setting. See Figure 9. NOTE: A larger stripe size will result in more efficient data streaming to disk. The maximum stripe size of 1024 KB will provide the most efficient streaming. Figure 9: Set the Stripe Size

11 User s Guide Configuring PMC s Adaptec RAID Controller Page 11 Configuring the RAID Array (continued) 11) Set the Read Caching to Enable. See Figure 10. Figure 10: Set Read Caching

12 Page 12 User s Guide Configuring PMC s Adaptec RAID Controller Configuring the RAID Array (continued) 12) Set the Write Caching to Enable always. See Figure 11. Figure 11: Set Write Caching 13) When prompted, select Yes to acknowledge the risks associated with caching. See Figure 12. array Figure 12: Select Yes Enable Write Cache Always?

13 User s Guide Configuring PMC s Adaptec RAID Controller Page 13 Configuring the RAID Array (continued) 14) When prompted, select Yes to use the write cache without a battery backup. See Figure 13. array Figure 13: Select Yes Use Write Cache Without Battery Backup? 15) Select Quick Init. See Figure 14. Figure 14: Select Quick Init

14 Page 14 User s Guide Configuring PMC s Adaptec RAID Controller Configuring the RAID Array (continued) 16) Select No when prompted to disable all cache settings by the popup message shown below in Figure 1. Figure 1: SSD Drives Popup Warning 17) If multiple RAID controllers are installed on your system, repeat the above steps for each RAID controller, starting with Step 2.

15 User s Guide Configuring PMC s Adaptec RAID Controller Page 15 Mounting the RAID Array in Windows 7 1) Within Windows 7, right click My Computer and navigate to Manage. See Figure 16. Figure 16: My Computer Manage 2) Select Disk Management on the left side of the screen. See Figure 17. Figure 17: Select Disk Management

16 Page 16 User s Guide Configuring PMC s Adaptec RAID Controller Mounting the Array in Windows 7 (continued) Depending on the number of physical RAID controllers installed in your Talon recorder, there are several ways to configure your data drives: In the case of a single physical RAID controller that provides a single data drive volume, perform Step 3 through Step 6. In the case of multiple physical RAID controllers that provide a single data drive volume, skip to Step 7 and perform Step 7 through Step 10. 3) After you select Disk Management, a screen similar to the one shown in Figure 18 will appear. Figure 18: Disk Management Tab

17 User s Guide Configuring PMC s Adaptec RAID Controller Page 17 Mounting the Array in Windows 7 (continued) 4) A popup like the one shown in Figure 19 will appear, asking you which partition style you would like to use. Select the GPT partition style. Figure 19: Select Partition Style 5) Right click on the unallocated space that was created from the RAID controller and select New Simple Volume. See Figure 20. Figure 20: Select New Simple Volume

18 Page 18 User s Guide Configuring PMC s Adaptec RAID Controller Mounting the Array in Windows 7 (continued) 6) Follow the on screen wizard (Figure 21) to create a new drive volume. Figure 21: New Simple Volume Wizard Skip to Step 11 to complete building the single RAID controller data drive.

19 User s Guide Configuring PMC s Adaptec RAID Controller Page 19 Mounting the Array in Windows 7 (continued) 7) If you are using two physical RAID arrays, a screen similar to the one shown in Figure 22 will appear after you select Disk Management. Figure 22: Two Physical RAID Arrays

20 Page 20 User s Guide Configuring PMC s Adaptec RAID Controller Mounting the Array in Windows 7 (continued) 8) A popup, like the one shown in Figure 23, will appear asking you which partition style you would like to use. Select the GPT partition style. Figure 23: Select GPT Partition Style

21 User s Guide Configuring PMC s Adaptec RAID Controller Page 21 Mounting the Array in Windows 7 (continued) 9) Right click on the unallocated space that was created from the RAID controller and select New Striped Volume. See Figure 24. Figure 24: Select New Striped Volume

22 Page 22 User s Guide Configuring PMC s Adaptec RAID Controller Mounting the Array in Windows 7 (continued) 10) Follow the on screen wizard (Figure 25) to create a new drive volume. Figure 25: New Striped Volume Wizard

23 User s Guide Configuring PMC s Adaptec RAID Controller Page 23 Mounting the Array in Windows 7 (continued) 11) Leave the default volume size and click Next. See Figure 26. Figure 26: Specify Volume Size

24 Page 24 User s Guide Configuring PMC s Adaptec RAID Controller Mounting the Array in Windows 7 (continued) 12) Select the drive volume letter. See Figure 27. NOTE: For a single drive volume, the driver letter should be E:\. When building multiple drive volumes, the first drive should start at E:\ and should then continue in alphabetical order. Figure 27: Select the Drive Volume Letter

25 User s Guide Configuring PMC s Adaptec RAID Controller Page 25 Mounting the Array in Windows 7 (continued) 13) Leave the default settings for formatting the drive volume, including Perform a quick format. See Figure 28. Figure 28: Format Partition 14) Complete the process by clicking Finish on the final Wizard screen.

26 Page 26 User s Guide Configuring PMC s Adaptec RAID Controller This page is intentionally blank

27 User s Guide Configuring PMC s Adaptec RAID Controller Page 27 Choosing the RAID Level This section provides a brief overview of the RAID levels supported by your Adaptec RAID controller, including the minimum and maximum number of disk drives required by each. RAID 0 (Non Redundant Array) Stripes data across multiple disk drives. This level offers improved performance but no redundancy. RAID 1 Array Created from two disk drives where one disk drive is a mirror of the other (the same data is stored on each disk drive). This level provides redundancy, but reduced capacity. RAID 1E Array Similar to a RAID 1 array except that data is mirrored and striped, and more disk drives can be included. RAID 5 Array Stripes data for improved performance and uses parity data to provide redundancy. RAID 10 Array Built from two or more equal sized RAID 1 arrays. Stripes and mirrors data across multiple disk drives. This level provides redundancy and improved performance. RAID 50 Array Built from multiple disk drives configured as two or more RAID 5 arrays. Stripes stored data and parity data across all disk drives. RAID 6 Array Similar to a RAID 5 array except that it includes two independent sets of parity data instead of one. RAID 60 Array Similar to a RAID 50 array except that it includes four independent sets of parity data instead of two. Additional information, which is from PMC s Adaptec documentation, is provided in the table on the next page.

28 Page 28 User s Guide Configuring PMC s Adaptec RAID Controller Choosing the RAID Level (continued) RAID Level Redundancy Disk Drive Usage Read Performance Write Performance RAID 0 No 100% *** *** 2 RAID 1 Yes 50% ** ** 2 RAID IE Yes 50% ** ** 3 RAID 10 Yes 50% ** ** 4 RAID 5 Yes 67 94% *** * 3 RAID 5EE Yes 50 88% *** * 4 RAID 50 Yes 67 94% *** * 6 RAID 6 Yes 50 88% ** * 4 RAID 60 Yes 50 88% ** * 8 Minimum Disk Drives Use the above table to select the RAID levels that are most appropriate for the logical drives on your storage space, based on the number of available disk drives and your requirements for performance and reliability Disk drive usage, read performance, and write performance depend on the number of drives in the logical drive. In general, the more drives, the better the performance.

Aberdeen AberNAS 110 RAID Recovery Technical Brief

Aberdeen AberNAS 110 RAID Recovery Technical Brief Aberdeen AberNAS 110 RAID Recovery Technical Brief Aberdeen LLC. Charles D. Jansen Published: February 2005 Abstract This Aberdeen technical brief provides a quick step by step procedure required to repair

More information

SATA RAID SIL 3112 CONTROLLER USER S MANUAL

SATA RAID SIL 3112 CONTROLLER USER S MANUAL SATA RAID SIL 3112 CONTROLLER USER S MANUAL 120410056E1N Copyright Copyright 2003. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system

More information

Promise FastTrak 100-Lite RAID Controller

Promise FastTrak 100-Lite RAID Controller Promise FastTrak 100-Lite RAID Controller User s Manual Version 1.3, November 9, 2001 Copyright Copyright by Promise Technology, Inc. ( Promise ), XP. No part of this manual may be reproduced or transmitted

More information

NVIDIA RAID Installation Guide

NVIDIA RAID Installation Guide NVIDIA RAID Installation Guide 1. NVIDIA BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID. 2 1.2 RAID Configurations Precautions.. 3 1.3 Create Disk Array. 4 2. NVIDIA Windows RAID Installation

More information

2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

2-Bay Raid Sub-System Smart Removable 3.5 SATA Multiple Bay Data Storage Device User's Manual 2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual www.vipower.com Table of Contents 1. How the SteelVine (VPMP-75211R/VPMA-75211R) Operates... 1 1-1 SteelVine

More information

RAID configuration and driver installation guide

RAID configuration and driver installation guide Server systems and motherboards RAID configuration and driver installation guide For AP130-E1 5U Rackmount Server AP1720-E2 5U Rackmount Server NCCH-DL Motherboard PSCH-L Motherboard E1600 First edition

More information

Server Virtualization with QNAP Turbo NAS and Microsoft Hyper-V

Server Virtualization with QNAP Turbo NAS and Microsoft Hyper-V Server Virtualization with QNAP Turbo NAS and Microsoft Hyper-V How to set up the QNAP Turbo NAS as an iscsi storage for Microsoft Hyper-V and as an ISOs repository Copyright 2010. QNAP Systems, Inc. All

More information

RAID OPTION ROM USER MANUAL. Version 1.6

RAID OPTION ROM USER MANUAL. Version 1.6 RAID OPTION ROM USER MANUAL Version 1.6 RAID Option ROM User Manual Copyright 2008 Advanced Micro Devices, Inc. All Rights Reserved. Copyright by Advanced Micro Devices, Inc. (AMD). No part of this manual

More information

Configuring ThinkServer RAID 100 on the TS140 and TS440

Configuring ThinkServer RAID 100 on the TS140 and TS440 Configuring ThinkServer RAID 100 on the TS140 and TS440 Lenovo ThinkServer TS Series Servers Lenovo Enterprise Product Group Version 1.0 September 17, 2013 2013 Lenovo. All rights reserved. LENOVO PROVIDES

More information

Guide to SATA Hard Disks Installation and RAID Configuration

Guide to SATA Hard Disks Installation and RAID Configuration Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation...2 1.1 Serial ATA (SATA) Hard Disks Installation...2 2. Guide to RAID Configurations...3 2.1 Introduction

More information

5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

5-Bay Raid Sub-System Smart Removable 3.5 SATA Multiple Bay Data Storage Device User's Manual 5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual www.vipower.com Table of Contents 1. How the SteelVine (VPMP-75511R/VPMA-75511R) Operates... 1 1-1 SteelVine

More information

Guide to SATA Hard Disks Installation and RAID Configuration

Guide to SATA Hard Disks Installation and RAID Configuration Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation... 2 1.1 Serial ATA (SATA) Hard Disks Installation... 2 2. Guide to RAID Configurations... 3 2.1 Introduction

More information

HP Embedded SATA RAID Controller

HP Embedded SATA RAID Controller HP Embedded SATA RAID Controller User Guide Part number: 391679-002 Second Edition: August 2005 Legal notices Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is

More information

LSI Software RAID Configuration Utility

LSI Software RAID Configuration Utility LSI Software RAID Configuration Utility E8581 First Edition August 2013 Copyright 2013 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in

More information

MANAGING DISK STORAGE

MANAGING DISK STORAGE 1 Chapter 12 MANAGING DISK STORAGE Chapter 12: MANAGING DISK STORAGE 2 CHAPTER OVERVIEW Understand disk-storage concepts and terminology Distinguish between basic and dynamic storage Identify the types

More information

RAID User Guide. Edition. Trademarks V1.0 P/N: 91-187C51GME0-00

RAID User Guide. Edition. Trademarks V1.0 P/N: 91-187C51GME0-00 RAID User Guide Edition V1.0 P/N: 91-187C51GME0-00 Trademarks All brand or product names mentioned are trademarks or registered trademarks of their respective holders. Contents NVIDIA RAID...1 RAID Arrays...1

More information

Guide to SATA Hard Disks Installation and RAID Configuration

Guide to SATA Hard Disks Installation and RAID Configuration Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation... 2 1.1 Serial ATA (SATA) Hard Disks Installation... 2 2. Guide to RAID Configurations... 3 2.1 Introduction

More information

HostRAID. User s Guide

HostRAID. User s Guide R HostRAID User s Guide Copyright 2001-2002 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic,

More information

9243063 Issue 1 EN. Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

9243063 Issue 1 EN. Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation 9243063 Issue 1 EN Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation Nokia 9300i Backing up data Nokia 9300i Backing up data Legal Notice Copyright Nokia 2005. All rights

More information

RAID EzAssist Configuration Utility Quick Configuration Guide

RAID EzAssist Configuration Utility Quick Configuration Guide RAID EzAssist Configuration Utility Quick Configuration Guide DB15-000277-00 First Edition 08P5520 Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation. The

More information

LSI MegaRAID User s Manual

LSI MegaRAID User s Manual LSI MegaRAID User s Manual Q2143 August 2005 Copyright Information No part of this manual, including the products and software described in it,may be reproduced, transmitted, transcribed, stored in a retrieval

More information

Quick Guide to Using your Nokia Phone with Windows 95 Fax - Exchange for Windows 95 or Windows Messaging for Windows 95

Quick Guide to Using your Nokia Phone with Windows 95 Fax - Exchange for Windows 95 or Windows Messaging for Windows 95 Nokia 88xx series and 8210 03.02.00 This Quick Guide is a generic guide for all Nokia 88xx series and 8210 phones. When you are asked to select the modem you will see Nokia ****, please select one of the

More information

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller. Embedded MegaRAID SATA User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter introduces

More information

WebBIOS Configuration Utility Guide

WebBIOS Configuration Utility Guide Dell PowerEdge Expandable RAID Controller 3/QC, 3/DC, 3/DCL and 3/SC WebBIOS Configuration Utility Guide www.dell.com support.dell.com Information in this document is subject to change without notice.

More information

Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM)

Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM) PRIMERGY RX300 S2 Onboard SCSI RAID User s Guide Areas Covered Chapter 1 Features (Overview/Note) This chapter explains the overview of the disk array and features of the SCSI array controller. Chapter

More information

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively. 1. Introduction Onboard-RAID IEI s Onboard-RAID is designed with Promise IDE RAID controller to provide a cost-effective, high performance RAID that adds performance and/or reliability to systems using

More information

HP Embedded SATA RAID Controller

HP Embedded SATA RAID Controller HP Embedded SATA RAID Controller User Guide Part number: 433600-001 First Edition: June 2006 Legal notices Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

hp digital home networking wireless USB network adapter hn210w quick start guide

hp digital home networking wireless USB network adapter hn210w quick start guide hp digital home networking wireless USB network adapter hn210w quick start guide Revision #: 15 Page: 1 of 11 Printed: 08/15/01 04:44 PM The Hewlett-Packard Company makes no warranty of any kind with regard

More information

WORKFLOW INTEGRATOR INSTALLATION GUIDE

WORKFLOW INTEGRATOR INSTALLATION GUIDE WORKFLOW INTEGRATOR INSTALLATION GUIDE Introduction Welcome to Parity Software s Workflow Integrator! Workflow Integrator addresses the business demand for easy to use SharePoint integration as well the

More information

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover JANUARY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind

More information

CRU RTX 800-TR User Manual

CRU RTX 800-TR User Manual CRU RTX 800-TR User Manual Features Supports JBOD and RAID levels 0, 1, 4, 5, 6, and 10 in hardware, with easy configuration using ATTO Technology s RAID management software. CRU TrayFree bays make adding

More information

MetaMorph Microscopy Automation & Image Analysis Software Super-Resolution Module

MetaMorph Microscopy Automation & Image Analysis Software Super-Resolution Module MetaMorph Microscopy Automation & Image Analysis Software Super-Resolution Module Version 7 Installation Instructions July 2013 This document is provided to customers who have purchased Molecular Devices

More information

Virtual Contact Center. Release Notes. Version 7.0.0.18. Revision 1.0

Virtual Contact Center. Release Notes. Version 7.0.0.18. Revision 1.0 Virtual Contact Center Release Notes Version 7.0.0.18 Revision 1.0 Copyright 2012, 8x8, Inc. All rights reserved. This document is provided for information purposes only and the contents hereof are subject

More information

Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines

Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines After all hardware has been installed, you must fi rst confi gure the Intel SATA HostRAID settings

More information

VT8237 SATA RAID User Manual

VT8237 SATA RAID User Manual VT8237 SATA RAID User Manual Enter BIOS Configuration Utility When the system powers on, the following information will appear on screen. Press the Tab key to enter BIOS configuration utility. 39 VIA Technologies,Inc.VIA

More information

PROMISE ARRAY MANAGEMENT (PAM) for

PROMISE ARRAY MANAGEMENT (PAM) for PROMISE ARRAY MANAGEMENT (PAM) for FastTrak SX4030, SX4060 and S150 SX4-M User Manual Version 1.1 PAM for FastTrak SX4030, SX4060 and S150 SX4-M User Manual Copyright 2004 Promise Technology, Inc. All

More information

RAID Manual. Edition. Trademarks V1.0 P/N: 91-187-CK8-A5-0E

RAID Manual. Edition. Trademarks V1.0 P/N: 91-187-CK8-A5-0E RAID Manual Edition V1.0 P/N: 91-187-CK8-A5-0E Trademarks All brand or product names mentioned are trademarks or registered trademarks of their respective holders. Contents NVIDIA RAID... 1 RAID Arrays...

More information

GUID Partition Table (GPT)

GUID Partition Table (GPT) GUID Partition Table (GPT) How to install an Operating System (OS) using the GUID Disk Partition Table (GPT) on an Intel Hardware RAID (HWR) Array under uefi environment. Revision 1.1 April, 2015 Enterprise

More information

HP dx5150 RAID Installation and Setup Guide Version 1.10. Document Part Number: 403571-001

HP dx5150 RAID Installation and Setup Guide Version 1.10. Document Part Number: 403571-001 HP dx5150 RAID Installation and Setup Guide Version 1.10 Document Part Number: 403571-001 July 2005 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

Mylex Online RAID Expansion Enhancement for DACCF Utilities 4.4 and Global Array Manager 2.05. Part Number 771968-D01

Mylex Online RAID Expansion Enhancement for DACCF Utilities 4.4 and Global Array Manager 2.05. Part Number 771968-D01 MORE User Guide Mylex Online RAID Expansion Enhancement for DACCF Utilities 4.4 and Global Array Manager 2.05 Part Number 771968-D01 Copyright 1996 Mylex Corporation. All Rights Reserved. All contents

More information

Serial ATA RAID PCI Card

Serial ATA RAID PCI Card Serial ATA RAID PCI Card User Manual 1 Features Silicon Image SiI3512 SATA controller chip Compliant with PCI Specification, Rev. 2.3 Compliant with Serial ATA 1.0 specification Provides two independent

More information

Remote PC Guide Series - Volume 2b

Remote PC Guide Series - Volume 2b Document Version: 2013-09-06 R720 This guide provides hardware model-specific guidance in server configuration, with BIOS and RAID configuration instructions for the Dell R720. This guide is part of a

More information

Moving a database from MS Access to MS SQL server. Introduction. Selecting the database. Creating a Data Source

Moving a database from MS Access to MS SQL server. Introduction. Selecting the database. Creating a Data Source GO Software Pty Limited Map: 27 Tacoma Blvd, Pasadena SA 5042 Phn: 0403-063-991 Fax: none ABN: 54-008-044-906 ACN: 008-044-906 Eml: support@gosoftware.com.au Web: www.gosoftware.com.au Moving a database

More information

Preface... 1. Introduction... 1 High Availability... 2 Users... 4 Other Resources... 5 Conventions... 5

Preface... 1. Introduction... 1 High Availability... 2 Users... 4 Other Resources... 5 Conventions... 5 Table of Contents Preface.................................................... 1 Introduction............................................................. 1 High Availability.........................................................

More information

NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later

NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later 856-127900-613-G 7th Edition Jun. 2015 Copyright NEC Corporation 2015. Trademarks NEC EXPRESSBUILDER is trademarks of NEC Corporation.

More information

MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement

MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement MaxAttach NAS 4000 Series MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement DOCUMENT OVERVIEW Who Should Use This Instruction Set This MaxAttach NAS 4000 Series by Maxtor HDD Replacement Instruction

More information

Serial ATA RAID PCI. User's Manual

Serial ATA RAID PCI. User's Manual Serial ATA RAID PCI User's Manual Chapter 1 Introduction Table of Contents 1-1 Features and Benefits. 1 1-2 System Requirements. 1 Chapter 2 RAID Arrays 2-1 RAID Overview.. 2 2-1.1 RAID 0 (striping)...

More information

AMD RAID Installation Guide

AMD RAID Installation Guide AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows 7 / 7 64-bit / Vista / Vista 64-bit / XP /

More information

Intel Matrix Storage Console

Intel Matrix Storage Console Intel Matrix Storage Console Reference Content January 2010 Revision 1.0 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE,

More information

This chapter explains how to update device drivers and apply hotfix.

This chapter explains how to update device drivers and apply hotfix. MegaRAID SAS User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter explains an overview

More information

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

SATA RAID Function (Only for chipset Sil3132 used) User s Manual SATA RAID Function (Only for chipset Sil3132 used) User s Manual 12ME-SI3132-001 Table of Contents 1 WELCOME...4 1.1 SATARAID5 FEATURES...4 2 AN INTRODUCTION TO RAID...5 2.1 DISK STRIPING (RAID 0)...5

More information

Secure Perfect RAID Recovery Instructions

Secure Perfect RAID Recovery Instructions Secure Perfect RAID Recovery Instructions Contents Overview Dell PowerEdge 2500 RAID Level 1 Recovery Instructions Overview NOTE If you possess a previous version of this document, you may notice changes

More information

Feith Rules Engine Version 8.1 Install Guide

Feith Rules Engine Version 8.1 Install Guide Feith Rules Engine Version 8.1 Install Guide Feith Rules Engine Version 8.1 Install Guide Copyright 2011 Feith Systems and Software, Inc. All Rights Reserved. No part of this publication may be reproduced,

More information

technical brief Multiple Print Queues

technical brief Multiple Print Queues technical brief in HP Overview HP has the ability to create shared printer queues on a remote machine to help ease the task that administrators face on a regular basis. Print queue creation of the following

More information

AMD RAID Installation Guide

AMD RAID Installation Guide AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows 8 / 8 64-bit / 7 / 7 64-bit / Vista TM / Vista

More information

Microsoft Dynamics GP. Audit Trails

Microsoft Dynamics GP. Audit Trails Microsoft Dynamics GP Audit Trails Copyright Copyright 2007 Microsoft Corporation. All rights reserved. Complying with all applicable copyright laws is the responsibility of the user. Without limiting

More information

White Paper A New RAID Configuration for Rimage Professional 5410N and Producer IV Systems November 2012

White Paper A New RAID Configuration for Rimage Professional 5410N and Producer IV Systems November 2012 White Paper A New RAID Configuration for Rimage November 2012 Combining RAID 5 and RAID 0 to Reduce the Impact of Hard Drive Failures Rimage is changing the hard drive layout and RAID configurations for

More information

Craig Pelkie Bits & Bytes Programming, Inc. craig@web400.com

Craig Pelkie Bits & Bytes Programming, Inc. craig@web400.com Using the Operations Navigator Backup Utility Craig Pelkie Bits & Bytes Programming, Inc. craig@web400.com Edition OPSNAVBACKUP_20020219 Published by Bits & Bytes Programming, Inc. Valley Center, CA 92082

More information

SATARAID5 Serial ATA RAID5 Management Software

SATARAID5 Serial ATA RAID5 Management Software SATARAID5 Serial ATA RAID5 Management Software Home Edition Preliminary Draft Subject to Change Without Notice 05/7/04 Silicon Image, Inc. 1060 East Arques Ave. Sunnyvale CA 94085 (408) 616-4000 www.siliconimage.com

More information

SBI-7125B-T1 Blade Module RAID Setup Procedure

SBI-7125B-T1 Blade Module RAID Setup Procedure SBI-7125B-T1 Blade Module RAID Setup Procedure Revison 1.0 SBI-7125B-T1 Blade Module RAID Setup Procedure The information in this User s Manual has been carefully reviewed and is believed to be accurate.

More information

Virtual Contact Center

Virtual Contact Center Virtual Contact Center MS Dynamics CRM Online Integration Configuration Guide Version 7.1 Revision 1.0 Copyright 2013, 8x8, Inc. All rights reserved. This document is provided for information purposes

More information

WHITE PAPER. HP Guide to System Recovery and Restore

WHITE PAPER. HP Guide to System Recovery and Restore WHITE PAPER January 2003 Prepared By PSG Product Software Engineering Hewlett-Packard Company CONTENTS Purpose3 Using Safe Mode To Diagnose And Correct Problems 4 Using the Recovery Console To Repair Damaged

More information

Intel ESB2 SATA RAID Setup Guidelines

Intel ESB2 SATA RAID Setup Guidelines Intel ESB2 SATA RAID Setup Guidelines Intel ESB2 SATA RAID Setup Guidelines After all the hardware has been installed, you must first configure Intel ESB2 SATA RAID Settings before you install the Windows

More information

BrightStor ARCserve Backup for Windows

BrightStor ARCserve Backup for Windows BrightStor ARCserve Backup for Windows Tape RAID Option Guide r11.5 D01183-1E This documentation and related computer software program (hereinafter referred to as the "Documentation") is for the end user's

More information

Intel Matrix Storage Manager 8.x

Intel Matrix Storage Manager 8.x Intel Matrix Storage Manager 8.x User's Manual January 2009 Revision 1.0 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,

More information

Intel Rapid Storage Technology

Intel Rapid Storage Technology Intel Rapid Storage Technology User Guide August 2011 Revision 1.0 1 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,

More information

Table of Contents. Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2

Table of Contents. Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2 Table of Contents Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2 (1) Installing IDE hard drive(s) in your system... 2 (2) Configuring GigaRAID controller mode and boot sequence

More information

Configuring ThinkServer RAID 100 on the Lenovo TS430

Configuring ThinkServer RAID 100 on the Lenovo TS430 Configuring ThinkServer RAID 100 on the Lenovo TS430 Contents Overview 02 Embedded RAID 100 features on TS430 02 RAID Overview 02 Choosing the RAID Level 02 RAID 0 02 RAID 1 02 RAID 5 03 RAID 10 03 Configuring

More information

Application Note Gemalto Access Client for windows smart card and EFS on Microsoft Windows Vista

Application Note Gemalto Access Client for windows smart card and EFS on Microsoft Windows Vista Application Note Gemalto Access Client for windows smart card and EFS on Microsoft Windows Vista nicolas.bataille@gemalto.com hassen.frikha@gemalto.com November 2007 www.gemalto.com All information herein

More information

Disk management. Learning Objective. Preparing a Disk. Preparation tasks: Initializing the disk, i.e. defining disk s storage structure

Disk management. Learning Objective. Preparing a Disk. Preparation tasks: Initializing the disk, i.e. defining disk s storage structure Disk management (Week 5, Monday 2/5/2007) Abdou Illia, Spring 2007 1 Learning Objective Understand difference between Basic disk Dynamic disk Understand difference between Spanned volume, Striped volume,

More information

Drobo How-To Guide. Topics. What You Will Need. Prerequisites. Deploy Drobo B1200i with Microsoft Hyper-V Clustering

Drobo How-To Guide. Topics. What You Will Need. Prerequisites. Deploy Drobo B1200i with Microsoft Hyper-V Clustering Multipathing I/O (MPIO) enables the use of multiple iscsi ports on a Drobo SAN to provide fault tolerance. MPIO can also boost performance of an application by load balancing traffic across multiple ports.

More information

Adaptec Event Monitor Utility. User s Guide

Adaptec Event Monitor Utility. User s Guide Adaptec Event Monitor Utility User s Guide 2 Copyright Copyright 2013 PMC-Sierra, Inc. All rights reserved. The information in this document is proprietary and confidential to PMC-Sierra, Inc., and for

More information

StarPort iscsi and ATA-over-Ethernet Initiator: Using Mirror (RAID1) disk device

StarPort iscsi and ATA-over-Ethernet Initiator: Using Mirror (RAID1) disk device StarPort iscsi and ATA-over-Ethernet Initiator: Using Mirror (RAID1) disk device www.starwindsoftware.com Copyright 2008-2009. All rights reserved. COPYRIGHT Copyright 2008-2009. All rights reserved. No

More information

DOCUMENTATION LOTUS NOTES BACKUP & RESTORE OPERATIONS

DOCUMENTATION LOTUS NOTES BACKUP & RESTORE OPERATIONS DOCUMENTATION LOTUS NOTES BACKUP & RESTORE OPERATIONS Copyright Notice The use and copying of this product is subject to a license agreement. Any other use is prohibited. No part of this publication may

More information

Monitoring Veeam Backup Server. eg Enterprise v6

Monitoring Veeam Backup Server. eg Enterprise v6 Monitoring Veeam Backup Server eg Enterprise v6 Restricted Rights Legend The information contained in this document is confidential and subject to change without notice. No part of this document may be

More information

Aomei Dynamic Disk Manager Help

Aomei Dynamic Disk Manager Help Aomei Dynamic Disk Manager Help Index How to Resize Volume?...1 How to Add Drive to RAID?...5 How to Remove Drive from RAID?...7 How to Move Volume Slice?...10 How to Resize Volume? The "Resize Volume"

More information

RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card

RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card RAID Utility User Guide Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card Contents 3 RAID Utility User Guide 3 The RAID Utility Window 4 Running RAID Utility

More information

DP-313 Wireless Print Server

DP-313 Wireless Print Server DP-313 Wireless Print Server Quick Installation Guide TCP/IP Printing (LPR for Windows 95/98/Me/2000) Rev. 03 (August, 2001) Copyright Statement Trademarks Copyright 1997 No part of this publication may

More information

Dual msata SSD to 2.5in SATA SSD Converter with RAID

Dual msata SSD to 2.5in SATA SSD Converter with RAID Dual msata SSD to 2.5in SATA SSD Converter with RAID 25SAT22MSAT *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del

More information

New Advanced RAID Level for Today's Larger Storage Capacities: Advanced Data Guarding

New Advanced RAID Level for Today's Larger Storage Capacities: Advanced Data Guarding White Paper October 2000 Prepared by Storage Products Group Compaq Computer Corporation Contents Introduction...2 What customers can expect from Compaq RAID ADG solution...3 RAID ADG Features and Benefits...3

More information

HP StorageWorks Automated Storage Manager User Guide

HP StorageWorks Automated Storage Manager User Guide HP StorageWorks Automated Storage Manager User Guide HP Part Number: 5697-0816 Published: April 2011 Edition: Second Copyright 2010, 2011 Hewlett-Packard Development Company, L.P. Confidential computer

More information

Operating System Installation Guide

Operating System Installation Guide Operating System Installation Guide This guide provides instructions on the following: Installing the Windows Server 2008 operating systems on page 1 Installing the Windows Small Business Server 2011 operating

More information

Redundant Array of Independent Disks (RAID)

Redundant Array of Independent Disks (RAID) For Data Centers Redundant Array of Independent Disks (RAID) Combine and control multiple storage devices for better performance and reliability Application note 2014 Samsung Electronics Co. 1. What is?

More information

-------------------------------------------------------------------- README.TXT

-------------------------------------------------------------------- README.TXT README.TXT Adaptec maxview Storage Manager Adaptec Command Line Interface Utility (ARCCONF) as of December 4, 2012 Please review this file for important information about issues and errata that were discovered

More information

RAID Utility for Windows

RAID Utility for Windows RAID Utility for Windows 1. Enter NVRAIDMAN RAID driver is built in nvidia ALL in one driver provided in our support CD. After you finish the driver installation, you can create, delete, or rebuild any

More information

RAID installation guide for Silicon Image SiI3114

RAID installation guide for Silicon Image SiI3114 RAID installation guide for Silicon Image SiI3114 Contents Contents 2 1 Introduction 4 1.1 About this Guide 4 1.2 The Basics 4 1.2.1 What is RAID? 4 1.2.2 Advantages of RAID 4 1.2.3 Disadvantages of RAID

More information

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual Serial ATA and Parallel ATA Host Controller Rev. 0.96 December 03, 2003 Copyright 2003 ULi Electronics Inc. All rights reserved. COPYRIGHT NOTICE All information in this document is considered ULi Electronics

More information

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2 SATA150 TX2PLUS, TX4 QUICK START GUIDE Version 1.2 SATA150 TX2plus, TX4 Copyright 2002 Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be

More information

HP StorageWorks Automated Storage Manager User Guide

HP StorageWorks Automated Storage Manager User Guide HP StorageWorks Automated Storage Manager User Guide Part Number: 5697 0422 First edition: June 2010 Legal and notice information Copyright 2010, 2010 Hewlett-Packard Development Company, L.P. Confidential

More information

Symantec Enterprise Vault

Symantec Enterprise Vault Symantec Enterprise Vault Guide for Microsoft Outlook 2010/2013 Users 10.0 Full Outlook Add-In Symantec Enterprise Vault: Guide for Microsoft Outlook 2010/2013 Users The software described in this book

More information

COM Port Stress Test

COM Port Stress Test COM Port Stress Test COM Port Stress Test All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording,

More information

Symantec Enterprise Vault

Symantec Enterprise Vault Symantec Enterprise Vault Guide for Microsoft Outlook 2010/2013 Users 10.0 Full Outlook Add-In Symantec Enterprise Vault: Guide for Microsoft Outlook 2010/2013 Users The software described in this book

More information

HP DeskJet 970C Series Printer Network Guide for Windows. English

HP DeskJet 970C Series Printer Network Guide for Windows. English HP DeskJet 970C Series Printer Network Guide for Windows English Table of Contents 1 Using Your Printer on a Network Setting Up Your Printer.......................................................... 2

More information

Installing and Configuring a. SQL Server 2012 Failover Cluster

Installing and Configuring a. SQL Server 2012 Failover Cluster Installing and Configuring a SQL Server 2012 Failover Cluster Edwin M Sarmiento Applies to: SQL Server 2012 SQL Server 2014 P a g e 1 Copyright This document is provided as-is. Information and views expressed

More information

StarWind iscsi SAN Software: Using StarWind with VMware Workstation Virtual Machines

StarWind iscsi SAN Software: Using StarWind with VMware Workstation Virtual Machines StarWind iscsi SAN Software: Using StarWind with VMware Workstation Virtual Machines www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011. All rights reserved.

More information

Symantec Enterprise Vault

Symantec Enterprise Vault Symantec Enterprise Vault Guide for Microsoft Outlook 2010/2013 Users 10.0 Light Outlook Add-In Symantec Enterprise Vault: Guide for Microsoft Outlook 2010/2013 Users The software described in this book

More information

NEC Express5800 Series MegaRAID Storage Manager User's Guide - Windows Edition -

NEC Express5800 Series MegaRAID Storage Manager User's Guide - Windows Edition - NEC Express5800 Series MegaRAID Storage Manager User's Guide - Windows Edition - 7th Edition 12-2006 808-882425-676-G Preface The User's Guide explains the utility MegaRAID Storage Manager to be used for

More information

HP Array Configuration Utility User Guide

HP Array Configuration Utility User Guide HP Array Configuration Utility User Guide January 2006 (First Edition) Part Number 416146-001 Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change

More information

Symantec Enterprise Vault

Symantec Enterprise Vault Symantec Enterprise Vault Guide for Microsoft Outlook 2003/2007 Users 10.0 Full Outlook Add-In Symantec Enterprise Vault: Guide for Microsoft Outlook 2003/2007 Users The software described in this book

More information

Nokia E90 Communicator Backing up data

Nokia E90 Communicator Backing up data Backing up data Nokia E90 Communicator Backing up data Nokia E90 Communicator Backing up data Legal Notice Nokia, Nokia Connecting People, Eseries and E90 Communicator are trademarks or registered trademarks

More information